Cargando…

Geometry design for a fully insertable glucose biosensor with multimodal optical readout

SIGNIFICANCE: Insertable optical continuous glucose monitors (CGMs) with wearable readers are a strong option for monitoring individuals with diabetes. However, a fully insertable CGM requires a small form factor while still delivering sufficient signal to be read through tissue by an external devic...

Descripción completa

Detalles Bibliográficos
Autores principales: Fine, Jesse, Coté, Gerard L., McShane, Michael J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9673816/
https://www.ncbi.nlm.nih.gov/pubmed/36401344
http://dx.doi.org/10.1117/1.JBO.27.11.117001
_version_ 1784833028731699200
author Fine, Jesse
Coté, Gerard L.
McShane, Michael J.
author_facet Fine, Jesse
Coté, Gerard L.
McShane, Michael J.
author_sort Fine, Jesse
collection PubMed
description SIGNIFICANCE: Insertable optical continuous glucose monitors (CGMs) with wearable readers are a strong option for monitoring individuals with diabetes. However, a fully insertable CGM requires a small form factor while still delivering sufficient signal to be read through tissue by an external device. Previous work has suggested that a multimodal repeating unit (barcode) approach may meet these requirements, but the biosensor geometry must be optimized to meet performance criteria. AIM: This work details in silico trials conducted to evaluate the geometry of a fully insertable multimodal optical biosensor with respect to both optical output and species diffusion in vivo. APPROACH: Monte Carlo modeling is used to evaluate the luminescent output of three presupposed biosensor designs based on size constraints for an injectable and logical placement of the bar code compartments. Specifically, the sensitivity of the luminescent output to displacement of the biosensor in the [Formula: see text] and [Formula: see text] directions, overall size of the selected design, and size of an individual repeating unit are analyzed. Further, an experimentally validated multiphysics model is used to evaluate the diffusion and reaction of glucose and oxygen within the biosensor to estimate the occurrence of chemical crosstalk between the assay components. RESULTS: A stacked cylinder multimodal biosensor 4.4 mm in length with repeating units 0.36 mm in length was found to yield a greater luminescent output than the current “barcode” biosensor design. In addition, it was found that a biosensor with enzymatic elements does not significantly deplete glucose locally and thus does not impact the diffusion profile of glucose in adjacent compartments containing nonenzymatic assays. CONCLUSIONS: Computational modeling was used to design the geometry of a multimodal, insertable, and optical CGM to ensure that the optical output and chemical diffusion profile are sufficient for this device to function in vivo.
format Online
Article
Text
id pubmed-9673816
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-96738162022-11-21 Geometry design for a fully insertable glucose biosensor with multimodal optical readout Fine, Jesse Coté, Gerard L. McShane, Michael J. J Biomed Opt Sensing SIGNIFICANCE: Insertable optical continuous glucose monitors (CGMs) with wearable readers are a strong option for monitoring individuals with diabetes. However, a fully insertable CGM requires a small form factor while still delivering sufficient signal to be read through tissue by an external device. Previous work has suggested that a multimodal repeating unit (barcode) approach may meet these requirements, but the biosensor geometry must be optimized to meet performance criteria. AIM: This work details in silico trials conducted to evaluate the geometry of a fully insertable multimodal optical biosensor with respect to both optical output and species diffusion in vivo. APPROACH: Monte Carlo modeling is used to evaluate the luminescent output of three presupposed biosensor designs based on size constraints for an injectable and logical placement of the bar code compartments. Specifically, the sensitivity of the luminescent output to displacement of the biosensor in the [Formula: see text] and [Formula: see text] directions, overall size of the selected design, and size of an individual repeating unit are analyzed. Further, an experimentally validated multiphysics model is used to evaluate the diffusion and reaction of glucose and oxygen within the biosensor to estimate the occurrence of chemical crosstalk between the assay components. RESULTS: A stacked cylinder multimodal biosensor 4.4 mm in length with repeating units 0.36 mm in length was found to yield a greater luminescent output than the current “barcode” biosensor design. In addition, it was found that a biosensor with enzymatic elements does not significantly deplete glucose locally and thus does not impact the diffusion profile of glucose in adjacent compartments containing nonenzymatic assays. CONCLUSIONS: Computational modeling was used to design the geometry of a multimodal, insertable, and optical CGM to ensure that the optical output and chemical diffusion profile are sufficient for this device to function in vivo. Society of Photo-Optical Instrumentation Engineers 2022-11-18 2022-11 /pmc/articles/PMC9673816/ /pubmed/36401344 http://dx.doi.org/10.1117/1.JBO.27.11.117001 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Sensing
Fine, Jesse
Coté, Gerard L.
McShane, Michael J.
Geometry design for a fully insertable glucose biosensor with multimodal optical readout
title Geometry design for a fully insertable glucose biosensor with multimodal optical readout
title_full Geometry design for a fully insertable glucose biosensor with multimodal optical readout
title_fullStr Geometry design for a fully insertable glucose biosensor with multimodal optical readout
title_full_unstemmed Geometry design for a fully insertable glucose biosensor with multimodal optical readout
title_short Geometry design for a fully insertable glucose biosensor with multimodal optical readout
title_sort geometry design for a fully insertable glucose biosensor with multimodal optical readout
topic Sensing
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9673816/
https://www.ncbi.nlm.nih.gov/pubmed/36401344
http://dx.doi.org/10.1117/1.JBO.27.11.117001
work_keys_str_mv AT finejesse geometrydesignforafullyinsertableglucosebiosensorwithmultimodalopticalreadout
AT cotegerardl geometrydesignforafullyinsertableglucosebiosensorwithmultimodalopticalreadout
AT mcshanemichaelj geometrydesignforafullyinsertableglucosebiosensorwithmultimodalopticalreadout