Cargando…

The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus

CATEGORY: Midfoot/Forefoot INTRODUCTION/PURPOSE: Weight-Bearing Computed Tomography (WBCT) measurements represent a reliable tool for radiographic analysis of the first ray, including multiplanar assessment in the axial, sagittal, and coronal planes. WBCT can allow for more reliable studies of patho...

Descripción completa

Detalles Bibliográficos
Autores principales: Carvalho, Kepler, Mallavarapu, Vinnel, Jasper, Ryan, Lee, Hee Young, Mansur, Nacime SB, Dibbern, Kevin N., Den Hartog, Taylor, Behrens, Andrew, Kim, Ki Chun, Godoy-Santos, Alexandre L., Netto, Cesar de Cesar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659777/
http://dx.doi.org/10.1177/2473011421S00611
_version_ 1784830273034125312
author Carvalho, Kepler
Mallavarapu, Vinnel
Jasper, Ryan
Lee, Hee Young
Mansur, Nacime SB
Dibbern, Kevin N.
Den Hartog, Taylor
Behrens, Andrew
Kim, Ki Chun
Godoy-Santos, Alexandre L.
Netto, Cesar de Cesar
author_facet Carvalho, Kepler
Mallavarapu, Vinnel
Jasper, Ryan
Lee, Hee Young
Mansur, Nacime SB
Dibbern, Kevin N.
Den Hartog, Taylor
Behrens, Andrew
Kim, Ki Chun
Godoy-Santos, Alexandre L.
Netto, Cesar de Cesar
author_sort Carvalho, Kepler
collection PubMed
description CATEGORY: Midfoot/Forefoot INTRODUCTION/PURPOSE: Weight-Bearing Computed Tomography (WBCT) measurements represent a reliable tool for radiographic analysis of the first ray, including multiplanar assessment in the axial, sagittal, and coronal planes. WBCT can allow for more reliable studies of pathologies, such as Hallux Rigidus (HR), which permits several anatomical points to be evaluated for a correct clinical-radiographic diagnosis. In addition, new software with an advanced semi-automated segmentation system obtains semi-automatic 3D measurements of WBCT scan data sets, minimizing the errors in reading angular measurements. The study`s objective was (1) to assess the reliability of WBCT computer-assisted semi-automatic imaging measurements in HR, (2) to compare semi-automatic to manual measurements in the setting of HR, and (3) to compare semi-automatic measurements between a pathologic (HR) group and a control standard group. METHODS: This was a retrospective, IRB approved study of patients with Hallux Rigidus deformity. The sample size calculation was based on the Metatarsus Primus Elevatus (MPE). A control group consisting of 20 feet without HR and a pathologic group consisting of 20 feet with HR was necessary for this study. All WBCT manual and semiautomatic 3D measurements were performed using the following parameters: (1) first Metatarsal-Proximal Phalanx Angle (1stMPP) (sagittal plane), (2) Hallux Valgus Angle (HVA), (3) first to second Intermetatarsal Angle (IMA), (4) Hallux Interphalangeal Angle (IPA), (5) first Metatarsal Lengths (1stML), (6) second Metatarsal Length (2ndML), (7) first Metatarsal Declination Angle (1stMD), (8) second Metatarsal Declination Angles (2ndMD), and (9) MPE. The semiautomatic 3D measurements were performed using the Bonelogic Software. The differences between pathologic and control cases were assessed with a Wilcoxon test and P<= 0.05 was considered significant. RESULTS: Interobserver and intraobserver agreement and consistency for manual versus semi-automatic WBCT measurements assessed by ICC demonstrated excellent reliability. Manual and semi-automatic measurements were performed in individuals with HR. According to the Pearson's coefficient, there was a strong positive linear correlation between both methods for the following parameters evaluated: HVA, (ρ = 0.96); IMA, (ρ = 0.86); IPA, (ρ = 0.89); 1stML, (ρ = 0.96); 2ndML, (ρ = 0.91); 1stMD, (ρ = 0.86); 2ndMD, (ρ = 0.95) and, MPE, (ρ = 0.87). Agreement between the manual and semi-automatic methods was tested using a Bland- Altman plot and expressed excellent agreement between the methods. Comparison between the pathological group with HR and the control (standard) group allowed for the differentiating of the pathological (HR) from the non-pathological conditions for MPE (p < 0.05). CONCLUSION: Semiautomatic measurements are reproducible and comparable to measurements performed manually, showing excellent interobserver and intraobserver agreement and consistency. The software used differentiated pathological from non- pathological conditions only when submitted to semi-automatic MPE measurements. The development of advanced semi-automatic segmentation software with minimal user intervention is an essential step toward the establishment of big data and can be integrated into clinical practice, facilitating decision making.
format Online
Article
Text
id pubmed-9659777
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-96597772022-11-15 The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus Carvalho, Kepler Mallavarapu, Vinnel Jasper, Ryan Lee, Hee Young Mansur, Nacime SB Dibbern, Kevin N. Den Hartog, Taylor Behrens, Andrew Kim, Ki Chun Godoy-Santos, Alexandre L. Netto, Cesar de Cesar Foot Ankle Orthop Article CATEGORY: Midfoot/Forefoot INTRODUCTION/PURPOSE: Weight-Bearing Computed Tomography (WBCT) measurements represent a reliable tool for radiographic analysis of the first ray, including multiplanar assessment in the axial, sagittal, and coronal planes. WBCT can allow for more reliable studies of pathologies, such as Hallux Rigidus (HR), which permits several anatomical points to be evaluated for a correct clinical-radiographic diagnosis. In addition, new software with an advanced semi-automated segmentation system obtains semi-automatic 3D measurements of WBCT scan data sets, minimizing the errors in reading angular measurements. The study`s objective was (1) to assess the reliability of WBCT computer-assisted semi-automatic imaging measurements in HR, (2) to compare semi-automatic to manual measurements in the setting of HR, and (3) to compare semi-automatic measurements between a pathologic (HR) group and a control standard group. METHODS: This was a retrospective, IRB approved study of patients with Hallux Rigidus deformity. The sample size calculation was based on the Metatarsus Primus Elevatus (MPE). A control group consisting of 20 feet without HR and a pathologic group consisting of 20 feet with HR was necessary for this study. All WBCT manual and semiautomatic 3D measurements were performed using the following parameters: (1) first Metatarsal-Proximal Phalanx Angle (1stMPP) (sagittal plane), (2) Hallux Valgus Angle (HVA), (3) first to second Intermetatarsal Angle (IMA), (4) Hallux Interphalangeal Angle (IPA), (5) first Metatarsal Lengths (1stML), (6) second Metatarsal Length (2ndML), (7) first Metatarsal Declination Angle (1stMD), (8) second Metatarsal Declination Angles (2ndMD), and (9) MPE. The semiautomatic 3D measurements were performed using the Bonelogic Software. The differences between pathologic and control cases were assessed with a Wilcoxon test and P<= 0.05 was considered significant. RESULTS: Interobserver and intraobserver agreement and consistency for manual versus semi-automatic WBCT measurements assessed by ICC demonstrated excellent reliability. Manual and semi-automatic measurements were performed in individuals with HR. According to the Pearson's coefficient, there was a strong positive linear correlation between both methods for the following parameters evaluated: HVA, (ρ = 0.96); IMA, (ρ = 0.86); IPA, (ρ = 0.89); 1stML, (ρ = 0.96); 2ndML, (ρ = 0.91); 1stMD, (ρ = 0.86); 2ndMD, (ρ = 0.95) and, MPE, (ρ = 0.87). Agreement between the manual and semi-automatic methods was tested using a Bland- Altman plot and expressed excellent agreement between the methods. Comparison between the pathological group with HR and the control (standard) group allowed for the differentiating of the pathological (HR) from the non-pathological conditions for MPE (p < 0.05). CONCLUSION: Semiautomatic measurements are reproducible and comparable to measurements performed manually, showing excellent interobserver and intraobserver agreement and consistency. The software used differentiated pathological from non- pathological conditions only when submitted to semi-automatic MPE measurements. The development of advanced semi-automatic segmentation software with minimal user intervention is an essential step toward the establishment of big data and can be integrated into clinical practice, facilitating decision making. SAGE Publications 2022-11-10 /pmc/articles/PMC9659777/ http://dx.doi.org/10.1177/2473011421S00611 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Carvalho, Kepler
Mallavarapu, Vinnel
Jasper, Ryan
Lee, Hee Young
Mansur, Nacime SB
Dibbern, Kevin N.
Den Hartog, Taylor
Behrens, Andrew
Kim, Ki Chun
Godoy-Santos, Alexandre L.
Netto, Cesar de Cesar
The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus
title The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus
title_full The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus
title_fullStr The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus
title_full_unstemmed The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus
title_short The Use of Advanced Semi-Automated Bone Segmentation in Hallux Rigidus
title_sort use of advanced semi-automated bone segmentation in hallux rigidus
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659777/
http://dx.doi.org/10.1177/2473011421S00611
work_keys_str_mv AT carvalhokepler theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT mallavarapuvinnel theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT jasperryan theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT leeheeyoung theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT mansurnacimesb theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT dibbernkevinn theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT denhartogtaylor theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT behrensandrew theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT kimkichun theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT godoysantosalexandrel theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT nettocesardecesar theuseofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT carvalhokepler useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT mallavarapuvinnel useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT jasperryan useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT leeheeyoung useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT mansurnacimesb useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT dibbernkevinn useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT denhartogtaylor useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT behrensandrew useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT kimkichun useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT godoysantosalexandrel useofadvancedsemiautomatedbonesegmentationinhalluxrigidus
AT nettocesardecesar useofadvancedsemiautomatedbonesegmentationinhalluxrigidus