Cargando…
The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
BACKGROUND AND PURPOSE: Metallic implants cause artefacts in computed tomography (CT) images and can introduce significant errors to structure visualisation and dosimetric calculation within the radiotherapy planning process. This study evaluated an orthopaedic metal artefact reduction algorithm and...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674537/ https://www.ncbi.nlm.nih.gov/pubmed/36411857 http://dx.doi.org/10.1016/j.phro.2022.11.007 |
_version_ | 1784833176407900160 |
---|---|
author | King, John Whittam, Shona Smith, David Al-Qaisieh, Bashar |
author_facet | King, John Whittam, Shona Smith, David Al-Qaisieh, Bashar |
author_sort | King, John |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Metallic implants cause artefacts in computed tomography (CT) images and can introduce significant errors to structure visualisation and dosimetric calculation within the radiotherapy planning process. This study evaluated an orthopaedic metal artefact reduction algorithm and its effect on the CT number, image noise, structure delineation, and treatment dose. METHODS: Raw CT data were reconstructed using standard filtered back projection and an artefact reduction algorithm to create ‘standard’ and ‘corrected’ images. A phantom containing tissue-mimicking inserts and two titanium plugs was imaged. The average CT number was compared to baseline data acquired without metal inserts. Data from 11 pelvic external beam radiotherapy (EBRT) patients with bi- or uni-lateral hip implants were retrospectively analysed. The clinically used treatment plans were re-computed on the corrected images. A prostate-mimicking phantom containing metal ‘implants’ was imaged, and 11 observers contoured both reconstructions. RESULTS: The artefact reduction algorithm improved the CT number in those areas most affected by metal artefacts and decreased noise by 19 % (P =.04) Changes in dose distributions on corrected images compared to those calculated using the current clinical protocol were clinically insignificant. Volumes contoured on the corrected phantom images had larger Dice coefficients than those contoured on the standard images (P =.001), as well as a 36 % lower standard deviation in volumes. CONCLUSION: This study demonstrates that the metal artefact reduction software reduces the error in CT numbers, can improve delineation accuracy, and can reduce inter-observer variability. It has the potential to streamline the planning pathway and improve treatment planning accuracy. |
format | Online Article Text |
id | pubmed-9674537 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-96745372022-11-20 The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis King, John Whittam, Shona Smith, David Al-Qaisieh, Bashar Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Metallic implants cause artefacts in computed tomography (CT) images and can introduce significant errors to structure visualisation and dosimetric calculation within the radiotherapy planning process. This study evaluated an orthopaedic metal artefact reduction algorithm and its effect on the CT number, image noise, structure delineation, and treatment dose. METHODS: Raw CT data were reconstructed using standard filtered back projection and an artefact reduction algorithm to create ‘standard’ and ‘corrected’ images. A phantom containing tissue-mimicking inserts and two titanium plugs was imaged. The average CT number was compared to baseline data acquired without metal inserts. Data from 11 pelvic external beam radiotherapy (EBRT) patients with bi- or uni-lateral hip implants were retrospectively analysed. The clinically used treatment plans were re-computed on the corrected images. A prostate-mimicking phantom containing metal ‘implants’ was imaged, and 11 observers contoured both reconstructions. RESULTS: The artefact reduction algorithm improved the CT number in those areas most affected by metal artefacts and decreased noise by 19 % (P =.04) Changes in dose distributions on corrected images compared to those calculated using the current clinical protocol were clinically insignificant. Volumes contoured on the corrected phantom images had larger Dice coefficients than those contoured on the standard images (P =.001), as well as a 36 % lower standard deviation in volumes. CONCLUSION: This study demonstrates that the metal artefact reduction software reduces the error in CT numbers, can improve delineation accuracy, and can reduce inter-observer variability. It has the potential to streamline the planning pathway and improve treatment planning accuracy. Elsevier 2022-11-12 /pmc/articles/PMC9674537/ /pubmed/36411857 http://dx.doi.org/10.1016/j.phro.2022.11.007 Text en Crown Copyright © 2022 Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article King, John Whittam, Shona Smith, David Al-Qaisieh, Bashar The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis |
title | The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis |
title_full | The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis |
title_fullStr | The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis |
title_full_unstemmed | The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis |
title_short | The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis |
title_sort | impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674537/ https://www.ncbi.nlm.nih.gov/pubmed/36411857 http://dx.doi.org/10.1016/j.phro.2022.11.007 |
work_keys_str_mv | AT kingjohn theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis AT whittamshona theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis AT smithdavid theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis AT alqaisiehbashar theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis AT kingjohn impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis AT whittamshona impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis AT smithdavid impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis AT alqaisiehbashar impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis |