Cargando…

Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments

CATEGORY: Hindfoot; Basic Sciences/Biologics; Other INTRODUCTION/PURPOSE: Progressive collapsing foot deformity (PCFD) is a complex three-dimensional (3D) deformity where adjacent structures may adopt subtle differences in positioning that result in increased contact or subluxation. Recent studies h...

Descripción completa

Detalles Bibliográficos
Autores principales: Dibbern, Kevin N., Behrens, Andrew, Mansur, Nacime SB, Carvalho, Kepler, Lalevée, Matthieu, Kim, Ki Chun, Schmidt, Eli, de Cesar Netto, Cesar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659787/
http://dx.doi.org/10.1177/2473011421S00651
_version_ 1784830275633545216
author Dibbern, Kevin N.
Behrens, Andrew
Mansur, Nacime SB
Carvalho, Kepler
Lalevée, Matthieu
Kim, Ki Chun
Schmidt, Eli
de Cesar Netto, Cesar
author_facet Dibbern, Kevin N.
Behrens, Andrew
Mansur, Nacime SB
Carvalho, Kepler
Lalevée, Matthieu
Kim, Ki Chun
Schmidt, Eli
de Cesar Netto, Cesar
author_sort Dibbern, Kevin N.
collection PubMed
description CATEGORY: Hindfoot; Basic Sciences/Biologics; Other INTRODUCTION/PURPOSE: Progressive collapsing foot deformity (PCFD) is a complex three-dimensional (3D) deformity where adjacent structures may adopt subtle differences in positioning that result in increased contact or subluxation. Recent studies have highlighted the need for and utility of 3D analyses in PCFD using weightbearing CT (WBCT) and bone segmentation. Beyond the limitations of triplanar imaging, 3D distance and coverage mapping analyses have further highlighted key regional differences like sinus tarsi narrowing ahead of impingement and early middle facet uncoverage ahead of collapse. However, these analyses rely upon manual identification of subregions hindering the utility of 3D mapping clinically. The objective of this study was to compare an automated selection process with manual selections in the context of subtalar regional distance and coverage maps in PCFD. METHODS: In this IRB-approved retrospective study, WBCT data of 20 consecutive patients with flexible PCFD and 10 controls were analyzed. Subregions of the peritalar surface (middle and posterior facets of the calcaneus and talus; sinus tarsi area) were manually selected by two experts on manually generated bone surfaces of all 30 feet. An automated algorithm for selecting coverage area was applied to identify the same regions on the semi-automatically generated bones (Figure). A 3D distance mapping (DM) technique was used to create coverage maps (CMs) across the entire peritalar surface where areas with distances less than 4mm were defined as covered. DM and CM percentages were compared using intra-class correlations and t-tests between PCFD and control groups. The Sørensen–Dice index, or Dice coefficient, was used for comparisons of selections on the semi-automated surfaces to evaluate reproducibility of expert selections. RESULTS: The automated process produced identical selections resulting in perfect intra-method ICCs of 1.00 for all regions and Dice coefficients of 1.00. The average Dice coefficient for all manual selections was 0.903 (range: 0.865-0.935) indicating that observers were able to reliably select the same regions with 90% overlap. When assessing reliability of manual selections, intra- observer ICCs ranged from 0.41-0.92 while inter-observer ICCs ranged from 0.47-0.99 were found. Despite strong significant correlations, average coverage was significantly lower in the sinus tarsi region of the automated selections vs the manual selections (34.3+-16.8% vs 23.1+-12.7%, p<0.005). However, mean distances in each region were not significantly different in the middle facet or the sinus tarsi regions (p=0.323, p=0.095, respectively). CONCLUSION: Understanding of the complex 3D deformities that constitute PCFD requires sensitive and reproducible measures. Fully automated 3D assessments of coverage and bone relations may have the potential to improve understanding of these deformities aiding in diagnosis, staging, and objective evaluation of treatment effects. Prior work with 3D coverage and distance maps specifically identified the middle facet and sinus tarsi regions as being of particular importance. Compared to manual selections, these regions were well identified by the automated process. This represents a step toward the goal of viable use of fully automated 3D coverage and distance mapping when evaluating PCFD patients.
format Online
Article
Text
id pubmed-9659787
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-96597872022-11-15 Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments Dibbern, Kevin N. Behrens, Andrew Mansur, Nacime SB Carvalho, Kepler Lalevée, Matthieu Kim, Ki Chun Schmidt, Eli de Cesar Netto, Cesar Foot Ankle Orthop Article CATEGORY: Hindfoot; Basic Sciences/Biologics; Other INTRODUCTION/PURPOSE: Progressive collapsing foot deformity (PCFD) is a complex three-dimensional (3D) deformity where adjacent structures may adopt subtle differences in positioning that result in increased contact or subluxation. Recent studies have highlighted the need for and utility of 3D analyses in PCFD using weightbearing CT (WBCT) and bone segmentation. Beyond the limitations of triplanar imaging, 3D distance and coverage mapping analyses have further highlighted key regional differences like sinus tarsi narrowing ahead of impingement and early middle facet uncoverage ahead of collapse. However, these analyses rely upon manual identification of subregions hindering the utility of 3D mapping clinically. The objective of this study was to compare an automated selection process with manual selections in the context of subtalar regional distance and coverage maps in PCFD. METHODS: In this IRB-approved retrospective study, WBCT data of 20 consecutive patients with flexible PCFD and 10 controls were analyzed. Subregions of the peritalar surface (middle and posterior facets of the calcaneus and talus; sinus tarsi area) were manually selected by two experts on manually generated bone surfaces of all 30 feet. An automated algorithm for selecting coverage area was applied to identify the same regions on the semi-automatically generated bones (Figure). A 3D distance mapping (DM) technique was used to create coverage maps (CMs) across the entire peritalar surface where areas with distances less than 4mm were defined as covered. DM and CM percentages were compared using intra-class correlations and t-tests between PCFD and control groups. The Sørensen–Dice index, or Dice coefficient, was used for comparisons of selections on the semi-automated surfaces to evaluate reproducibility of expert selections. RESULTS: The automated process produced identical selections resulting in perfect intra-method ICCs of 1.00 for all regions and Dice coefficients of 1.00. The average Dice coefficient for all manual selections was 0.903 (range: 0.865-0.935) indicating that observers were able to reliably select the same regions with 90% overlap. When assessing reliability of manual selections, intra- observer ICCs ranged from 0.41-0.92 while inter-observer ICCs ranged from 0.47-0.99 were found. Despite strong significant correlations, average coverage was significantly lower in the sinus tarsi region of the automated selections vs the manual selections (34.3+-16.8% vs 23.1+-12.7%, p<0.005). However, mean distances in each region were not significantly different in the middle facet or the sinus tarsi regions (p=0.323, p=0.095, respectively). CONCLUSION: Understanding of the complex 3D deformities that constitute PCFD requires sensitive and reproducible measures. Fully automated 3D assessments of coverage and bone relations may have the potential to improve understanding of these deformities aiding in diagnosis, staging, and objective evaluation of treatment effects. Prior work with 3D coverage and distance maps specifically identified the middle facet and sinus tarsi regions as being of particular importance. Compared to manual selections, these regions were well identified by the automated process. This represents a step toward the goal of viable use of fully automated 3D coverage and distance mapping when evaluating PCFD patients. SAGE Publications 2022-11-11 /pmc/articles/PMC9659787/ http://dx.doi.org/10.1177/2473011421S00651 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Dibbern, Kevin N.
Behrens, Andrew
Mansur, Nacime SB
Carvalho, Kepler
Lalevée, Matthieu
Kim, Ki Chun
Schmidt, Eli
de Cesar Netto, Cesar
Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments
title Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments
title_full Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments
title_fullStr Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments
title_full_unstemmed Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments
title_short Evaluation of Automated Coverage and Distance Mapping Selections to Improve Reliability and Clinical Utility of 3D Weightbearing CT Assessments
title_sort evaluation of automated coverage and distance mapping selections to improve reliability and clinical utility of 3d weightbearing ct assessments
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659787/
http://dx.doi.org/10.1177/2473011421S00651
work_keys_str_mv AT dibbernkevinn evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments
AT behrensandrew evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments
AT mansurnacimesb evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments
AT carvalhokepler evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments
AT laleveematthieu evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments
AT kimkichun evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments
AT schmidteli evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments
AT decesarnettocesar evaluationofautomatedcoverageanddistancemappingselectionstoimprovereliabilityandclinicalutilityof3dweightbearingctassessments