The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study

BACKGROUND AND AIMS: During laparoscopic surgeries, pneumoperitoneum increases intraabdominal pressure (IAP) which can increase the central venous pressure (CVP), and significant haemodynamic changes. In this study, we evaluated the effect of two different pressures of pneumoperitoneum, standard (13...

Descripción completa

Detalles Bibliográficos
Autores principales: Ponduru, Supraja, Nanda, Ananya, Pakhare, Vandana, Ramchandran, Gopinath, Sangineni, Kalyani S., Priyanka, R. Devi Sai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9662095/
https://www.ncbi.nlm.nih.gov/pubmed/36388446
http://dx.doi.org/10.4103/ija.ija_350_22
_version_ 1784830617867780096
author Ponduru, Supraja
Nanda, Ananya
Pakhare, Vandana
Ramchandran, Gopinath
Sangineni, Kalyani S.
Priyanka, R. Devi Sai
author_facet Ponduru, Supraja
Nanda, Ananya
Pakhare, Vandana
Ramchandran, Gopinath
Sangineni, Kalyani S.
Priyanka, R. Devi Sai
author_sort Ponduru, Supraja
collection PubMed
description BACKGROUND AND AIMS: During laparoscopic surgeries, pneumoperitoneum increases intraabdominal pressure (IAP) which can increase the central venous pressure (CVP), and significant haemodynamic changes. In this study, we evaluated the effect of two different pressures of pneumoperitoneum, standard (13-15 mmHg), and low (6-8 mmHg) on the cross-sectional area (CSA) of the internal jugular vein (IJV) using ultrasonography, haemodynamic changes and duration of surgery. Surgeon’s comfort and feasibility of performing laparoscopic surgeries with low pressure pneumoperitoneum was also studied. METHODS: This prospective, double-blind, randomised study included 148 patients of American Society of Anesthesiologists physical status class I and II undergoing laparoscopic surgeries. They were allocated into two groups: group S (standard) (number (n) = 73) had the IAP maintained between 13-15 mmHg; group L (low) had an IAP of 6-8 mmHg (n = 75). CSA of right IJV was measured before induction of anaesthesia (T1), 5 min after intubation (T2), 5 min after pneumoperitoneum (T3), before desufflation (T4) and 5 min prior to extubation (T5). Chi-square test, and Student’s paired and unpaired t test were used for statistical analysis. RESULTS: The increase in IJV CSA at T3 when compared to T2 was statistically significant in both the groups (P < 0.001). On desufflation, the change in IJV CSA showed significant decrease in T5 value than T4 value in both the groups (P < 0.001). However, the percentage change in the IJV CSA was more in group S (35.4%) than group L (21.2%). CONCLUSION: CSA of IJV increased significantly even with lower IAP of 6-8 mmHg. Laparoscopic surgery can be performed conveniently even at low IAP.
format Online
Article
Text
id pubmed-9662095
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-96620952022-11-15 The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study Ponduru, Supraja Nanda, Ananya Pakhare, Vandana Ramchandran, Gopinath Sangineni, Kalyani S. Priyanka, R. Devi Sai Indian J Anaesth Original Article BACKGROUND AND AIMS: During laparoscopic surgeries, pneumoperitoneum increases intraabdominal pressure (IAP) which can increase the central venous pressure (CVP), and significant haemodynamic changes. In this study, we evaluated the effect of two different pressures of pneumoperitoneum, standard (13-15 mmHg), and low (6-8 mmHg) on the cross-sectional area (CSA) of the internal jugular vein (IJV) using ultrasonography, haemodynamic changes and duration of surgery. Surgeon’s comfort and feasibility of performing laparoscopic surgeries with low pressure pneumoperitoneum was also studied. METHODS: This prospective, double-blind, randomised study included 148 patients of American Society of Anesthesiologists physical status class I and II undergoing laparoscopic surgeries. They were allocated into two groups: group S (standard) (number (n) = 73) had the IAP maintained between 13-15 mmHg; group L (low) had an IAP of 6-8 mmHg (n = 75). CSA of right IJV was measured before induction of anaesthesia (T1), 5 min after intubation (T2), 5 min after pneumoperitoneum (T3), before desufflation (T4) and 5 min prior to extubation (T5). Chi-square test, and Student’s paired and unpaired t test were used for statistical analysis. RESULTS: The increase in IJV CSA at T3 when compared to T2 was statistically significant in both the groups (P < 0.001). On desufflation, the change in IJV CSA showed significant decrease in T5 value than T4 value in both the groups (P < 0.001). However, the percentage change in the IJV CSA was more in group S (35.4%) than group L (21.2%). CONCLUSION: CSA of IJV increased significantly even with lower IAP of 6-8 mmHg. Laparoscopic surgery can be performed conveniently even at low IAP. Wolters Kluwer - Medknow 2022-09 2022-09-20 /pmc/articles/PMC9662095/ /pubmed/36388446 http://dx.doi.org/10.4103/ija.ija_350_22 Text en Copyright: © 2022 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ponduru, Supraja
Nanda, Ananya
Pakhare, Vandana
Ramchandran, Gopinath
Sangineni, Kalyani S.
Priyanka, R. Devi Sai
The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study
title The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study
title_full The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study
title_fullStr The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study
title_full_unstemmed The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study
title_short The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study
title_sort effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – a prospective double-blind, randomised study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9662095/
https://www.ncbi.nlm.nih.gov/pubmed/36388446
http://dx.doi.org/10.4103/ija.ija_350_22
work_keys_str_mv AT pondurusupraja theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT nandaananya theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT pakharevandana theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT ramchandrangopinath theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT sanginenikalyanis theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT priyankardevisai theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT pondurusupraja effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT nandaananya effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT pakharevandana effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT ramchandrangopinath effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT sanginenikalyanis effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy
AT priyankardevisai effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy