Cargando…

Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System

PURPOSE: The purpose of this study was to develop and test a programmable closed-loop system for tracking, modulating, and assessing dynamic iris behavior, including in the mid-dilated position. METHODS: A programmable closed-loop iris control system was developed by customizing an ANTERION OCT devi...

Descripción completa

Detalles Bibliográficos
Autores principales: Apolo, Galo, Lazkani, Naim, Zhou, Sarah, Song, Abe E., Pardeshi, Anmol A., Torossian, Lernik, Nguyen, Kent, Weinreb, Robert N., Xu, Benjamin Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9669806/
https://www.ncbi.nlm.nih.gov/pubmed/36374485
http://dx.doi.org/10.1167/tvst.11.11.9
_version_ 1784832205477904384
author Apolo, Galo
Lazkani, Naim
Zhou, Sarah
Song, Abe E.
Pardeshi, Anmol A.
Torossian, Lernik
Nguyen, Kent
Weinreb, Robert N.
Xu, Benjamin Y.
author_facet Apolo, Galo
Lazkani, Naim
Zhou, Sarah
Song, Abe E.
Pardeshi, Anmol A.
Torossian, Lernik
Nguyen, Kent
Weinreb, Robert N.
Xu, Benjamin Y.
author_sort Apolo, Galo
collection PubMed
description PURPOSE: The purpose of this study was to develop and test a programmable closed-loop system for tracking, modulating, and assessing dynamic iris behavior, including in the mid-dilated position. METHODS: A programmable closed-loop iris control system was developed by customizing an ANTERION OCT device (Heidelberg Engineering, Heidelberg, Germany). Custom software was developed to store camera and optical coherence tomography (OCT) images, track pupillary diameter (PD), control a light-emitting diode (LED), and modulate ambient lighting to maintain the iris in a dilated, constricted, or mid-dilated position in real-time. Study participants underwent 3 consecutive 65-second scan sessions. Dynamic iris behavior in the form of peak constriction velocity (PCV) and mid-dilated iris activity (MDIA) were calculated and analyzed offline. RESULTS: Among 58 participants, 56 (96.6%) were eligible for analysis based on achieving and maintaining mean PD within ±10% of the calculated mid-dilated PD. Mean participant age was 49.8 ± 18.9 years. Mean PCV was 3.92 ± 0.83 mm/s, and mean MDIA was 0.37 ± 0.15 mm. The mean difference between the calculated and achieved mid-dilated PD was 0.166 ± 0.192 mm. There were significant negative correlations between PCV and age (slope = −0.022, P < 0.001) and MDIA and age (slope = −0.004, P < 0.001). Success rates were lower (69.0%) but relationships between dynamic iris behavior and age were similar based on achieving and maintaining mean PD within ±5% of the calculated mid-dilated PD. CONCLUSIONS: A programmable closed-loop iris control system can modulate dynamic iris behavior and maintain the iris in a mid-dilated position. Pupillary constriction velocity and iris activity in the mid-dilated position decrease with age. TRANSLATIONAL RELEVANCE: This system can be applied to study dynamic disease processes involving the iris and establish novel biometric measures that could serve as risk factors for acute and chronic primary angle closure glaucoma (PACG).
format Online
Article
Text
id pubmed-9669806
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-96698062022-11-18 Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System Apolo, Galo Lazkani, Naim Zhou, Sarah Song, Abe E. Pardeshi, Anmol A. Torossian, Lernik Nguyen, Kent Weinreb, Robert N. Xu, Benjamin Y. Transl Vis Sci Technol Glaucoma PURPOSE: The purpose of this study was to develop and test a programmable closed-loop system for tracking, modulating, and assessing dynamic iris behavior, including in the mid-dilated position. METHODS: A programmable closed-loop iris control system was developed by customizing an ANTERION OCT device (Heidelberg Engineering, Heidelberg, Germany). Custom software was developed to store camera and optical coherence tomography (OCT) images, track pupillary diameter (PD), control a light-emitting diode (LED), and modulate ambient lighting to maintain the iris in a dilated, constricted, or mid-dilated position in real-time. Study participants underwent 3 consecutive 65-second scan sessions. Dynamic iris behavior in the form of peak constriction velocity (PCV) and mid-dilated iris activity (MDIA) were calculated and analyzed offline. RESULTS: Among 58 participants, 56 (96.6%) were eligible for analysis based on achieving and maintaining mean PD within ±10% of the calculated mid-dilated PD. Mean participant age was 49.8 ± 18.9 years. Mean PCV was 3.92 ± 0.83 mm/s, and mean MDIA was 0.37 ± 0.15 mm. The mean difference between the calculated and achieved mid-dilated PD was 0.166 ± 0.192 mm. There were significant negative correlations between PCV and age (slope = −0.022, P < 0.001) and MDIA and age (slope = −0.004, P < 0.001). Success rates were lower (69.0%) but relationships between dynamic iris behavior and age were similar based on achieving and maintaining mean PD within ±5% of the calculated mid-dilated PD. CONCLUSIONS: A programmable closed-loop iris control system can modulate dynamic iris behavior and maintain the iris in a mid-dilated position. Pupillary constriction velocity and iris activity in the mid-dilated position decrease with age. TRANSLATIONAL RELEVANCE: This system can be applied to study dynamic disease processes involving the iris and establish novel biometric measures that could serve as risk factors for acute and chronic primary angle closure glaucoma (PACG). The Association for Research in Vision and Ophthalmology 2022-11-14 /pmc/articles/PMC9669806/ /pubmed/36374485 http://dx.doi.org/10.1167/tvst.11.11.9 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Glaucoma
Apolo, Galo
Lazkani, Naim
Zhou, Sarah
Song, Abe E.
Pardeshi, Anmol A.
Torossian, Lernik
Nguyen, Kent
Weinreb, Robert N.
Xu, Benjamin Y.
Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System
title Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System
title_full Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System
title_fullStr Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System
title_full_unstemmed Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System
title_short Age-Related Changes in Dynamic Iris Behavior Assessed Using a Programmable Closed-Loop Iris Control System
title_sort age-related changes in dynamic iris behavior assessed using a programmable closed-loop iris control system
topic Glaucoma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9669806/
https://www.ncbi.nlm.nih.gov/pubmed/36374485
http://dx.doi.org/10.1167/tvst.11.11.9
work_keys_str_mv AT apologalo agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT lazkaninaim agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT zhousarah agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT songabee agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT pardeshianmola agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT torossianlernik agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT nguyenkent agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT weinrebrobertn agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem
AT xubenjaminy agerelatedchangesindynamicirisbehaviorassessedusingaprogrammableclosedloopiriscontrolsystem