The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis

BACKGROUND AND PURPOSE: Metallic implants cause artefacts in computed tomography (CT) images and can introduce significant errors to structure visualisation and dosimetric calculation within the radiotherapy planning process. This study evaluated an orthopaedic metal artefact reduction algorithm and...

Descripción completa

Detalles Bibliográficos
Autores principales: King, John, Whittam, Shona, Smith, David, Al-Qaisieh, Bashar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674537/
https://www.ncbi.nlm.nih.gov/pubmed/36411857
http://dx.doi.org/10.1016/j.phro.2022.11.007
_version_ 1784833176407900160
author King, John
Whittam, Shona
Smith, David
Al-Qaisieh, Bashar
author_facet King, John
Whittam, Shona
Smith, David
Al-Qaisieh, Bashar
author_sort King, John
collection PubMed
description BACKGROUND AND PURPOSE: Metallic implants cause artefacts in computed tomography (CT) images and can introduce significant errors to structure visualisation and dosimetric calculation within the radiotherapy planning process. This study evaluated an orthopaedic metal artefact reduction algorithm and its effect on the CT number, image noise, structure delineation, and treatment dose. METHODS: Raw CT data were reconstructed using standard filtered back projection and an artefact reduction algorithm to create ‘standard’ and ‘corrected’ images. A phantom containing tissue-mimicking inserts and two titanium plugs was imaged. The average CT number was compared to baseline data acquired without metal inserts. Data from 11 pelvic external beam radiotherapy (EBRT) patients with bi- or uni-lateral hip implants were retrospectively analysed. The clinically used treatment plans were re-computed on the corrected images. A prostate-mimicking phantom containing metal ‘implants’ was imaged, and 11 observers contoured both reconstructions. RESULTS: The artefact reduction algorithm improved the CT number in those areas most affected by metal artefacts and decreased noise by 19 % (P =.04) Changes in dose distributions on corrected images compared to those calculated using the current clinical protocol were clinically insignificant. Volumes contoured on the corrected phantom images had larger Dice coefficients than those contoured on the standard images (P =.001), as well as a 36 % lower standard deviation in volumes. CONCLUSION: This study demonstrates that the metal artefact reduction software reduces the error in CT numbers, can improve delineation accuracy, and can reduce inter-observer variability. It has the potential to streamline the planning pathway and improve treatment planning accuracy.
format Online
Article
Text
id pubmed-9674537
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-96745372022-11-20 The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis King, John Whittam, Shona Smith, David Al-Qaisieh, Bashar Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Metallic implants cause artefacts in computed tomography (CT) images and can introduce significant errors to structure visualisation and dosimetric calculation within the radiotherapy planning process. This study evaluated an orthopaedic metal artefact reduction algorithm and its effect on the CT number, image noise, structure delineation, and treatment dose. METHODS: Raw CT data were reconstructed using standard filtered back projection and an artefact reduction algorithm to create ‘standard’ and ‘corrected’ images. A phantom containing tissue-mimicking inserts and two titanium plugs was imaged. The average CT number was compared to baseline data acquired without metal inserts. Data from 11 pelvic external beam radiotherapy (EBRT) patients with bi- or uni-lateral hip implants were retrospectively analysed. The clinically used treatment plans were re-computed on the corrected images. A prostate-mimicking phantom containing metal ‘implants’ was imaged, and 11 observers contoured both reconstructions. RESULTS: The artefact reduction algorithm improved the CT number in those areas most affected by metal artefacts and decreased noise by 19 % (P =.04) Changes in dose distributions on corrected images compared to those calculated using the current clinical protocol were clinically insignificant. Volumes contoured on the corrected phantom images had larger Dice coefficients than those contoured on the standard images (P =.001), as well as a 36 % lower standard deviation in volumes. CONCLUSION: This study demonstrates that the metal artefact reduction software reduces the error in CT numbers, can improve delineation accuracy, and can reduce inter-observer variability. It has the potential to streamline the planning pathway and improve treatment planning accuracy. Elsevier 2022-11-12 /pmc/articles/PMC9674537/ /pubmed/36411857 http://dx.doi.org/10.1016/j.phro.2022.11.007 Text en Crown Copyright © 2022 Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
King, John
Whittam, Shona
Smith, David
Al-Qaisieh, Bashar
The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
title The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
title_full The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
title_fullStr The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
title_full_unstemmed The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
title_short The impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
title_sort impact of a metal artefact reduction algorithm on treatment planning for patients undergoing radiotherapy of the pelvis
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674537/
https://www.ncbi.nlm.nih.gov/pubmed/36411857
http://dx.doi.org/10.1016/j.phro.2022.11.007
work_keys_str_mv AT kingjohn theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis
AT whittamshona theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis
AT smithdavid theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis
AT alqaisiehbashar theimpactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis
AT kingjohn impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis
AT whittamshona impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis
AT smithdavid impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis
AT alqaisiehbashar impactofametalartefactreductionalgorithmontreatmentplanningforpatientsundergoingradiotherapyofthepelvis