Cargando…

Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography

Bisphenols (BPs) are a class of endocrine disruptors widely existing in the environment. They have a great impact on human health owing to their environmental endocrine disrupting effects, chronic toxicity, neurotoxicity, cytotoxicity and genetic toxicity. In this paper, an on-line packed fiber soli...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Tong, Zhang, Rui, Bi, Yueling, Li, Jingjing, Li, Xiaohuan, Chen, Liqin, Fang, Zhongze
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659129/
https://www.ncbi.nlm.nih.gov/pubmed/36365764
http://dx.doi.org/10.3390/polym14214765
_version_ 1784830125212172288
author Xu, Tong
Zhang, Rui
Bi, Yueling
Li, Jingjing
Li, Xiaohuan
Chen, Liqin
Fang, Zhongze
author_facet Xu, Tong
Zhang, Rui
Bi, Yueling
Li, Jingjing
Li, Xiaohuan
Chen, Liqin
Fang, Zhongze
author_sort Xu, Tong
collection PubMed
description Bisphenols (BPs) are a class of endocrine disruptors widely existing in the environment. They have a great impact on human health owing to their environmental endocrine disrupting effects, chronic toxicity, neurotoxicity, cytotoxicity and genetic toxicity. In this paper, an on-line packed fiber solid phase extraction (PFSPE) coupling with column-switching HPLC-FLD determination method was developed for the determination of eight BPs in drinking water. The poly (dibenzo-18-crown-6-ether)/polystyrene composite nanofibers (PDB18C6/PS) were prepared by electrospinning and used as an adsorbent for the on-line PFSPE column. The on-line PFSPE-HPLC equipment contained a dual ternary pump and a switching valve to enable enrichment, purification, and analysis directly in the system. The results showed that the proposed on-line PFSPE-HPLC-FLD method realized the simultaneous separation and detection of eight BPs: BPF, BPE, BPA, BPB, BPAF, BPAP, BPC and BPZ. The curves of the target analytes were prepared with good correlation coefficient values (r(2) > 0.998) in the range of 50–1000 pg/mL. The limit of detection (S/N = 3) was 20 pg/mL, the limit of quantitation (S/N = 10) is 50 pg/mL. The recoveries of eight BPs were 94.8–127.3%, and the intra-day precisions (RSD) were less than 10%. The PFSPE column made of the PDB18C6/PS composite nanofibers has stable properties and can be reused at least 200 times. In the detection of drinking water samples, BPZ was detected in nearly 80% of drinking water samples, and BPA, BPAP, BPF and BPAF were also detected in some water samples. This high level of integration and automation was achieved in pretreatment of eight BPs from water samples. The proposed simple, rapid, and practical method has been successfully applied to the detection of eight BPs in drinking water, which can provide powerful technical support for drinking water quality and safety monitoring.
format Online
Article
Text
id pubmed-9659129
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96591292022-11-15 Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography Xu, Tong Zhang, Rui Bi, Yueling Li, Jingjing Li, Xiaohuan Chen, Liqin Fang, Zhongze Polymers (Basel) Article Bisphenols (BPs) are a class of endocrine disruptors widely existing in the environment. They have a great impact on human health owing to their environmental endocrine disrupting effects, chronic toxicity, neurotoxicity, cytotoxicity and genetic toxicity. In this paper, an on-line packed fiber solid phase extraction (PFSPE) coupling with column-switching HPLC-FLD determination method was developed for the determination of eight BPs in drinking water. The poly (dibenzo-18-crown-6-ether)/polystyrene composite nanofibers (PDB18C6/PS) were prepared by electrospinning and used as an adsorbent for the on-line PFSPE column. The on-line PFSPE-HPLC equipment contained a dual ternary pump and a switching valve to enable enrichment, purification, and analysis directly in the system. The results showed that the proposed on-line PFSPE-HPLC-FLD method realized the simultaneous separation and detection of eight BPs: BPF, BPE, BPA, BPB, BPAF, BPAP, BPC and BPZ. The curves of the target analytes were prepared with good correlation coefficient values (r(2) > 0.998) in the range of 50–1000 pg/mL. The limit of detection (S/N = 3) was 20 pg/mL, the limit of quantitation (S/N = 10) is 50 pg/mL. The recoveries of eight BPs were 94.8–127.3%, and the intra-day precisions (RSD) were less than 10%. The PFSPE column made of the PDB18C6/PS composite nanofibers has stable properties and can be reused at least 200 times. In the detection of drinking water samples, BPZ was detected in nearly 80% of drinking water samples, and BPA, BPAP, BPF and BPAF were also detected in some water samples. This high level of integration and automation was achieved in pretreatment of eight BPs from water samples. The proposed simple, rapid, and practical method has been successfully applied to the detection of eight BPs in drinking water, which can provide powerful technical support for drinking water quality and safety monitoring. MDPI 2022-11-07 /pmc/articles/PMC9659129/ /pubmed/36365764 http://dx.doi.org/10.3390/polym14214765 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xu, Tong
Zhang, Rui
Bi, Yueling
Li, Jingjing
Li, Xiaohuan
Chen, Liqin
Fang, Zhongze
Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography
title Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography
title_full Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography
title_fullStr Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography
title_full_unstemmed Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography
title_short Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography
title_sort electrospun polycrown ether composite nanofibers as an adsorbent for on-line solid phase extraction of eight bisphenols from drinking water samples with column-switching prior to high performance liquid chromatography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659129/
https://www.ncbi.nlm.nih.gov/pubmed/36365764
http://dx.doi.org/10.3390/polym14214765
work_keys_str_mv AT xutong electrospunpolycrownethercompositenanofibersasanadsorbentforonlinesolidphaseextractionofeightbisphenolsfromdrinkingwatersampleswithcolumnswitchingpriortohighperformanceliquidchromatography
AT zhangrui electrospunpolycrownethercompositenanofibersasanadsorbentforonlinesolidphaseextractionofeightbisphenolsfromdrinkingwatersampleswithcolumnswitchingpriortohighperformanceliquidchromatography
AT biyueling electrospunpolycrownethercompositenanofibersasanadsorbentforonlinesolidphaseextractionofeightbisphenolsfromdrinkingwatersampleswithcolumnswitchingpriortohighperformanceliquidchromatography
AT lijingjing electrospunpolycrownethercompositenanofibersasanadsorbentforonlinesolidphaseextractionofeightbisphenolsfromdrinkingwatersampleswithcolumnswitchingpriortohighperformanceliquidchromatography
AT lixiaohuan electrospunpolycrownethercompositenanofibersasanadsorbentforonlinesolidphaseextractionofeightbisphenolsfromdrinkingwatersampleswithcolumnswitchingpriortohighperformanceliquidchromatography
AT chenliqin electrospunpolycrownethercompositenanofibersasanadsorbentforonlinesolidphaseextractionofeightbisphenolsfromdrinkingwatersampleswithcolumnswitchingpriortohighperformanceliquidchromatography
AT fangzhongze electrospunpolycrownethercompositenanofibersasanadsorbentforonlinesolidphaseextractionofeightbisphenolsfromdrinkingwatersampleswithcolumnswitchingpriortohighperformanceliquidchromatography