Cargando…
Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case
Reconstruction of functional occlusion in case of a large surgical defect of the mandible involving partial mandibulectomy remains a significant challenge to the maxillofacial surgeon and prosthodontist. Removable appliances and the conventional implant-supported prosthesis are precluded in this cas...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9667493/ https://www.ncbi.nlm.nih.gov/pubmed/36407774 |
_version_ | 1784831736551571456 |
---|---|
author | Gupta, Alka Agrawal, Deepak Jain, Deshraj Gedam, Unnati Varma, Amit |
author_facet | Gupta, Alka Agrawal, Deepak Jain, Deshraj Gedam, Unnati Varma, Amit |
author_sort | Gupta, Alka |
collection | PubMed |
description | Reconstruction of functional occlusion in case of a large surgical defect of the mandible involving partial mandibulectomy remains a significant challenge to the maxillofacial surgeon and prosthodontist. Removable appliances and the conventional implant-supported prosthesis are precluded in this case due to the absence of normal anatomical contours of the bone. In recent years, due to the advancement of technology, bone graft reconstruction with computer-guided rehabilitation of the functional occlusion has been advocated to reverse the debilitating effects of the hemimandibulectomy defect. This clinical report describes the prosthodontic management of fibular graft reconstructed mandible by computer-aided design–computer-aided manufacturing guided implant-supported prosthesis. |
format | Online Article Text |
id | pubmed-9667493 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-96674932022-11-17 Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case Gupta, Alka Agrawal, Deepak Jain, Deshraj Gedam, Unnati Varma, Amit Dent Res J (Isfahan) Case Report Reconstruction of functional occlusion in case of a large surgical defect of the mandible involving partial mandibulectomy remains a significant challenge to the maxillofacial surgeon and prosthodontist. Removable appliances and the conventional implant-supported prosthesis are precluded in this case due to the absence of normal anatomical contours of the bone. In recent years, due to the advancement of technology, bone graft reconstruction with computer-guided rehabilitation of the functional occlusion has been advocated to reverse the debilitating effects of the hemimandibulectomy defect. This clinical report describes the prosthodontic management of fibular graft reconstructed mandible by computer-aided design–computer-aided manufacturing guided implant-supported prosthesis. Wolters Kluwer - Medknow 2022-09-26 /pmc/articles/PMC9667493/ /pubmed/36407774 Text en Copyright: © 2022 Dental Research Journal https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Gupta, Alka Agrawal, Deepak Jain, Deshraj Gedam, Unnati Varma, Amit Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case |
title | Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case |
title_full | Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case |
title_fullStr | Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case |
title_full_unstemmed | Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case |
title_short | Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case |
title_sort | design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: a 7-year follow-up of a case |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9667493/ https://www.ncbi.nlm.nih.gov/pubmed/36407774 |
work_keys_str_mv | AT guptaalka designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase AT agrawaldeepak designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase AT jaindeshraj designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase AT gedamunnati designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase AT varmaamit designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase |