Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report
Fibrin glue is a topical agent widely used for hemostasis, wound healing, and surgical adhesion. Complications of fibrin glue itself are extremely rare because it is absorbed over time, but can occur as a result of inappropriate application. We report a case of a postoperative complication caused by...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Cleft Palate-Craniofacial Association
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9663261/ https://www.ncbi.nlm.nih.gov/pubmed/36373257 http://dx.doi.org/10.7181/acfs.2022.00829 |
_version_ | 1784830834251923456 |
---|---|
author | Shin, Jin Yong Lee, Nae-Ho Kim, Min-Seok Roh, Si-Gyun Chung, Yoon Kyu |
author_facet | Shin, Jin Yong Lee, Nae-Ho Kim, Min-Seok Roh, Si-Gyun Chung, Yoon Kyu |
author_sort | Shin, Jin Yong |
collection | PubMed |
description | Fibrin glue is a topical agent widely used for hemostasis, wound healing, and surgical adhesion. Complications of fibrin glue itself are extremely rare because it is absorbed over time, but can occur as a result of inappropriate application. We report a case of a postoperative complication caused by inappropriate application of fibrin glue in blow-out fracture surgery. A 65-year-old male patient presented with periorbital swelling and an open wound on the right infraorbital area. Computed tomography showed a right orbital floor fracture. After reduction of the herniated tissue into the orbit, an implant was inserted and fibrin glue was applied to stabilize the implant. This procedure was performed without difficulty, but the patient complained of persistent diplopia and limited eyeball movement after surgery. An imaging study showed a mass-like lesion, which was not a hematoma, in the orbital cavity. In a second operation, the mass was identified as clotted fibrin glue that had not been applied properly. After removal, the patient’s symptoms were relieved without further complications. Appropriate and careful application of fibrin glue is necessary to avoid unnecessary complications. |
format | Online Article Text |
id | pubmed-9663261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Cleft Palate-Craniofacial Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-96632612022-11-28 Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report Shin, Jin Yong Lee, Nae-Ho Kim, Min-Seok Roh, Si-Gyun Chung, Yoon Kyu Arch Craniofac Surg Case Report Fibrin glue is a topical agent widely used for hemostasis, wound healing, and surgical adhesion. Complications of fibrin glue itself are extremely rare because it is absorbed over time, but can occur as a result of inappropriate application. We report a case of a postoperative complication caused by inappropriate application of fibrin glue in blow-out fracture surgery. A 65-year-old male patient presented with periorbital swelling and an open wound on the right infraorbital area. Computed tomography showed a right orbital floor fracture. After reduction of the herniated tissue into the orbit, an implant was inserted and fibrin glue was applied to stabilize the implant. This procedure was performed without difficulty, but the patient complained of persistent diplopia and limited eyeball movement after surgery. An imaging study showed a mass-like lesion, which was not a hematoma, in the orbital cavity. In a second operation, the mass was identified as clotted fibrin glue that had not been applied properly. After removal, the patient’s symptoms were relieved without further complications. Appropriate and careful application of fibrin glue is necessary to avoid unnecessary complications. Korean Cleft Palate-Craniofacial Association 2022-10 2022-10-20 /pmc/articles/PMC9663261/ /pubmed/36373257 http://dx.doi.org/10.7181/acfs.2022.00829 Text en Copyright © 2022 Korean Cleft Palate-Craniofacial Association https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Shin, Jin Yong Lee, Nae-Ho Kim, Min-Seok Roh, Si-Gyun Chung, Yoon Kyu Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report |
title | Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report |
title_full | Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report |
title_fullStr | Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report |
title_full_unstemmed | Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report |
title_short | Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report |
title_sort | limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9663261/ https://www.ncbi.nlm.nih.gov/pubmed/36373257 http://dx.doi.org/10.7181/acfs.2022.00829 |
work_keys_str_mv | AT shinjinyong limitedeyemovementcausedbyclumpingoffibringlueusedinblowoutfracturesurgeryacarereport AT leenaeho limitedeyemovementcausedbyclumpingoffibringlueusedinblowoutfracturesurgeryacarereport AT kimminseok limitedeyemovementcausedbyclumpingoffibringlueusedinblowoutfracturesurgeryacarereport AT rohsigyun limitedeyemovementcausedbyclumpingoffibringlueusedinblowoutfracturesurgeryacarereport AT chungyoonkyu limitedeyemovementcausedbyclumpingoffibringlueusedinblowoutfracturesurgeryacarereport |