Cargando…
Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI
BACKGROUND AND PURPOSE: Motion mitigation is of crucial importance in particle therapy (PT) of patients with abdominal tumors to ensure high-precision irradiation. Magnetic resonance imaging (MRI) is an excellent modality for target volume delineation and motion estimation of mobile soft-tissue tumo...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9672128/ https://www.ncbi.nlm.nih.gov/pubmed/36407488 http://dx.doi.org/10.1016/j.ctro.2022.11.006 |
_version_ | 1784832692630585344 |
---|---|
author | Schneider, Sergej Stefanowicz, Sarah Jentsch, Christina Lohaus, Fabian Thiele, Julia Haak, Danilo Valentini, Chiara Platzek, Ivan G. C. Troost, Esther Hoffmann, Aswin L. |
author_facet | Schneider, Sergej Stefanowicz, Sarah Jentsch, Christina Lohaus, Fabian Thiele, Julia Haak, Danilo Valentini, Chiara Platzek, Ivan G. C. Troost, Esther Hoffmann, Aswin L. |
author_sort | Schneider, Sergej |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Motion mitigation is of crucial importance in particle therapy (PT) of patients with abdominal tumors to ensure high-precision irradiation. Magnetic resonance imaging (MRI) is an excellent modality for target volume delineation and motion estimation of mobile soft-tissue tumors. Thus, the aims of this study were to develop an MRI- and PT-compatible abdominal compression device, to investigate its effect on pancreas motion reduction, and to evaluate patient tolerability and acceptance. MATERIALS AND METHODS: In a prospective clinical study, 16 patients with abdominal tumors received an individualized polyethylene-based abdominal corset. Pancreas motion was analyzed using time- and phase resolved MRI scans (orthogonal 2D-cine and 4D MRI) with and without compression by the corset. The pancreas was manually segmented in each MRI data set and the population-averaged center-of-mass motion in inferior-superior (IS), anterior-posterior (AP) and left–right (LR) directions was determined. A questionnaire was developed to investigate the level of patient acceptance of the corset, which the patients completed after acquisition of the planning computed tomography (CT) and MRI scans. RESULTS: The corset was found to reduce pancreas motion predominantly in IS direction by on average 47 % − 51 % as found in the 2D-cine and 4D MRI data, respectively, while motion in the AP and LR direction was not significantly reduced. Most patients reported no discomfort when wearing the corset. CONCLUSION: An MRI- and PT-compatible individualized abdominal corset was presented, which substantially reduced breathing-induced pancreas motion and can be safely applied with no additional discomfort for the patients. The corset has been successfully integrated into our in-house clinical workflow for PT of tumors of the upper abdomen. |
format | Online Article Text |
id | pubmed-9672128 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-96721282022-11-19 Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI Schneider, Sergej Stefanowicz, Sarah Jentsch, Christina Lohaus, Fabian Thiele, Julia Haak, Danilo Valentini, Chiara Platzek, Ivan G. C. Troost, Esther Hoffmann, Aswin L. Clin Transl Radiat Oncol Article BACKGROUND AND PURPOSE: Motion mitigation is of crucial importance in particle therapy (PT) of patients with abdominal tumors to ensure high-precision irradiation. Magnetic resonance imaging (MRI) is an excellent modality for target volume delineation and motion estimation of mobile soft-tissue tumors. Thus, the aims of this study were to develop an MRI- and PT-compatible abdominal compression device, to investigate its effect on pancreas motion reduction, and to evaluate patient tolerability and acceptance. MATERIALS AND METHODS: In a prospective clinical study, 16 patients with abdominal tumors received an individualized polyethylene-based abdominal corset. Pancreas motion was analyzed using time- and phase resolved MRI scans (orthogonal 2D-cine and 4D MRI) with and without compression by the corset. The pancreas was manually segmented in each MRI data set and the population-averaged center-of-mass motion in inferior-superior (IS), anterior-posterior (AP) and left–right (LR) directions was determined. A questionnaire was developed to investigate the level of patient acceptance of the corset, which the patients completed after acquisition of the planning computed tomography (CT) and MRI scans. RESULTS: The corset was found to reduce pancreas motion predominantly in IS direction by on average 47 % − 51 % as found in the 2D-cine and 4D MRI data, respectively, while motion in the AP and LR direction was not significantly reduced. Most patients reported no discomfort when wearing the corset. CONCLUSION: An MRI- and PT-compatible individualized abdominal corset was presented, which substantially reduced breathing-induced pancreas motion and can be safely applied with no additional discomfort for the patients. The corset has been successfully integrated into our in-house clinical workflow for PT of tumors of the upper abdomen. Elsevier 2022-11-09 /pmc/articles/PMC9672128/ /pubmed/36407488 http://dx.doi.org/10.1016/j.ctro.2022.11.006 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Schneider, Sergej Stefanowicz, Sarah Jentsch, Christina Lohaus, Fabian Thiele, Julia Haak, Danilo Valentini, Chiara Platzek, Ivan G. C. Troost, Esther Hoffmann, Aswin L. Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI |
title | Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI |
title_full | Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI |
title_fullStr | Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI |
title_full_unstemmed | Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI |
title_short | Reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and MRI |
title_sort | reduction of intrafraction pancreas motion using an abdominal corset compatible with proton therapy and mri |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9672128/ https://www.ncbi.nlm.nih.gov/pubmed/36407488 http://dx.doi.org/10.1016/j.ctro.2022.11.006 |
work_keys_str_mv | AT schneidersergej reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT stefanowiczsarah reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT jentschchristina reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT lohausfabian reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT thielejulia reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT haakdanilo reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT valentinichiara reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT platzekivan reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT gctroostesther reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri AT hoffmannaswinl reductionofintrafractionpancreasmotionusinganabdominalcorsetcompatiblewithprotontherapyandmri |