Cargando…

T1w/FLAIR ratio standardization as a myelin marker in MS patients

INTRODUCTION: Calculation of a T1w/T2w ratio was introduced as a proxy for myelin integrity in the brain of multiple sclerosis (MS) patients. Since nowadays 3D FLAIR is commonly used for lesion detection instead of T2w images, we introduce a T1w/FLAIR ratio as an alternative for the T1w/T2w ratio. O...

Descripción completa

Detalles Bibliográficos
Autores principales: Cappelle, S., Pareto, D., Sunaert, S., Smets, I., Laenen, A., Dubois, B., Demaerel, Ph.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9668645/
https://www.ncbi.nlm.nih.gov/pubmed/36451354
http://dx.doi.org/10.1016/j.nicl.2022.103248
_version_ 1784831959774527488
author Cappelle, S.
Pareto, D.
Sunaert, S.
Smets, I.
Laenen, A.
Dubois, B.
Demaerel, Ph.
author_facet Cappelle, S.
Pareto, D.
Sunaert, S.
Smets, I.
Laenen, A.
Dubois, B.
Demaerel, Ph.
author_sort Cappelle, S.
collection PubMed
description INTRODUCTION: Calculation of a T1w/T2w ratio was introduced as a proxy for myelin integrity in the brain of multiple sclerosis (MS) patients. Since nowadays 3D FLAIR is commonly used for lesion detection instead of T2w images, we introduce a T1w/FLAIR ratio as an alternative for the T1w/T2w ratio. OBJECTIVES: Bias and intensity variation are widely present between different scanners, between subjects and within subjects over time in T1w, T2w and FLAIR images. We present a standardized method for calculating a histogram calibrated T1w/FLAIR ratio to reduce bias and intensity variation in MR sequences from different scanners and at different time-points. MATERIAL AND METHODS: 207 Relapsing Remitting MS patients were scanned on 4 different 3 T scanners with a protocol including 3D T1w, 2D T2w and 3D FLAIR images. After bias correction, T1w/FLAIR ratio maps and T1w/T2w ratio maps were calculated in 4 different ways: without calibration, with linear histogram calibration as described by Ganzetti et al. (2014), and by using 2 methods of non-linear histogram calibration. The first nonlinear calibration uses a template of extra-cerebral tissue and cerebrospinal fluid (CSF) brought from Montreal Neurological Institute (MNI) space to subject space; for the second nonlinear method we used an extra-cerebral tissue and CSF template of our own subjects. Additionally, we segmented several brain structures such as Normal Appearing White Matter (NAWM), Normal Appearing Grey Matter (NAGM), corpus callosum, thalami and MS lesions using Freesurfer and Samseg. RESULTS: The coefficient of variation of T1w/FLAIR ratio in NAWM for the no calibrated, linear, and 2 nonlinear calibration methods were respectively 24, 19.1, 9.5, 13.8. The nonlinear methods of calibration showed the best results for calculating the T1w/FLAIR ratio with a smaller dispersion of the data and a smaller overlap of T1w/FLAIR ratio in the different segmented brain structures. T1w/T2w and T1w/FLAIR ratios showed a wider range of values compared to MTR values. CONCLUSIONS: Calibration of T1w/T2w and T1w/FLAIR ratio maps is imperative to account for the sources of variation described above. The nonlinear calibration methods showed the best reduction of between-subject and within-subject variability. The T1w/T2w and T1w/FLAIR ratio seem to be more sensitive to smaller changes in tissue integrity than MTR. Future work is needed to determine the exact substrate of T1w/FLAIR ratio and to obtain correlations with clinical outcome.
format Online
Article
Text
id pubmed-9668645
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-96686452022-11-18 T1w/FLAIR ratio standardization as a myelin marker in MS patients Cappelle, S. Pareto, D. Sunaert, S. Smets, I. Laenen, A. Dubois, B. Demaerel, Ph. Neuroimage Clin Regular Article INTRODUCTION: Calculation of a T1w/T2w ratio was introduced as a proxy for myelin integrity in the brain of multiple sclerosis (MS) patients. Since nowadays 3D FLAIR is commonly used for lesion detection instead of T2w images, we introduce a T1w/FLAIR ratio as an alternative for the T1w/T2w ratio. OBJECTIVES: Bias and intensity variation are widely present between different scanners, between subjects and within subjects over time in T1w, T2w and FLAIR images. We present a standardized method for calculating a histogram calibrated T1w/FLAIR ratio to reduce bias and intensity variation in MR sequences from different scanners and at different time-points. MATERIAL AND METHODS: 207 Relapsing Remitting MS patients were scanned on 4 different 3 T scanners with a protocol including 3D T1w, 2D T2w and 3D FLAIR images. After bias correction, T1w/FLAIR ratio maps and T1w/T2w ratio maps were calculated in 4 different ways: without calibration, with linear histogram calibration as described by Ganzetti et al. (2014), and by using 2 methods of non-linear histogram calibration. The first nonlinear calibration uses a template of extra-cerebral tissue and cerebrospinal fluid (CSF) brought from Montreal Neurological Institute (MNI) space to subject space; for the second nonlinear method we used an extra-cerebral tissue and CSF template of our own subjects. Additionally, we segmented several brain structures such as Normal Appearing White Matter (NAWM), Normal Appearing Grey Matter (NAGM), corpus callosum, thalami and MS lesions using Freesurfer and Samseg. RESULTS: The coefficient of variation of T1w/FLAIR ratio in NAWM for the no calibrated, linear, and 2 nonlinear calibration methods were respectively 24, 19.1, 9.5, 13.8. The nonlinear methods of calibration showed the best results for calculating the T1w/FLAIR ratio with a smaller dispersion of the data and a smaller overlap of T1w/FLAIR ratio in the different segmented brain structures. T1w/T2w and T1w/FLAIR ratios showed a wider range of values compared to MTR values. CONCLUSIONS: Calibration of T1w/T2w and T1w/FLAIR ratio maps is imperative to account for the sources of variation described above. The nonlinear calibration methods showed the best reduction of between-subject and within-subject variability. The T1w/T2w and T1w/FLAIR ratio seem to be more sensitive to smaller changes in tissue integrity than MTR. Future work is needed to determine the exact substrate of T1w/FLAIR ratio and to obtain correlations with clinical outcome. Elsevier 2022-10-25 /pmc/articles/PMC9668645/ /pubmed/36451354 http://dx.doi.org/10.1016/j.nicl.2022.103248 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Regular Article
Cappelle, S.
Pareto, D.
Sunaert, S.
Smets, I.
Laenen, A.
Dubois, B.
Demaerel, Ph.
T1w/FLAIR ratio standardization as a myelin marker in MS patients
title T1w/FLAIR ratio standardization as a myelin marker in MS patients
title_full T1w/FLAIR ratio standardization as a myelin marker in MS patients
title_fullStr T1w/FLAIR ratio standardization as a myelin marker in MS patients
title_full_unstemmed T1w/FLAIR ratio standardization as a myelin marker in MS patients
title_short T1w/FLAIR ratio standardization as a myelin marker in MS patients
title_sort t1w/flair ratio standardization as a myelin marker in ms patients
topic Regular Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9668645/
https://www.ncbi.nlm.nih.gov/pubmed/36451354
http://dx.doi.org/10.1016/j.nicl.2022.103248
work_keys_str_mv AT cappelles t1wflairratiostandardizationasamyelinmarkerinmspatients
AT paretod t1wflairratiostandardizationasamyelinmarkerinmspatients
AT sunaerts t1wflairratiostandardizationasamyelinmarkerinmspatients
AT smetsi t1wflairratiostandardizationasamyelinmarkerinmspatients
AT laenena t1wflairratiostandardizationasamyelinmarkerinmspatients
AT duboisb t1wflairratiostandardizationasamyelinmarkerinmspatients
AT demaerelph t1wflairratiostandardizationasamyelinmarkerinmspatients