Cargando…
Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup?
PURPOSE: We hypothesized that the intra-operative measurement of the femoral head may increase the accuracy of the acetabular cup size optimal selection in total hip arthroplasty (THA). The purpose of this clinical research was to analyze the correlation between the estimated cup size from intra-ope...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674749/ https://www.ncbi.nlm.nih.gov/pubmed/35951099 http://dx.doi.org/10.1007/s00264-022-05526-7 |
_version_ | 1784833218627764224 |
---|---|
author | Muñoz-Mahamud, Ernesto Chimeno, Clara Tornero, Eduard Alías, Alfonso Fernández-Valencia, Jenaro Ángel Combalia, Andrés |
author_facet | Muñoz-Mahamud, Ernesto Chimeno, Clara Tornero, Eduard Alías, Alfonso Fernández-Valencia, Jenaro Ángel Combalia, Andrés |
author_sort | Muñoz-Mahamud, Ernesto |
collection | PubMed |
description | PURPOSE: We hypothesized that the intra-operative measurement of the femoral head may increase the accuracy of the acetabular cup size optimal selection in total hip arthroplasty (THA). The purpose of this clinical research was to analyze the correlation between the estimated cup size from intra-operative measurement of the femoral head and the pre-operative templated cup size. METHODS: A prospective observational single-center study was conducted from June 2019 to January 2020 including primary THA (n = 100). All cases were pre-operatively templated. The measurement of the anterior–posterior diameter of the femoral head was routinely intra-operatively performed. Any definitive implanted cup was considered as “oversized” when the size was > 4 mm than the diameter of the native head. RESULTS: The median (interquartile range) size of the implanted cup, pre-operative planned cup size, and diameter of the femoral head were measured 52 (50–54) mm, 50 (48–54) mm and 49 (45–51) mm, respectively. Pre-operative planned size cup accurately predicted the implanted cup or differed in only one size (2 mm) in 77 (78%) cases. Otherwise, intra-operative femoral head measurement method accurately predicted the implanted or differed in only one size (2 mm) in 51 (87%) cases (p = 0.097). CONCLUSION: The intra-operative femoral head measurement is a simple and reliable tool to help the surgeons choose the best size of the acetabular cup and is as reliable as the pre-operative templating in order to avoid cup oversizing in THA. Utmost caution is warranted whenever the cup reamer is > 4 mm than the anterior–posterior diameter of the native head. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00264-022-05526-7. |
format | Online Article Text |
id | pubmed-9674749 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-96747492022-11-20 Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? Muñoz-Mahamud, Ernesto Chimeno, Clara Tornero, Eduard Alías, Alfonso Fernández-Valencia, Jenaro Ángel Combalia, Andrés Int Orthop Original Paper PURPOSE: We hypothesized that the intra-operative measurement of the femoral head may increase the accuracy of the acetabular cup size optimal selection in total hip arthroplasty (THA). The purpose of this clinical research was to analyze the correlation between the estimated cup size from intra-operative measurement of the femoral head and the pre-operative templated cup size. METHODS: A prospective observational single-center study was conducted from June 2019 to January 2020 including primary THA (n = 100). All cases were pre-operatively templated. The measurement of the anterior–posterior diameter of the femoral head was routinely intra-operatively performed. Any definitive implanted cup was considered as “oversized” when the size was > 4 mm than the diameter of the native head. RESULTS: The median (interquartile range) size of the implanted cup, pre-operative planned cup size, and diameter of the femoral head were measured 52 (50–54) mm, 50 (48–54) mm and 49 (45–51) mm, respectively. Pre-operative planned size cup accurately predicted the implanted cup or differed in only one size (2 mm) in 77 (78%) cases. Otherwise, intra-operative femoral head measurement method accurately predicted the implanted or differed in only one size (2 mm) in 51 (87%) cases (p = 0.097). CONCLUSION: The intra-operative femoral head measurement is a simple and reliable tool to help the surgeons choose the best size of the acetabular cup and is as reliable as the pre-operative templating in order to avoid cup oversizing in THA. Utmost caution is warranted whenever the cup reamer is > 4 mm than the anterior–posterior diameter of the native head. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00264-022-05526-7. Springer Berlin Heidelberg 2022-08-11 2022-12 /pmc/articles/PMC9674749/ /pubmed/35951099 http://dx.doi.org/10.1007/s00264-022-05526-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Muñoz-Mahamud, Ernesto Chimeno, Clara Tornero, Eduard Alías, Alfonso Fernández-Valencia, Jenaro Ángel Combalia, Andrés Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? |
title | Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? |
title_full | Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? |
title_fullStr | Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? |
title_full_unstemmed | Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? |
title_short | Can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? |
title_sort | can the intra-operative measurement of the diameter of the femoral head help surgeons to choose the best size of the acetabular cup? |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674749/ https://www.ncbi.nlm.nih.gov/pubmed/35951099 http://dx.doi.org/10.1007/s00264-022-05526-7 |
work_keys_str_mv | AT munozmahamudernesto cantheintraoperativemeasurementofthediameterofthefemoralheadhelpsurgeonstochoosethebestsizeoftheacetabularcup AT chimenoclara cantheintraoperativemeasurementofthediameterofthefemoralheadhelpsurgeonstochoosethebestsizeoftheacetabularcup AT torneroeduard cantheintraoperativemeasurementofthediameterofthefemoralheadhelpsurgeonstochoosethebestsizeoftheacetabularcup AT aliasalfonso cantheintraoperativemeasurementofthediameterofthefemoralheadhelpsurgeonstochoosethebestsizeoftheacetabularcup AT fernandezvalenciajenaroangel cantheintraoperativemeasurementofthediameterofthefemoralheadhelpsurgeonstochoosethebestsizeoftheacetabularcup AT combaliaandres cantheintraoperativemeasurementofthediameterofthefemoralheadhelpsurgeonstochoosethebestsizeoftheacetabularcup |