Cargando…
High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions
Realizing coherent sampling is one of the major bottlenecks in high-precision ADC spectrum testing. In spectrum analysis, if coherent sampling is not implemented, spectral leakage will result, which in turn leads to inaccurate test results. In this paper, a combined four-parameter sine-curve-fitting...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9658732/ https://www.ncbi.nlm.nih.gov/pubmed/36365865 http://dx.doi.org/10.3390/s22218170 |
_version_ | 1784830024069677056 |
---|---|
author | Peng, Xiaofei Li, Jie Zhang, Debiao Hu, Chenjun Sun, Ning Jiang, Jie |
author_facet | Peng, Xiaofei Li, Jie Zhang, Debiao Hu, Chenjun Sun, Ning Jiang, Jie |
author_sort | Peng, Xiaofei |
collection | PubMed |
description | Realizing coherent sampling is one of the major bottlenecks in high-precision ADC spectrum testing. In spectrum analysis, if coherent sampling is not implemented, spectral leakage will result, which in turn leads to inaccurate test results. In this paper, a combined four-parameter sine-curve-fitting algorithm is proposed incorporating non-coherent sampling, with the amplitude, initial phase, and frequency parameters of the sine wave being obtained by fitting. The corresponding coherent sine wave is then calculated and replaced according to the obtained sine wave to reconstruct the new test data, eliminating the requirement of coherent sampling. Numerous simulations demonstrated the functionality and robustness of the algorithm, which was then used to process and analyze the measured data of two commercial high-precision ADCs. The results show that our algorithm can achieve accurate testing of ADC parameters under relaxed test conditions, which verifies the effectiveness and superiority of the scheme. |
format | Online Article Text |
id | pubmed-9658732 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96587322022-11-15 High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions Peng, Xiaofei Li, Jie Zhang, Debiao Hu, Chenjun Sun, Ning Jiang, Jie Sensors (Basel) Article Realizing coherent sampling is one of the major bottlenecks in high-precision ADC spectrum testing. In spectrum analysis, if coherent sampling is not implemented, spectral leakage will result, which in turn leads to inaccurate test results. In this paper, a combined four-parameter sine-curve-fitting algorithm is proposed incorporating non-coherent sampling, with the amplitude, initial phase, and frequency parameters of the sine wave being obtained by fitting. The corresponding coherent sine wave is then calculated and replaced according to the obtained sine wave to reconstruct the new test data, eliminating the requirement of coherent sampling. Numerous simulations demonstrated the functionality and robustness of the algorithm, which was then used to process and analyze the measured data of two commercial high-precision ADCs. The results show that our algorithm can achieve accurate testing of ADC parameters under relaxed test conditions, which verifies the effectiveness and superiority of the scheme. MDPI 2022-10-25 /pmc/articles/PMC9658732/ /pubmed/36365865 http://dx.doi.org/10.3390/s22218170 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Peng, Xiaofei Li, Jie Zhang, Debiao Hu, Chenjun Sun, Ning Jiang, Jie High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions |
title | High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions |
title_full | High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions |
title_fullStr | High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions |
title_full_unstemmed | High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions |
title_short | High-Precision ADC Spectrum Testing under Non-Coherent Sampling Conditions |
title_sort | high-precision adc spectrum testing under non-coherent sampling conditions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9658732/ https://www.ncbi.nlm.nih.gov/pubmed/36365865 http://dx.doi.org/10.3390/s22218170 |
work_keys_str_mv | AT pengxiaofei highprecisionadcspectrumtestingundernoncoherentsamplingconditions AT lijie highprecisionadcspectrumtestingundernoncoherentsamplingconditions AT zhangdebiao highprecisionadcspectrumtestingundernoncoherentsamplingconditions AT huchenjun highprecisionadcspectrumtestingundernoncoherentsamplingconditions AT sunning highprecisionadcspectrumtestingundernoncoherentsamplingconditions AT jiangjie highprecisionadcspectrumtestingundernoncoherentsamplingconditions |