Cargando…

Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes

Electrode misalignment, produced by mechanical fatigue or bad adjustments of the welding gun, leads to an increase in expulsions, deformations and quality problems of the welding joints. Different studies have focused on evaluations of the influence of a misalignment of the electrodes and the final...

Descripción completa

Detalles Bibliográficos
Autores principales: Ibáñez, Daniel, García, Eduardo, Soret, Jesús, Martos, Julio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9657074/
https://www.ncbi.nlm.nih.gov/pubmed/36366111
http://dx.doi.org/10.3390/s22218412
_version_ 1784829600151371776
author Ibáñez, Daniel
García, Eduardo
Soret, Jesús
Martos, Julio
author_facet Ibáñez, Daniel
García, Eduardo
Soret, Jesús
Martos, Julio
author_sort Ibáñez, Daniel
collection PubMed
description Electrode misalignment, produced by mechanical fatigue or bad adjustments of the welding gun, leads to an increase in expulsions, deformations and quality problems of the welding joints. Different studies have focused on evaluations of the influence of a misalignment of the electrodes and the final quality of the weld nugget. However, few studies have focused on determining a misalignment of the electrodes to avoid problems caused by this defect, especially in industrial environments. In this paper, a method for performing the condition monitoring of electrode alignment degradation was developed following previous research, which has shown the relationship between the misalignment of short-circuited electrodes and the magnetic field generated by them. This method was carried out by means of a device capable of measuring the magnetic field. Finally, an integral system for the detection of misalignments in real production lines is presented. This system set behavior thresholds based on the experimentation, allowing the condition monitoring of the alignment after each welding cycle.
format Online
Article
Text
id pubmed-9657074
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96570742022-11-15 Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes Ibáñez, Daniel García, Eduardo Soret, Jesús Martos, Julio Sensors (Basel) Article Electrode misalignment, produced by mechanical fatigue or bad adjustments of the welding gun, leads to an increase in expulsions, deformations and quality problems of the welding joints. Different studies have focused on evaluations of the influence of a misalignment of the electrodes and the final quality of the weld nugget. However, few studies have focused on determining a misalignment of the electrodes to avoid problems caused by this defect, especially in industrial environments. In this paper, a method for performing the condition monitoring of electrode alignment degradation was developed following previous research, which has shown the relationship between the misalignment of short-circuited electrodes and the magnetic field generated by them. This method was carried out by means of a device capable of measuring the magnetic field. Finally, an integral system for the detection of misalignments in real production lines is presented. This system set behavior thresholds based on the experimentation, allowing the condition monitoring of the alignment after each welding cycle. MDPI 2022-11-01 /pmc/articles/PMC9657074/ /pubmed/36366111 http://dx.doi.org/10.3390/s22218412 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ibáñez, Daniel
García, Eduardo
Soret, Jesús
Martos, Julio
Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes
title Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes
title_full Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes
title_fullStr Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes
title_full_unstemmed Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes
title_short Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes
title_sort real-time condition monitoring system for electrode alignment in resistance welding electrodes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9657074/
https://www.ncbi.nlm.nih.gov/pubmed/36366111
http://dx.doi.org/10.3390/s22218412
work_keys_str_mv AT ibanezdaniel realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes
AT garciaeduardo realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes
AT soretjesus realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes
AT martosjulio realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes