Cargando…

Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode

Sensitive detection of prostate-specific antigens (PSA) in serum is essential for the prevention and early treatment of prostate cancer. Simple and disposable electrochemical immunosensors are highly desirable for screening and mobile detection of PSAs in high-risk populations. Here, an electrochemi...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Liang, Xu, Shuai, Xi, Fengna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9658386/
https://www.ncbi.nlm.nih.gov/pubmed/36364585
http://dx.doi.org/10.3390/nano12213810
_version_ 1784829938156699648
author Yan, Liang
Xu, Shuai
Xi, Fengna
author_facet Yan, Liang
Xu, Shuai
Xi, Fengna
author_sort Yan, Liang
collection PubMed
description Sensitive detection of prostate-specific antigens (PSA) in serum is essential for the prevention and early treatment of prostate cancer. Simple and disposable electrochemical immunosensors are highly desirable for screening and mobile detection of PSAs in high-risk populations. Here, an electrochemical immunosensor was constructed based on amino-rich nanochannels array-modified patterned, inexpensive, and disposable indium tin oxide (ITO) electrodes, which can be employed for the sensitive detection of PSA. Using an amino-group-containing precursor, a vertically ordered mesoporous silica nanochannel film (VMSF) containing amino groups (NH(2)-VMSF) was rapidly grown on ITO. When NH(2)-VMSF contained template surfactant micelle (SM), the outer surface of NH(2)-VMSF was directionally modified by aldehyde groups, which enabled further covalent immobilization of the recognitive antibody to prepare the immuno-recognitive interface. Owing to the charge-based selective permeability, NH(2)-VMSF can electrostatically adsorb negatively charged redox probes in solution (Fe(CN)(6)(3−/4−)). The electrochemical detection of PSA is realized based on the mechanism that the antigen–antibody complex can reduce the diffusion of redox probes in solution to the underlying electrode, leading to the decrease in electrochemical signal. The constructed immunosensor can achieve sensitive detection of PSA in the range from 10 pg/mL to 1 μg/mL with a limit of detection (LOD) of 8.1 pg/mL. Sensitive detection of PSA in human serum was also achieved. The proposed disposable immunosensor based on cheap electrode and nanochannel array is expected to provide a new idea for developing a universal immunosensing platform for sensitive detection of tumor markers.
format Online
Article
Text
id pubmed-9658386
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96583862022-11-15 Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode Yan, Liang Xu, Shuai Xi, Fengna Nanomaterials (Basel) Article Sensitive detection of prostate-specific antigens (PSA) in serum is essential for the prevention and early treatment of prostate cancer. Simple and disposable electrochemical immunosensors are highly desirable for screening and mobile detection of PSAs in high-risk populations. Here, an electrochemical immunosensor was constructed based on amino-rich nanochannels array-modified patterned, inexpensive, and disposable indium tin oxide (ITO) electrodes, which can be employed for the sensitive detection of PSA. Using an amino-group-containing precursor, a vertically ordered mesoporous silica nanochannel film (VMSF) containing amino groups (NH(2)-VMSF) was rapidly grown on ITO. When NH(2)-VMSF contained template surfactant micelle (SM), the outer surface of NH(2)-VMSF was directionally modified by aldehyde groups, which enabled further covalent immobilization of the recognitive antibody to prepare the immuno-recognitive interface. Owing to the charge-based selective permeability, NH(2)-VMSF can electrostatically adsorb negatively charged redox probes in solution (Fe(CN)(6)(3−/4−)). The electrochemical detection of PSA is realized based on the mechanism that the antigen–antibody complex can reduce the diffusion of redox probes in solution to the underlying electrode, leading to the decrease in electrochemical signal. The constructed immunosensor can achieve sensitive detection of PSA in the range from 10 pg/mL to 1 μg/mL with a limit of detection (LOD) of 8.1 pg/mL. Sensitive detection of PSA in human serum was also achieved. The proposed disposable immunosensor based on cheap electrode and nanochannel array is expected to provide a new idea for developing a universal immunosensing platform for sensitive detection of tumor markers. MDPI 2022-10-28 /pmc/articles/PMC9658386/ /pubmed/36364585 http://dx.doi.org/10.3390/nano12213810 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yan, Liang
Xu, Shuai
Xi, Fengna
Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode
title Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode
title_full Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode
title_fullStr Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode
title_full_unstemmed Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode
title_short Disposal Immunosensor for Sensitive Electrochemical Detection of Prostate-Specific Antigen Based on Amino-Rich Nanochannels Array-Modified Patterned Indium Tin Oxide Electrode
title_sort disposal immunosensor for sensitive electrochemical detection of prostate-specific antigen based on amino-rich nanochannels array-modified patterned indium tin oxide electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9658386/
https://www.ncbi.nlm.nih.gov/pubmed/36364585
http://dx.doi.org/10.3390/nano12213810
work_keys_str_mv AT yanliang disposalimmunosensorforsensitiveelectrochemicaldetectionofprostatespecificantigenbasedonaminorichnanochannelsarraymodifiedpatternedindiumtinoxideelectrode
AT xushuai disposalimmunosensorforsensitiveelectrochemicaldetectionofprostatespecificantigenbasedonaminorichnanochannelsarraymodifiedpatternedindiumtinoxideelectrode
AT xifengna disposalimmunosensorforsensitiveelectrochemicaldetectionofprostatespecificantigenbasedonaminorichnanochannelsarraymodifiedpatternedindiumtinoxideelectrode