Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature
This article presents diagnostic tests of wire ropes using passive magnetic methods. The study used two types of wire ropes with different constructions and diameters. Defects of various depths were modeled in the ropes, which reflected the degree of loss of metallic cross-section. After a series of...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659159/ https://www.ncbi.nlm.nih.gov/pubmed/36365863 http://dx.doi.org/10.3390/s22218162 |
_version_ | 1784830132485095424 |
---|---|
author | Mazurek, Paweł Roskosz, Maciej Kwaśniewski, Jerzy |
author_facet | Mazurek, Paweł Roskosz, Maciej Kwaśniewski, Jerzy |
author_sort | Mazurek, Paweł |
collection | PubMed |
description | This article presents diagnostic tests of wire ropes using passive magnetic methods. The study used two types of wire ropes with different constructions and diameters. Defects of various depths were modeled in the ropes, which reflected the degree of loss of metallic cross-section. After a series of measurements, a correlation was observed between the amplitude of the module signal and the degree of damage to the rope. The signals were recorded with the advantage of the SpinMeter-3D magnetometer. The obtained results were subjected to the extraction of features, the analysis of which allowed the damage to be identified. |
format | Online Article Text |
id | pubmed-9659159 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96591592022-11-15 Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature Mazurek, Paweł Roskosz, Maciej Kwaśniewski, Jerzy Sensors (Basel) Article This article presents diagnostic tests of wire ropes using passive magnetic methods. The study used two types of wire ropes with different constructions and diameters. Defects of various depths were modeled in the ropes, which reflected the degree of loss of metallic cross-section. After a series of measurements, a correlation was observed between the amplitude of the module signal and the degree of damage to the rope. The signals were recorded with the advantage of the SpinMeter-3D magnetometer. The obtained results were subjected to the extraction of features, the analysis of which allowed the damage to be identified. MDPI 2022-10-25 /pmc/articles/PMC9659159/ /pubmed/36365863 http://dx.doi.org/10.3390/s22218162 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mazurek, Paweł Roskosz, Maciej Kwaśniewski, Jerzy Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature |
title | Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature |
title_full | Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature |
title_fullStr | Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature |
title_full_unstemmed | Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature |
title_short | Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature |
title_sort | influence of the size of damage to the steel wire rope on the magnetic signature |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659159/ https://www.ncbi.nlm.nih.gov/pubmed/36365863 http://dx.doi.org/10.3390/s22218162 |
work_keys_str_mv | AT mazurekpaweł influenceofthesizeofdamagetothesteelwireropeonthemagneticsignature AT roskoszmaciej influenceofthesizeofdamagetothesteelwireropeonthemagneticsignature AT kwasniewskijerzy influenceofthesizeofdamagetothesteelwireropeonthemagneticsignature |