Cargando…

Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case

Reconstruction of functional occlusion in case of a large surgical defect of the mandible involving partial mandibulectomy remains a significant challenge to the maxillofacial surgeon and prosthodontist. Removable appliances and the conventional implant-supported prosthesis are precluded in this cas...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Alka, Agrawal, Deepak, Jain, Deshraj, Gedam, Unnati, Varma, Amit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9667493/
https://www.ncbi.nlm.nih.gov/pubmed/36407774
_version_ 1784831736551571456
author Gupta, Alka
Agrawal, Deepak
Jain, Deshraj
Gedam, Unnati
Varma, Amit
author_facet Gupta, Alka
Agrawal, Deepak
Jain, Deshraj
Gedam, Unnati
Varma, Amit
author_sort Gupta, Alka
collection PubMed
description Reconstruction of functional occlusion in case of a large surgical defect of the mandible involving partial mandibulectomy remains a significant challenge to the maxillofacial surgeon and prosthodontist. Removable appliances and the conventional implant-supported prosthesis are precluded in this case due to the absence of normal anatomical contours of the bone. In recent years, due to the advancement of technology, bone graft reconstruction with computer-guided rehabilitation of the functional occlusion has been advocated to reverse the debilitating effects of the hemimandibulectomy defect. This clinical report describes the prosthodontic management of fibular graft reconstructed mandible by computer-aided design–computer-aided manufacturing guided implant-supported prosthesis.
format Online
Article
Text
id pubmed-9667493
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-96674932022-11-17 Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case Gupta, Alka Agrawal, Deepak Jain, Deshraj Gedam, Unnati Varma, Amit Dent Res J (Isfahan) Case Report Reconstruction of functional occlusion in case of a large surgical defect of the mandible involving partial mandibulectomy remains a significant challenge to the maxillofacial surgeon and prosthodontist. Removable appliances and the conventional implant-supported prosthesis are precluded in this case due to the absence of normal anatomical contours of the bone. In recent years, due to the advancement of technology, bone graft reconstruction with computer-guided rehabilitation of the functional occlusion has been advocated to reverse the debilitating effects of the hemimandibulectomy defect. This clinical report describes the prosthodontic management of fibular graft reconstructed mandible by computer-aided design–computer-aided manufacturing guided implant-supported prosthesis. Wolters Kluwer - Medknow 2022-09-26 /pmc/articles/PMC9667493/ /pubmed/36407774 Text en Copyright: © 2022 Dental Research Journal https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Case Report
Gupta, Alka
Agrawal, Deepak
Jain, Deshraj
Gedam, Unnati
Varma, Amit
Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case
title Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case
title_full Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case
title_fullStr Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case
title_full_unstemmed Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case
title_short Design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: A 7-year follow-up of a case
title_sort design–computer-aided manufacturing guided implant-supported prosthesis in a fibular graft reconstructed mandible: a 7-year follow-up of a case
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9667493/
https://www.ncbi.nlm.nih.gov/pubmed/36407774
work_keys_str_mv AT guptaalka designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase
AT agrawaldeepak designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase
AT jaindeshraj designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase
AT gedamunnati designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase
AT varmaamit designcomputeraidedmanufacturingguidedimplantsupportedprosthesisinafibulargraftreconstructedmandiblea7yearfollowupofacase