Cargando…

Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence

In case of potential contamination, implantation of synthetic meshes in hernia and abdominal wall surgery is problematic due to a higher risk of mesh infection. As an alternative, a variety of different biologic meshes have been used. However, relevant data comparing outcome after implantation of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Goetz, Markus, Jurczyk, Maria, Junger, Henrik, Schlitt, Hans J., Brunner, Stefan M., Brennfleck, Frank W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674721/
https://www.ncbi.nlm.nih.gov/pubmed/36223064
http://dx.doi.org/10.1007/s13304-022-01378-3
_version_ 1784833212743155712
author Goetz, Markus
Jurczyk, Maria
Junger, Henrik
Schlitt, Hans J.
Brunner, Stefan M.
Brennfleck, Frank W.
author_facet Goetz, Markus
Jurczyk, Maria
Junger, Henrik
Schlitt, Hans J.
Brunner, Stefan M.
Brennfleck, Frank W.
author_sort Goetz, Markus
collection PubMed
description In case of potential contamination, implantation of synthetic meshes in hernia and abdominal wall surgery is problematic due to a higher risk of mesh infection. As an alternative, a variety of different biologic meshes have been used. However, relevant data comparing outcome after implantation of these meshes are lacking. Between January 2012 and October 2021, biologic meshes were used for reconstruction of the abdominal wall in 71 patients with preoperative or intraoperative abdominal contamination. In this retrospective study, semiresorbable biologic hybrid meshes (BHM) and completely resorbable meshes (CRM) were compared and analyzed using a Castor EDC database. In 28 patients, semiresorbable biologic hybrid meshes were used; in 43 patients, completely resorbable meshes were used. Both groups showed no difference in age, gender, BMI, operation duration, hernia size and Charlson comorbidity index. The risk degree of surgical-site occurrences was graded according to the Ventral Hernia Working Group (VHWG) classification, and the median value was 3 (range 2–4) in the BHM group and 3 (range 2–4) in the CRM group. Hernia recurrence within 24 months after hernia repair was significantly lower in the BHM group (3.6% vs. 28.9%; p = 0.03), while postoperative complication rate, with respect to seromas in need of therapy (61.4% vs. 55.5%, p = 0.43) and operative revision (28.6% vs. 16.3%, p = 0.22) was not different in either group. Biologic hybrid meshes can be used safely in case of possible contamination. BHM seems to reduce the risk of hernia recurrence compared to completely resorbable biologic meshes, but this has to be investigated further.
format Online
Article
Text
id pubmed-9674721
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-96747212022-11-20 Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence Goetz, Markus Jurczyk, Maria Junger, Henrik Schlitt, Hans J. Brunner, Stefan M. Brennfleck, Frank W. Updates Surg Original Article In case of potential contamination, implantation of synthetic meshes in hernia and abdominal wall surgery is problematic due to a higher risk of mesh infection. As an alternative, a variety of different biologic meshes have been used. However, relevant data comparing outcome after implantation of these meshes are lacking. Between January 2012 and October 2021, biologic meshes were used for reconstruction of the abdominal wall in 71 patients with preoperative or intraoperative abdominal contamination. In this retrospective study, semiresorbable biologic hybrid meshes (BHM) and completely resorbable meshes (CRM) were compared and analyzed using a Castor EDC database. In 28 patients, semiresorbable biologic hybrid meshes were used; in 43 patients, completely resorbable meshes were used. Both groups showed no difference in age, gender, BMI, operation duration, hernia size and Charlson comorbidity index. The risk degree of surgical-site occurrences was graded according to the Ventral Hernia Working Group (VHWG) classification, and the median value was 3 (range 2–4) in the BHM group and 3 (range 2–4) in the CRM group. Hernia recurrence within 24 months after hernia repair was significantly lower in the BHM group (3.6% vs. 28.9%; p = 0.03), while postoperative complication rate, with respect to seromas in need of therapy (61.4% vs. 55.5%, p = 0.43) and operative revision (28.6% vs. 16.3%, p = 0.22) was not different in either group. Biologic hybrid meshes can be used safely in case of possible contamination. BHM seems to reduce the risk of hernia recurrence compared to completely resorbable biologic meshes, but this has to be investigated further. Springer International Publishing 2022-10-12 2022 /pmc/articles/PMC9674721/ /pubmed/36223064 http://dx.doi.org/10.1007/s13304-022-01378-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Goetz, Markus
Jurczyk, Maria
Junger, Henrik
Schlitt, Hans J.
Brunner, Stefan M.
Brennfleck, Frank W.
Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence
title Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence
title_full Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence
title_fullStr Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence
title_full_unstemmed Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence
title_short Semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence
title_sort semiresorbable biologic hybrid meshes for ventral abdominal hernia repair in potentially contaminated settings: lower risk of recurrence
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674721/
https://www.ncbi.nlm.nih.gov/pubmed/36223064
http://dx.doi.org/10.1007/s13304-022-01378-3
work_keys_str_mv AT goetzmarkus semiresorbablebiologichybridmeshesforventralabdominalherniarepairinpotentiallycontaminatedsettingslowerriskofrecurrence
AT jurczykmaria semiresorbablebiologichybridmeshesforventralabdominalherniarepairinpotentiallycontaminatedsettingslowerriskofrecurrence
AT jungerhenrik semiresorbablebiologichybridmeshesforventralabdominalherniarepairinpotentiallycontaminatedsettingslowerriskofrecurrence
AT schlitthansj semiresorbablebiologichybridmeshesforventralabdominalherniarepairinpotentiallycontaminatedsettingslowerriskofrecurrence
AT brunnerstefanm semiresorbablebiologichybridmeshesforventralabdominalherniarepairinpotentiallycontaminatedsettingslowerriskofrecurrence
AT brennfleckfrankw semiresorbablebiologichybridmeshesforventralabdominalherniarepairinpotentiallycontaminatedsettingslowerriskofrecurrence