Cargando…

Influence of aging on mechanical properties of the femoral neck using an inverse method

Today, we are facing rapid aging of the world population, which increases the incidence of hip fractures. The gold standard of bone strength assessment in the laboratory is micro-computed finite element analysis (μFEA) based on micro-computed tomography (μCT) images. In clinics, the standard method...

Descripción completa

Detalles Bibliográficos
Autores principales: Voumard, Benjamin, Stefanek, Pia, Pretterklieber, Michael, Pahr, Dieter, Zysset, Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9673104/
https://www.ncbi.nlm.nih.gov/pubmed/36407416
http://dx.doi.org/10.1016/j.bonr.2022.101638
_version_ 1784832879391408128
author Voumard, Benjamin
Stefanek, Pia
Pretterklieber, Michael
Pahr, Dieter
Zysset, Philippe
author_facet Voumard, Benjamin
Stefanek, Pia
Pretterklieber, Michael
Pahr, Dieter
Zysset, Philippe
author_sort Voumard, Benjamin
collection PubMed
description Today, we are facing rapid aging of the world population, which increases the incidence of hip fractures. The gold standard of bone strength assessment in the laboratory is micro-computed finite element analysis (μFEA) based on micro-computed tomography (μCT) images. In clinics, the standard method to assess bone fracture risk is based on areal bone mineral density (aBMD), measured by dual-energy X-ray absorptiometry (DXA). In addition, homogenized finite element analysis (hFEA) constructed from quantitative computed tomography reconstructions (QCT) predicts clinical bone strength more accurately than DXA. Despite considerable evidence of degradation of bone material properties with age, in the past fifty years of finite element analysis to predict bone strength, bone material parameters remained independent of age. This study aims to assess the influence of age on apparent modulus, yield stress, and strength predictions of the human femoral neck made by laboratory-available bone volume fraction (BV/TV) and μFEA; and by clinically available DXA and hFEA. Using an inverse method, we test the hypothesis that FEA material parameters are independent of age. Eighty-six human femora were scanned with DXA (aBMD) and with QCT. The femoral necks were extracted and scanned at 16 μm resolution with μCT. The grayscale images were downscaled to 32 μm and 65 μm for linear and non-linear analyses, respectively, and segmented. The μFE solver ParOSolNL (non-linear) and a standard hFEA method were applied to the neck sections with the same material properties for all samples to compute apparent modulus, yield stress, and strength. Laboratory-available BV/TV was a good predictor of apparent modulus (R(2) = 0.76), almost as good as μFEA (R(2) = 0.79). However, yield stress and strength were better predicted by μFEA (R(2) = 0.92, R(2) = 0.86, resp.) than BV/TV (R(2) = 0.76, R(2) = 0.76, resp.). For clinically available variables, prediction of apparent modulus was better with hFEA than aBMD (R(2) = 0.67, R(2) = 0.58, resp.). hFEA outperformed aBMD for predictions of yield stress (R(2) = 0.63 vs R(2) = 0.34 for female and R(2) = 0.55 for male) and strength (R(2) = 0.48 vs R(2) = 0.33 for female and R(2) = 0.15 for male). The inclusion of age did not improve the multiple linear models for apparent modulus, yield stress, and strength. The resolution of the μFE meshes seems to account for most morphological changes induced by aging. The errors between the simulation and the experiment for apparent modulus, yield stress, and strength were age-independent, suggesting no rationale for correcting tissue material parameters in the current FE analysis of the aging femoral neck.
format Online
Article
Text
id pubmed-9673104
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-96731042022-11-19 Influence of aging on mechanical properties of the femoral neck using an inverse method Voumard, Benjamin Stefanek, Pia Pretterklieber, Michael Pahr, Dieter Zysset, Philippe Bone Rep Corrigenda Today, we are facing rapid aging of the world population, which increases the incidence of hip fractures. The gold standard of bone strength assessment in the laboratory is micro-computed finite element analysis (μFEA) based on micro-computed tomography (μCT) images. In clinics, the standard method to assess bone fracture risk is based on areal bone mineral density (aBMD), measured by dual-energy X-ray absorptiometry (DXA). In addition, homogenized finite element analysis (hFEA) constructed from quantitative computed tomography reconstructions (QCT) predicts clinical bone strength more accurately than DXA. Despite considerable evidence of degradation of bone material properties with age, in the past fifty years of finite element analysis to predict bone strength, bone material parameters remained independent of age. This study aims to assess the influence of age on apparent modulus, yield stress, and strength predictions of the human femoral neck made by laboratory-available bone volume fraction (BV/TV) and μFEA; and by clinically available DXA and hFEA. Using an inverse method, we test the hypothesis that FEA material parameters are independent of age. Eighty-six human femora were scanned with DXA (aBMD) and with QCT. The femoral necks were extracted and scanned at 16 μm resolution with μCT. The grayscale images were downscaled to 32 μm and 65 μm for linear and non-linear analyses, respectively, and segmented. The μFE solver ParOSolNL (non-linear) and a standard hFEA method were applied to the neck sections with the same material properties for all samples to compute apparent modulus, yield stress, and strength. Laboratory-available BV/TV was a good predictor of apparent modulus (R(2) = 0.76), almost as good as μFEA (R(2) = 0.79). However, yield stress and strength were better predicted by μFEA (R(2) = 0.92, R(2) = 0.86, resp.) than BV/TV (R(2) = 0.76, R(2) = 0.76, resp.). For clinically available variables, prediction of apparent modulus was better with hFEA than aBMD (R(2) = 0.67, R(2) = 0.58, resp.). hFEA outperformed aBMD for predictions of yield stress (R(2) = 0.63 vs R(2) = 0.34 for female and R(2) = 0.55 for male) and strength (R(2) = 0.48 vs R(2) = 0.33 for female and R(2) = 0.15 for male). The inclusion of age did not improve the multiple linear models for apparent modulus, yield stress, and strength. The resolution of the μFE meshes seems to account for most morphological changes induced by aging. The errors between the simulation and the experiment for apparent modulus, yield stress, and strength were age-independent, suggesting no rationale for correcting tissue material parameters in the current FE analysis of the aging femoral neck. Elsevier 2022-11-14 /pmc/articles/PMC9673104/ /pubmed/36407416 http://dx.doi.org/10.1016/j.bonr.2022.101638 Text en © 2022 Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Corrigenda
Voumard, Benjamin
Stefanek, Pia
Pretterklieber, Michael
Pahr, Dieter
Zysset, Philippe
Influence of aging on mechanical properties of the femoral neck using an inverse method
title Influence of aging on mechanical properties of the femoral neck using an inverse method
title_full Influence of aging on mechanical properties of the femoral neck using an inverse method
title_fullStr Influence of aging on mechanical properties of the femoral neck using an inverse method
title_full_unstemmed Influence of aging on mechanical properties of the femoral neck using an inverse method
title_short Influence of aging on mechanical properties of the femoral neck using an inverse method
title_sort influence of aging on mechanical properties of the femoral neck using an inverse method
topic Corrigenda
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9673104/
https://www.ncbi.nlm.nih.gov/pubmed/36407416
http://dx.doi.org/10.1016/j.bonr.2022.101638
work_keys_str_mv AT voumardbenjamin influenceofagingonmechanicalpropertiesofthefemoralneckusinganinversemethod
AT stefanekpia influenceofagingonmechanicalpropertiesofthefemoralneckusinganinversemethod
AT pretterkliebermichael influenceofagingonmechanicalpropertiesofthefemoralneckusinganinversemethod
AT pahrdieter influenceofagingonmechanicalpropertiesofthefemoralneckusinganinversemethod
AT zyssetphilippe influenceofagingonmechanicalpropertiesofthefemoralneckusinganinversemethod