Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease

OBJECTIVE: To investigate the application effect of 24 h dynamic electrocardiogram in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease. METHODS: A total of 206 elderly patients suspected of coronary heart disease (CHD) with asymptomati...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Zongwei, Tan, Hong, Liu, Xuemei, Tang, Minghua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674423/
https://www.ncbi.nlm.nih.gov/pubmed/36406933
http://dx.doi.org/10.1155/2022/3228023
_version_ 1784833149474177024
author Chen, Zongwei
Tan, Hong
Liu, Xuemei
Tang, Minghua
author_facet Chen, Zongwei
Tan, Hong
Liu, Xuemei
Tang, Minghua
author_sort Chen, Zongwei
collection PubMed
description OBJECTIVE: To investigate the application effect of 24 h dynamic electrocardiogram in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease. METHODS: A total of 206 elderly patients suspected of coronary heart disease (CHD) with asymptomatic myocardial ischemia and arrhythmia were selected as the research subjects. 24 h dynamic electrocardiogram and conventional electrocardiogram examinations were conducted. Coronary angiography was used as the gold standard to observe the performance of the two examination methods in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD. RESULTS: Coronary angiography showed 174 positive cases and 32 negative cases among the 206 patients. The diagnostic results of a conventional electrocardiogram showed 150 positive cases and 20 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 86.21%, 62.50%, 82.52%, 92.59%, and 45.45%, respectively. The diagnostic results of 24 h dynamic electrocardiograms showed 168 positive cases and 29 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 96.55%, 96.63%, 95.63%, 98.25%, and 82.86%, respectively. The above results indicated that 24 h dynamic electrocardiogram was significantly better (P < 0.05). The detection rate of arrhythmia types by 24-hour dynamic electrocardiogram was significantly higher than that of conventional electrocardiogram (P < 0.05). CONCLUSION: 24 h dynamic electrocardiogram is helpful for the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD and can improve the detection rate, thereby providing a basis for clinical diagnosis and treatment.
format Online
Article
Text
id pubmed-9674423
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-96744232022-11-19 Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease Chen, Zongwei Tan, Hong Liu, Xuemei Tang, Minghua Emerg Med Int Research Article OBJECTIVE: To investigate the application effect of 24 h dynamic electrocardiogram in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease. METHODS: A total of 206 elderly patients suspected of coronary heart disease (CHD) with asymptomatic myocardial ischemia and arrhythmia were selected as the research subjects. 24 h dynamic electrocardiogram and conventional electrocardiogram examinations were conducted. Coronary angiography was used as the gold standard to observe the performance of the two examination methods in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD. RESULTS: Coronary angiography showed 174 positive cases and 32 negative cases among the 206 patients. The diagnostic results of a conventional electrocardiogram showed 150 positive cases and 20 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 86.21%, 62.50%, 82.52%, 92.59%, and 45.45%, respectively. The diagnostic results of 24 h dynamic electrocardiograms showed 168 positive cases and 29 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 96.55%, 96.63%, 95.63%, 98.25%, and 82.86%, respectively. The above results indicated that 24 h dynamic electrocardiogram was significantly better (P < 0.05). The detection rate of arrhythmia types by 24-hour dynamic electrocardiogram was significantly higher than that of conventional electrocardiogram (P < 0.05). CONCLUSION: 24 h dynamic electrocardiogram is helpful for the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD and can improve the detection rate, thereby providing a basis for clinical diagnosis and treatment. Hindawi 2022-11-11 /pmc/articles/PMC9674423/ /pubmed/36406933 http://dx.doi.org/10.1155/2022/3228023 Text en Copyright © 2022 Zongwei Chen et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chen, Zongwei
Tan, Hong
Liu, Xuemei
Tang, Minghua
Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease
title Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease
title_full Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease
title_fullStr Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease
title_full_unstemmed Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease
title_short Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease
title_sort application of 24 h dynamic electrocardiography in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674423/
https://www.ncbi.nlm.nih.gov/pubmed/36406933
http://dx.doi.org/10.1155/2022/3228023
work_keys_str_mv AT chenzongwei applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease
AT tanhong applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease
AT liuxuemei applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease
AT tangminghua applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease