Cargando…
Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty
Performance of aeration systems in wastewater treatment plants (WWTP) under process conditions can be monitored with off-gas tests. The ex situ off-gas method transfers activated sludge from an adjacent aeration tank into aerated columns to determine oxygen transfer parameters (e.g., the α-factor)....
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9672027/ https://www.ncbi.nlm.nih.gov/pubmed/35829889 http://dx.doi.org/10.1007/s11356-022-21915-2 |
_version_ | 1784832667908308992 |
---|---|
author | Schwarz, Maximilian Trippel, Jana Engelhart, Markus Wagner, Martin |
author_facet | Schwarz, Maximilian Trippel, Jana Engelhart, Markus Wagner, Martin |
author_sort | Schwarz, Maximilian |
collection | PubMed |
description | Performance of aeration systems in wastewater treatment plants (WWTP) under process conditions can be monitored with off-gas tests. The ex situ off-gas method transfers activated sludge from an adjacent aeration tank into aerated columns to determine oxygen transfer parameters (e.g., the α-factor). This method is an alternative to in situ off-gas testing with hoods at the tank surface; however, its application and measurement uncertainty have not been examined yet. We outline our experience from long-term off-gas testing with two pilot-scale test reactors (8.3 m(3) volume). Global variance-based sensitivity analysis using Sobol’ indices revealed oxygen concentration in off-gas and dissolved oxygen as the most important input quantities to determine α-factors accurately. Measurement uncertainty of other instruments was negligible. These findings are transferable to in situ off-gas hoods because the methods are similar. Random measurement error of α-factors was estimated with uncertainty analysis and comparison measurements to a relative standard deviation of about ± 2.8% for our ex situ pilot setup. Diffuser fouling, biofilm growth, or sensor drift caused systematic errors avoidable by maintenance. Additional mixing of bubble column due to sludge inflow into ex situ tanks led to a systematic overestimation of α-factors at lower airflow rates. Hence, the ex situ off-gas method is not suitable to determine α-factors for the design of aeration systems but offers unique possibilities for research of oxygen transfer dynamics and development of aeration equipment because ex situ columns can be operated independently from a full-scale activated sludge tank. |
format | Online Article Text |
id | pubmed-9672027 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-96720272022-11-19 Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty Schwarz, Maximilian Trippel, Jana Engelhart, Markus Wagner, Martin Environ Sci Pollut Res Int Research Article Performance of aeration systems in wastewater treatment plants (WWTP) under process conditions can be monitored with off-gas tests. The ex situ off-gas method transfers activated sludge from an adjacent aeration tank into aerated columns to determine oxygen transfer parameters (e.g., the α-factor). This method is an alternative to in situ off-gas testing with hoods at the tank surface; however, its application and measurement uncertainty have not been examined yet. We outline our experience from long-term off-gas testing with two pilot-scale test reactors (8.3 m(3) volume). Global variance-based sensitivity analysis using Sobol’ indices revealed oxygen concentration in off-gas and dissolved oxygen as the most important input quantities to determine α-factors accurately. Measurement uncertainty of other instruments was negligible. These findings are transferable to in situ off-gas hoods because the methods are similar. Random measurement error of α-factors was estimated with uncertainty analysis and comparison measurements to a relative standard deviation of about ± 2.8% for our ex situ pilot setup. Diffuser fouling, biofilm growth, or sensor drift caused systematic errors avoidable by maintenance. Additional mixing of bubble column due to sludge inflow into ex situ tanks led to a systematic overestimation of α-factors at lower airflow rates. Hence, the ex situ off-gas method is not suitable to determine α-factors for the design of aeration systems but offers unique possibilities for research of oxygen transfer dynamics and development of aeration equipment because ex situ columns can be operated independently from a full-scale activated sludge tank. Springer Berlin Heidelberg 2022-07-12 2022 /pmc/articles/PMC9672027/ /pubmed/35829889 http://dx.doi.org/10.1007/s11356-022-21915-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Article Schwarz, Maximilian Trippel, Jana Engelhart, Markus Wagner, Martin Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty |
title | Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty |
title_full | Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty |
title_fullStr | Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty |
title_full_unstemmed | Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty |
title_short | Determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty |
title_sort | determination of alpha factors for monitoring of aeration systems with the ex situ off-gas method: experience from practical application and estimation of measurement uncertainty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9672027/ https://www.ncbi.nlm.nih.gov/pubmed/35829889 http://dx.doi.org/10.1007/s11356-022-21915-2 |
work_keys_str_mv | AT schwarzmaximilian determinationofalphafactorsformonitoringofaerationsystemswiththeexsituoffgasmethodexperiencefrompracticalapplicationandestimationofmeasurementuncertainty AT trippeljana determinationofalphafactorsformonitoringofaerationsystemswiththeexsituoffgasmethodexperiencefrompracticalapplicationandestimationofmeasurementuncertainty AT engelhartmarkus determinationofalphafactorsformonitoringofaerationsystemswiththeexsituoffgasmethodexperiencefrompracticalapplicationandestimationofmeasurementuncertainty AT wagnermartin determinationofalphafactorsformonitoringofaerationsystemswiththeexsituoffgasmethodexperiencefrompracticalapplicationandestimationofmeasurementuncertainty |