Cargando…

Cost-Effectiveness of a Real-Time Continuous Glucose Monitoring System Versus Self-Monitoring of Blood Glucose in People with Type 2 Diabetes on Insulin Therapy in the UK

INTRODUCTION: Real-time continuous glucose monitoring (rt-CGM) involves the measurement and display of glucose concentrations, potentially improving glucose control among insulin-treated patients with type 2 diabetes (T2D). The present analysis aimed to conduct a cost-effectiveness analysis of rt-CG...

Descripción completa

Detalles Bibliográficos
Autores principales: Isitt, John J., Roze, Stéphane, Sharland, Helen, Cogswell, Greg, Alshannaq, Hamza, Norman, Gregory J., Lynch, Peter M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9663778/
https://www.ncbi.nlm.nih.gov/pubmed/36258158
http://dx.doi.org/10.1007/s13300-022-01324-x
Descripción
Sumario:INTRODUCTION: Real-time continuous glucose monitoring (rt-CGM) involves the measurement and display of glucose concentrations, potentially improving glucose control among insulin-treated patients with type 2 diabetes (T2D). The present analysis aimed to conduct a cost-effectiveness analysis of rt-CGM versus self-monitoring of blood glucose (SMBG) based on a USA retrospective cohort study in insulin-treated people with T2D adapted to the UK. METHODS: Long-term costs and clinical outcomes were estimated using the CORE Diabetes Model, with clinical input data sourced from a retrospective cohort study. Patients were assumed to have a baseline glycated hemoglobin (HbA1c) of 8.3%. Patients using rt-CGM were assumed to have a 0.56% reduction in HbA1c based on the mean difference between groups after 12 months of follow-up. Reduced fingerstick testing when using rt-CGM was associated with a quality of life (QoL) benefit. The analysis was performed over a lifetime time horizon from a National Health Service (NHS) perspective, including only direct costs from published data. Future costs and clinical outcomes were discounted at 3.5% per annum. Extensive sensitivity analyses were performed. RESULTS: Projections showed that rt-CGM was associated with increased quality-adjusted life expectancy of 0.731 quality-adjusted life years (QALYs) and increased mean total lifetime costs of Great British pounds (GBP) 2694, and an incremental cost-effectiveness ratio of GBP 3684 per QALY compared with SMBG. Key drivers of outcomes included HbA1c reduction and reduced fingerstick testing QoL benefit. CONCLUSIONS: Over patient lifetimes, rt-CGM was associated with improved clinical outcomes and is highly likely to be cost effective versus SMBG in people with T2D on insulin therapy in the UK. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13300-022-01324-x.