Cargando…
The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study
BACKGROUND AND AIMS: During laparoscopic surgeries, pneumoperitoneum increases intraabdominal pressure (IAP) which can increase the central venous pressure (CVP), and significant haemodynamic changes. In this study, we evaluated the effect of two different pressures of pneumoperitoneum, standard (13...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9662095/ https://www.ncbi.nlm.nih.gov/pubmed/36388446 http://dx.doi.org/10.4103/ija.ija_350_22 |
_version_ | 1784830617867780096 |
---|---|
author | Ponduru, Supraja Nanda, Ananya Pakhare, Vandana Ramchandran, Gopinath Sangineni, Kalyani S. Priyanka, R. Devi Sai |
author_facet | Ponduru, Supraja Nanda, Ananya Pakhare, Vandana Ramchandran, Gopinath Sangineni, Kalyani S. Priyanka, R. Devi Sai |
author_sort | Ponduru, Supraja |
collection | PubMed |
description | BACKGROUND AND AIMS: During laparoscopic surgeries, pneumoperitoneum increases intraabdominal pressure (IAP) which can increase the central venous pressure (CVP), and significant haemodynamic changes. In this study, we evaluated the effect of two different pressures of pneumoperitoneum, standard (13-15 mmHg), and low (6-8 mmHg) on the cross-sectional area (CSA) of the internal jugular vein (IJV) using ultrasonography, haemodynamic changes and duration of surgery. Surgeon’s comfort and feasibility of performing laparoscopic surgeries with low pressure pneumoperitoneum was also studied. METHODS: This prospective, double-blind, randomised study included 148 patients of American Society of Anesthesiologists physical status class I and II undergoing laparoscopic surgeries. They were allocated into two groups: group S (standard) (number (n) = 73) had the IAP maintained between 13-15 mmHg; group L (low) had an IAP of 6-8 mmHg (n = 75). CSA of right IJV was measured before induction of anaesthesia (T1), 5 min after intubation (T2), 5 min after pneumoperitoneum (T3), before desufflation (T4) and 5 min prior to extubation (T5). Chi-square test, and Student’s paired and unpaired t test were used for statistical analysis. RESULTS: The increase in IJV CSA at T3 when compared to T2 was statistically significant in both the groups (P < 0.001). On desufflation, the change in IJV CSA showed significant decrease in T5 value than T4 value in both the groups (P < 0.001). However, the percentage change in the IJV CSA was more in group S (35.4%) than group L (21.2%). CONCLUSION: CSA of IJV increased significantly even with lower IAP of 6-8 mmHg. Laparoscopic surgery can be performed conveniently even at low IAP. |
format | Online Article Text |
id | pubmed-9662095 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-96620952022-11-15 The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study Ponduru, Supraja Nanda, Ananya Pakhare, Vandana Ramchandran, Gopinath Sangineni, Kalyani S. Priyanka, R. Devi Sai Indian J Anaesth Original Article BACKGROUND AND AIMS: During laparoscopic surgeries, pneumoperitoneum increases intraabdominal pressure (IAP) which can increase the central venous pressure (CVP), and significant haemodynamic changes. In this study, we evaluated the effect of two different pressures of pneumoperitoneum, standard (13-15 mmHg), and low (6-8 mmHg) on the cross-sectional area (CSA) of the internal jugular vein (IJV) using ultrasonography, haemodynamic changes and duration of surgery. Surgeon’s comfort and feasibility of performing laparoscopic surgeries with low pressure pneumoperitoneum was also studied. METHODS: This prospective, double-blind, randomised study included 148 patients of American Society of Anesthesiologists physical status class I and II undergoing laparoscopic surgeries. They were allocated into two groups: group S (standard) (number (n) = 73) had the IAP maintained between 13-15 mmHg; group L (low) had an IAP of 6-8 mmHg (n = 75). CSA of right IJV was measured before induction of anaesthesia (T1), 5 min after intubation (T2), 5 min after pneumoperitoneum (T3), before desufflation (T4) and 5 min prior to extubation (T5). Chi-square test, and Student’s paired and unpaired t test were used for statistical analysis. RESULTS: The increase in IJV CSA at T3 when compared to T2 was statistically significant in both the groups (P < 0.001). On desufflation, the change in IJV CSA showed significant decrease in T5 value than T4 value in both the groups (P < 0.001). However, the percentage change in the IJV CSA was more in group S (35.4%) than group L (21.2%). CONCLUSION: CSA of IJV increased significantly even with lower IAP of 6-8 mmHg. Laparoscopic surgery can be performed conveniently even at low IAP. Wolters Kluwer - Medknow 2022-09 2022-09-20 /pmc/articles/PMC9662095/ /pubmed/36388446 http://dx.doi.org/10.4103/ija.ija_350_22 Text en Copyright: © 2022 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Ponduru, Supraja Nanda, Ananya Pakhare, Vandana Ramchandran, Gopinath Sangineni, Kalyani S. Priyanka, R. Devi Sai The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study |
title | The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study |
title_full | The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study |
title_fullStr | The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study |
title_full_unstemmed | The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study |
title_short | The effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – A prospective double-blind, randomised study |
title_sort | effect of different pressures of pneumoperitoneum on the dimensions of internal jugular vein – a prospective double-blind, randomised study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9662095/ https://www.ncbi.nlm.nih.gov/pubmed/36388446 http://dx.doi.org/10.4103/ija.ija_350_22 |
work_keys_str_mv | AT pondurusupraja theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT nandaananya theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT pakharevandana theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT ramchandrangopinath theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT sanginenikalyanis theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT priyankardevisai theeffectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT pondurusupraja effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT nandaananya effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT pakharevandana effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT ramchandrangopinath effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT sanginenikalyanis effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy AT priyankardevisai effectofdifferentpressuresofpneumoperitoneumonthedimensionsofinternaljugularveinaprospectivedoubleblindrandomisedstudy |