Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study
INTRODUCTION: Manual counting of respiratory rate (RR) in children is challenging for health workers and can result in misdiagnosis of pneumonia. Some novel RR counting devices automate the counting of RR and classification of fast breathing. The absence of an appropriate reference standard to evalu...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9668034/ https://www.ncbi.nlm.nih.gov/pubmed/36379660 http://dx.doi.org/10.1136/bmjopen-2022-067389 |
_version_ | 1784831826925191168 |
---|---|
author | Khan, Ahad Mahmud Ahmed, Salahuddin Chowdhury, Nabidul Haque Islam, Md Shafiqul McCollum, Eric D King, Carina Shi, Ting Nahar, Kamrun Simpson, Robynne Ahmed, Ayaz Rahman, Md Mozibur Baqui, Abdullah H Cunningham, Steve Campbell, Harry |
author_facet | Khan, Ahad Mahmud Ahmed, Salahuddin Chowdhury, Nabidul Haque Islam, Md Shafiqul McCollum, Eric D King, Carina Shi, Ting Nahar, Kamrun Simpson, Robynne Ahmed, Ayaz Rahman, Md Mozibur Baqui, Abdullah H Cunningham, Steve Campbell, Harry |
author_sort | Khan, Ahad Mahmud |
collection | PubMed |
description | INTRODUCTION: Manual counting of respiratory rate (RR) in children is challenging for health workers and can result in misdiagnosis of pneumonia. Some novel RR counting devices automate the counting of RR and classification of fast breathing. The absence of an appropriate reference standard to evaluate the performance of these devices is a challenge. If good quality videos could be captured, with RR interpretation from these videos systematically conducted by an expert panel, it could act as a reference standard. This study is designed to develop a video expert panel (VEP) as a reference standard to evaluate RR counting for identifying pneumonia in children. METHODS AND ANALYSIS: Using a cross-sectional design, we will enrol children aged 0–59 months presenting with suspected pneumonia at different levels of health facilities in Dhaka and Sylhet, Bangladesh. We will videorecord a physician/health worker counting RR manually and also using an automated RR counter (Children’s Automated Respiration Monitor) from each child. We will establish a standard operating procedure for capturing quality videos, make a set of reference videos, and train and standardise the VEP members using the reference videos. After that, we will assess the performance of the VEP as a reference standard to evaluate RR counting. We will calculate the mean difference and proportions of agreement within±2 breaths per minute and create Bland-Altman plots with limits of agreement between VEP members. ETHICS AND DISSEMINATION: The study protocol was approved by the National Research Ethics Committee of Bangladesh Medical Research Council, Bangladesh (registration number: 39315022021) and Edinburgh Medical School Research Ethics Committee (EMREC), Edinburgh, UK (REC Reference: 21-EMREC-040). Dissemination of the study findings will be through conference presentations and publications in peer-reviewed scientific journals. |
format | Online Article Text |
id | pubmed-9668034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-96680342022-11-17 Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study Khan, Ahad Mahmud Ahmed, Salahuddin Chowdhury, Nabidul Haque Islam, Md Shafiqul McCollum, Eric D King, Carina Shi, Ting Nahar, Kamrun Simpson, Robynne Ahmed, Ayaz Rahman, Md Mozibur Baqui, Abdullah H Cunningham, Steve Campbell, Harry BMJ Open Paediatrics INTRODUCTION: Manual counting of respiratory rate (RR) in children is challenging for health workers and can result in misdiagnosis of pneumonia. Some novel RR counting devices automate the counting of RR and classification of fast breathing. The absence of an appropriate reference standard to evaluate the performance of these devices is a challenge. If good quality videos could be captured, with RR interpretation from these videos systematically conducted by an expert panel, it could act as a reference standard. This study is designed to develop a video expert panel (VEP) as a reference standard to evaluate RR counting for identifying pneumonia in children. METHODS AND ANALYSIS: Using a cross-sectional design, we will enrol children aged 0–59 months presenting with suspected pneumonia at different levels of health facilities in Dhaka and Sylhet, Bangladesh. We will videorecord a physician/health worker counting RR manually and also using an automated RR counter (Children’s Automated Respiration Monitor) from each child. We will establish a standard operating procedure for capturing quality videos, make a set of reference videos, and train and standardise the VEP members using the reference videos. After that, we will assess the performance of the VEP as a reference standard to evaluate RR counting. We will calculate the mean difference and proportions of agreement within±2 breaths per minute and create Bland-Altman plots with limits of agreement between VEP members. ETHICS AND DISSEMINATION: The study protocol was approved by the National Research Ethics Committee of Bangladesh Medical Research Council, Bangladesh (registration number: 39315022021) and Edinburgh Medical School Research Ethics Committee (EMREC), Edinburgh, UK (REC Reference: 21-EMREC-040). Dissemination of the study findings will be through conference presentations and publications in peer-reviewed scientific journals. BMJ Publishing Group 2022-11-15 /pmc/articles/PMC9668034/ /pubmed/36379660 http://dx.doi.org/10.1136/bmjopen-2022-067389 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY. Published by BMJ. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Paediatrics Khan, Ahad Mahmud Ahmed, Salahuddin Chowdhury, Nabidul Haque Islam, Md Shafiqul McCollum, Eric D King, Carina Shi, Ting Nahar, Kamrun Simpson, Robynne Ahmed, Ayaz Rahman, Md Mozibur Baqui, Abdullah H Cunningham, Steve Campbell, Harry Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study |
title | Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study |
title_full | Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study |
title_fullStr | Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study |
title_full_unstemmed | Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study |
title_short | Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study |
title_sort | developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis: protocol for a cross-sectional study |
topic | Paediatrics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9668034/ https://www.ncbi.nlm.nih.gov/pubmed/36379660 http://dx.doi.org/10.1136/bmjopen-2022-067389 |
work_keys_str_mv | AT khanahadmahmud developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT ahmedsalahuddin developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT chowdhurynabidulhaque developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT islammdshafiqul developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT mccollumericd developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT kingcarina developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT shiting developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT naharkamrun developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT simpsonrobynne developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT ahmedayaz developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT rahmanmdmozibur developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT baquiabdullahh developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT cunninghamsteve developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy AT campbellharry developingavideoexpertpanelasareferencestandardtoevaluaterespiratoryratecountinginpaediatricpneumoniadiagnosisprotocolforacrosssectionalstudy |