Cargando…
Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease
OBJECTIVE: To investigate the application effect of 24 h dynamic electrocardiogram in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease. METHODS: A total of 206 elderly patients suspected of coronary heart disease (CHD) with asymptomati...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674423/ https://www.ncbi.nlm.nih.gov/pubmed/36406933 http://dx.doi.org/10.1155/2022/3228023 |
_version_ | 1784833149474177024 |
---|---|
author | Chen, Zongwei Tan, Hong Liu, Xuemei Tang, Minghua |
author_facet | Chen, Zongwei Tan, Hong Liu, Xuemei Tang, Minghua |
author_sort | Chen, Zongwei |
collection | PubMed |
description | OBJECTIVE: To investigate the application effect of 24 h dynamic electrocardiogram in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease. METHODS: A total of 206 elderly patients suspected of coronary heart disease (CHD) with asymptomatic myocardial ischemia and arrhythmia were selected as the research subjects. 24 h dynamic electrocardiogram and conventional electrocardiogram examinations were conducted. Coronary angiography was used as the gold standard to observe the performance of the two examination methods in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD. RESULTS: Coronary angiography showed 174 positive cases and 32 negative cases among the 206 patients. The diagnostic results of a conventional electrocardiogram showed 150 positive cases and 20 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 86.21%, 62.50%, 82.52%, 92.59%, and 45.45%, respectively. The diagnostic results of 24 h dynamic electrocardiograms showed 168 positive cases and 29 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 96.55%, 96.63%, 95.63%, 98.25%, and 82.86%, respectively. The above results indicated that 24 h dynamic electrocardiogram was significantly better (P < 0.05). The detection rate of arrhythmia types by 24-hour dynamic electrocardiogram was significantly higher than that of conventional electrocardiogram (P < 0.05). CONCLUSION: 24 h dynamic electrocardiogram is helpful for the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD and can improve the detection rate, thereby providing a basis for clinical diagnosis and treatment. |
format | Online Article Text |
id | pubmed-9674423 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-96744232022-11-19 Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease Chen, Zongwei Tan, Hong Liu, Xuemei Tang, Minghua Emerg Med Int Research Article OBJECTIVE: To investigate the application effect of 24 h dynamic electrocardiogram in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease. METHODS: A total of 206 elderly patients suspected of coronary heart disease (CHD) with asymptomatic myocardial ischemia and arrhythmia were selected as the research subjects. 24 h dynamic electrocardiogram and conventional electrocardiogram examinations were conducted. Coronary angiography was used as the gold standard to observe the performance of the two examination methods in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD. RESULTS: Coronary angiography showed 174 positive cases and 32 negative cases among the 206 patients. The diagnostic results of a conventional electrocardiogram showed 150 positive cases and 20 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 86.21%, 62.50%, 82.52%, 92.59%, and 45.45%, respectively. The diagnostic results of 24 h dynamic electrocardiograms showed 168 positive cases and 29 negative cases. Its sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 96.55%, 96.63%, 95.63%, 98.25%, and 82.86%, respectively. The above results indicated that 24 h dynamic electrocardiogram was significantly better (P < 0.05). The detection rate of arrhythmia types by 24-hour dynamic electrocardiogram was significantly higher than that of conventional electrocardiogram (P < 0.05). CONCLUSION: 24 h dynamic electrocardiogram is helpful for the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with CHD and can improve the detection rate, thereby providing a basis for clinical diagnosis and treatment. Hindawi 2022-11-11 /pmc/articles/PMC9674423/ /pubmed/36406933 http://dx.doi.org/10.1155/2022/3228023 Text en Copyright © 2022 Zongwei Chen et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Chen, Zongwei Tan, Hong Liu, Xuemei Tang, Minghua Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease |
title | Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease |
title_full | Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease |
title_fullStr | Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease |
title_full_unstemmed | Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease |
title_short | Application of 24 h Dynamic Electrocardiography in the Diagnosis of Asymptomatic Myocardial Ischemia with Arrhythmia in Elderly Patients with Coronary Heart Disease |
title_sort | application of 24 h dynamic electrocardiography in the diagnosis of asymptomatic myocardial ischemia with arrhythmia in elderly patients with coronary heart disease |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674423/ https://www.ncbi.nlm.nih.gov/pubmed/36406933 http://dx.doi.org/10.1155/2022/3228023 |
work_keys_str_mv | AT chenzongwei applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease AT tanhong applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease AT liuxuemei applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease AT tangminghua applicationof24hdynamicelectrocardiographyinthediagnosisofasymptomaticmyocardialischemiawitharrhythmiainelderlypatientswithcoronaryheartdisease |