Cargando…
Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes
Electrode misalignment, produced by mechanical fatigue or bad adjustments of the welding gun, leads to an increase in expulsions, deformations and quality problems of the welding joints. Different studies have focused on evaluations of the influence of a misalignment of the electrodes and the final...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9657074/ https://www.ncbi.nlm.nih.gov/pubmed/36366111 http://dx.doi.org/10.3390/s22218412 |
_version_ | 1784829600151371776 |
---|---|
author | Ibáñez, Daniel García, Eduardo Soret, Jesús Martos, Julio |
author_facet | Ibáñez, Daniel García, Eduardo Soret, Jesús Martos, Julio |
author_sort | Ibáñez, Daniel |
collection | PubMed |
description | Electrode misalignment, produced by mechanical fatigue or bad adjustments of the welding gun, leads to an increase in expulsions, deformations and quality problems of the welding joints. Different studies have focused on evaluations of the influence of a misalignment of the electrodes and the final quality of the weld nugget. However, few studies have focused on determining a misalignment of the electrodes to avoid problems caused by this defect, especially in industrial environments. In this paper, a method for performing the condition monitoring of electrode alignment degradation was developed following previous research, which has shown the relationship between the misalignment of short-circuited electrodes and the magnetic field generated by them. This method was carried out by means of a device capable of measuring the magnetic field. Finally, an integral system for the detection of misalignments in real production lines is presented. This system set behavior thresholds based on the experimentation, allowing the condition monitoring of the alignment after each welding cycle. |
format | Online Article Text |
id | pubmed-9657074 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96570742022-11-15 Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes Ibáñez, Daniel García, Eduardo Soret, Jesús Martos, Julio Sensors (Basel) Article Electrode misalignment, produced by mechanical fatigue or bad adjustments of the welding gun, leads to an increase in expulsions, deformations and quality problems of the welding joints. Different studies have focused on evaluations of the influence of a misalignment of the electrodes and the final quality of the weld nugget. However, few studies have focused on determining a misalignment of the electrodes to avoid problems caused by this defect, especially in industrial environments. In this paper, a method for performing the condition monitoring of electrode alignment degradation was developed following previous research, which has shown the relationship between the misalignment of short-circuited electrodes and the magnetic field generated by them. This method was carried out by means of a device capable of measuring the magnetic field. Finally, an integral system for the detection of misalignments in real production lines is presented. This system set behavior thresholds based on the experimentation, allowing the condition monitoring of the alignment after each welding cycle. MDPI 2022-11-01 /pmc/articles/PMC9657074/ /pubmed/36366111 http://dx.doi.org/10.3390/s22218412 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ibáñez, Daniel García, Eduardo Soret, Jesús Martos, Julio Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes |
title | Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes |
title_full | Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes |
title_fullStr | Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes |
title_full_unstemmed | Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes |
title_short | Real-Time Condition Monitoring System for Electrode Alignment in Resistance Welding Electrodes |
title_sort | real-time condition monitoring system for electrode alignment in resistance welding electrodes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9657074/ https://www.ncbi.nlm.nih.gov/pubmed/36366111 http://dx.doi.org/10.3390/s22218412 |
work_keys_str_mv | AT ibanezdaniel realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes AT garciaeduardo realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes AT soretjesus realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes AT martosjulio realtimeconditionmonitoringsystemforelectrodealignmentinresistanceweldingelectrodes |