Cargando…
Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis
PURPOSE: To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries. METHODS: This retrospective case series analysed 41 patients implante...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9664806/ https://www.ncbi.nlm.nih.gov/pubmed/36376808 http://dx.doi.org/10.1186/s12886-022-02653-y |
_version_ | 1784831177559900160 |
---|---|
author | Sánchez Trancón, Angel Cerpa Manito, Santiago Torrado Sierra, Oscar Baptista, António Manuel Serra, Pedro Miguel |
author_facet | Sánchez Trancón, Angel Cerpa Manito, Santiago Torrado Sierra, Oscar Baptista, António Manuel Serra, Pedro Miguel |
author_sort | Sánchez Trancón, Angel |
collection | PubMed |
description | PURPOSE: To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries. METHODS: This retrospective case series analysed 41 patients implanted with a spherical ICL (sICL) in one eye and an equal sized toric ICL (tICL) in the fellow eye. The anatomical and ICL-related parameters were assessed using anterior-segment optical coherence tomography (AS-OCT Visante, Zeiss Meditec AG) and optical tomography (Pentacam, OCULUS). The influence of the anatomical and ICL-related parameters on the vault was determined using generalised estimating equations (GEE) to incorporate inter-eye correlations. RESULTS: Postoperative spherical equivalent was within ± 0.50D in 66% and 83% of the eyes, respectively implanted with sICL and tICL. The efficacy index in the sICL group was 1.06 and 1.14 in the tICL group. The mean inter-eye vault difference was -1.46 µm, anatomical and ICL-related parameters showed similar associations with the vault for sICL and tICL. The GEE identified the ICL size minus the anterior chamber width, the ICL spherical power and ICL central thickness as significant factors influencing the vault. CONCLUSIONS: Spherical and toric ICL showed good efficacy for the correction of myopia and astigmatism. Patients implanted bilaterally with sICL and tICL tend to present similar vaults. The vault produced by both types of ICL was mainly regulated by the oversizing of the ICL. This suggests that the ICL geometry (spherical vs toric) is a factor with limited influence on the vault, thus the sizing method of a sICL and tICL should be similar. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02653-y. |
format | Online Article Text |
id | pubmed-9664806 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-96648062022-11-15 Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis Sánchez Trancón, Angel Cerpa Manito, Santiago Torrado Sierra, Oscar Baptista, António Manuel Serra, Pedro Miguel BMC Ophthalmol Research PURPOSE: To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries. METHODS: This retrospective case series analysed 41 patients implanted with a spherical ICL (sICL) in one eye and an equal sized toric ICL (tICL) in the fellow eye. The anatomical and ICL-related parameters were assessed using anterior-segment optical coherence tomography (AS-OCT Visante, Zeiss Meditec AG) and optical tomography (Pentacam, OCULUS). The influence of the anatomical and ICL-related parameters on the vault was determined using generalised estimating equations (GEE) to incorporate inter-eye correlations. RESULTS: Postoperative spherical equivalent was within ± 0.50D in 66% and 83% of the eyes, respectively implanted with sICL and tICL. The efficacy index in the sICL group was 1.06 and 1.14 in the tICL group. The mean inter-eye vault difference was -1.46 µm, anatomical and ICL-related parameters showed similar associations with the vault for sICL and tICL. The GEE identified the ICL size minus the anterior chamber width, the ICL spherical power and ICL central thickness as significant factors influencing the vault. CONCLUSIONS: Spherical and toric ICL showed good efficacy for the correction of myopia and astigmatism. Patients implanted bilaterally with sICL and tICL tend to present similar vaults. The vault produced by both types of ICL was mainly regulated by the oversizing of the ICL. This suggests that the ICL geometry (spherical vs toric) is a factor with limited influence on the vault, thus the sizing method of a sICL and tICL should be similar. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02653-y. BioMed Central 2022-11-15 /pmc/articles/PMC9664806/ /pubmed/36376808 http://dx.doi.org/10.1186/s12886-022-02653-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Sánchez Trancón, Angel Cerpa Manito, Santiago Torrado Sierra, Oscar Baptista, António Manuel Serra, Pedro Miguel Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis |
title | Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis |
title_full | Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis |
title_fullStr | Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis |
title_full_unstemmed | Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis |
title_short | Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis |
title_sort | vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9664806/ https://www.ncbi.nlm.nih.gov/pubmed/36376808 http://dx.doi.org/10.1186/s12886-022-02653-y |
work_keys_str_mv | AT sancheztranconangel vaultdifferencesineyesimplantedwithsphericalandtoricimplantablecollamerlensesanintereyeanalysis AT cerpamanitosantiago vaultdifferencesineyesimplantedwithsphericalandtoricimplantablecollamerlensesanintereyeanalysis AT torradosierraoscar vaultdifferencesineyesimplantedwithsphericalandtoricimplantablecollamerlensesanintereyeanalysis AT baptistaantoniomanuel vaultdifferencesineyesimplantedwithsphericalandtoricimplantablecollamerlensesanintereyeanalysis AT serrapedromiguel vaultdifferencesineyesimplantedwithsphericalandtoricimplantablecollamerlensesanintereyeanalysis |