Cargando…
A novel method of manual positioning based on anatomical mark (shoulder-to-shoulder) to prevent postoperative leg-length discrepancy for femoral neck fractures in hip arthroplasty
OBJECTIVE: To determine whether the two lower extremities are of equal length after hip arthroplasty for femoral neck fractures, we developed a novel method of manual positioning based on anatomical mark (shoulder-to-shoulder) in hip arthroplasty. METHODS: Patients with femoral neck fractures requir...
Autores principales: | Zhang, Jin-shan, Zheng, Yong-qiang, Liu, Xiao-feng, Xu, Yong-quan, Fang, Yang-zhen, Lin, Zhen-yu, Lin, Liang, Xu, You-jia |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9663648/ https://www.ncbi.nlm.nih.gov/pubmed/36386505 http://dx.doi.org/10.3389/fsurg.2022.1030657 |
Ejemplares similares
-
Intraoperative method of femoral head central measurement to prevent leg length discrepancy following hemiarthroplasty
por: Hu, Hongxin, et al.
Publicado: (2023) -
The effectiveness and influencing factors of the “Y” line technique in reducing the leg length discrepancy after total hip arthroplasty
por: Jin, Wenshu, et al.
Publicado: (2023) -
Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty
por: Chen, Xing, et al.
Publicado: (2022) -
Corrigendum: Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty
por: Chen, Xing, et al.
Publicado: (2022) -
Complications and revisions in anatomic and reverse short stem shoulder arthroplasty
por: Loew, Markus, et al.
Publicado: (2023)