Cargando…

Voltammetric determination of Molnupiravir used in treatment of the COVID-19 at magnetite nanoparticle modified carbon paste electrode

To reduce the progression of the viral process in patients infected with COVID-19, new treatments and drug active substances are needed. One of these drugs is Molnupiravir (MNP) which has a direct antiviral effect and has also proven to be highly effective in reducing the azopharyngeal SARS-CoV-2 in...

Descripción completa

Detalles Bibliográficos
Autores principales: Vural, Kader, Karakaya, Serkan, Dilgin, Didem Giray, Gökçel, Hatice İsmet, Dilgin, Yusuf
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9671532/
https://www.ncbi.nlm.nih.gov/pubmed/36415585
http://dx.doi.org/10.1016/j.microc.2022.108195
Descripción
Sumario:To reduce the progression of the viral process in patients infected with COVID-19, new treatments and drug active substances are needed. One of these drugs is Molnupiravir (MNP) which has a direct antiviral effect and has also proven to be highly effective in reducing the azopharyngeal SARS-CoV-2 infectious virus and viral RNA. Due to the importance and frequent use of this drug in the treatment of COVID-19, its accurate, quick, and cheap detection in pharmaceutical or biological samples is crucial. In this work, electrochemical behavior and sensitive voltammetric determination of MNP are described using a magnetite nanoparticle modified carbon paste electrode (Fe(3)O(4)@CPE) for the first time. Fe(3)O(4) nanoparticles (NPs) were characterized by recording their transmission electron microscopy (TEM) images, energy dispersive X-ray (EDX), and X-ray diffraction (XRD) spectra. Cyclic voltammetric measurements showed that MNP was irreversibly oxidized at Fe(3)O(4)@CPE at 760 mV in pH 2.0 Britton Robinson buffer solution (BRBS). The peak current of MNP was increased approximately threefold at Fe(3)O(4)@CPE compared to bare CPE due to a good electrocatalytic efficiency of Fe(3)O(4) NPs. According to differential pulse voltammetric studies, the fabricated electrode exhibited a linear range (LR) between 0.25 and 750 µM with sensitivity and limit of detection (LOD) of 4591.0 µA mM(−1) cm(−2) and 0.05 µM, respectively. On the other hand, although lower sensitivity (327.3 µA mM(−1) cm(−2)) was obtained from CV compared to DPV, a wider linear calibration curve between 0.25 and 1500 µM was obtained in CV. Studies performed in tablet samples confirmed that the Fe(3)O(4)@CPE exhibits high applicability for selective and accurate voltammetric determination of MNP in real samples.