Cargando…
Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I
Cardiac troponin I (cTnI) is a specific cardiac biomarker for diagnosis of acute myocardial infarction (AMI). A sensitive and simple point-of-care test (POCT) is still required for early detection of AMI. To address this need, we developed a dip strip assay based on sandwich immunoassay coupled with...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674838/ https://www.ncbi.nlm.nih.gov/pubmed/36400826 http://dx.doi.org/10.1038/s41598-022-24458-1 |
_version_ | 1784833236837335040 |
---|---|
author | Poosinuntakul, Napakporn Chanmee, Theerawut Porntadavity, Sureerut Chailapakul, Orawon Apilux, Amara |
author_facet | Poosinuntakul, Napakporn Chanmee, Theerawut Porntadavity, Sureerut Chailapakul, Orawon Apilux, Amara |
author_sort | Poosinuntakul, Napakporn |
collection | PubMed |
description | Cardiac troponin I (cTnI) is a specific cardiac biomarker for diagnosis of acute myocardial infarction (AMI). A sensitive and simple point-of-care test (POCT) is still required for early detection of AMI. To address this need, we developed a dip strip assay based on sandwich immunoassay coupled with a silver enhancement system. Pre-incubation and silver enhancement were introduced to the dip strip to increase sensitivity. Due to the catalytic reaction of the silver enhancement solution, the red color of AuNPs changed to dark brown as silver ions precipitated and enlarged the AuNPs. The obtained results were easily seen by the naked eye. For quantitative analysis, the color intensity of the results was analyzed using a smartphone with RGB color picker application. The effects of operating parameters (volume of AuNP-Ab conjugate, volume of sample, incubation time, and analysis time) were investigated and optimized. Under optimal conditions, the limit of detection (LOD) by the naked eye was 0.5 ng/mL. The LOD with silver enhancement was 50-fold lower than without. For quantitative analysis using the smartphone, linearity of detection was observed through the range of 0.5–50 ng/mL (R(2) = 0.9952) and the LOD was 0.12 ng/mL. The developed method was successfully applied to detection of cTnI in serum samples, achieving analytical recoveries and %RSD in the ranges of 96.10–119.17% and 2.91–5.13%, respectively. Additionally, this developed assay was not cross reactive with the potentially interfering serum proteins. These results showed the great potential of this dip strip assay as an alternative POCT for detection of serum cTnI. |
format | Online Article Text |
id | pubmed-9674838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-96748382022-11-20 Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I Poosinuntakul, Napakporn Chanmee, Theerawut Porntadavity, Sureerut Chailapakul, Orawon Apilux, Amara Sci Rep Article Cardiac troponin I (cTnI) is a specific cardiac biomarker for diagnosis of acute myocardial infarction (AMI). A sensitive and simple point-of-care test (POCT) is still required for early detection of AMI. To address this need, we developed a dip strip assay based on sandwich immunoassay coupled with a silver enhancement system. Pre-incubation and silver enhancement were introduced to the dip strip to increase sensitivity. Due to the catalytic reaction of the silver enhancement solution, the red color of AuNPs changed to dark brown as silver ions precipitated and enlarged the AuNPs. The obtained results were easily seen by the naked eye. For quantitative analysis, the color intensity of the results was analyzed using a smartphone with RGB color picker application. The effects of operating parameters (volume of AuNP-Ab conjugate, volume of sample, incubation time, and analysis time) were investigated and optimized. Under optimal conditions, the limit of detection (LOD) by the naked eye was 0.5 ng/mL. The LOD with silver enhancement was 50-fold lower than without. For quantitative analysis using the smartphone, linearity of detection was observed through the range of 0.5–50 ng/mL (R(2) = 0.9952) and the LOD was 0.12 ng/mL. The developed method was successfully applied to detection of cTnI in serum samples, achieving analytical recoveries and %RSD in the ranges of 96.10–119.17% and 2.91–5.13%, respectively. Additionally, this developed assay was not cross reactive with the potentially interfering serum proteins. These results showed the great potential of this dip strip assay as an alternative POCT for detection of serum cTnI. Nature Publishing Group UK 2022-11-18 /pmc/articles/PMC9674838/ /pubmed/36400826 http://dx.doi.org/10.1038/s41598-022-24458-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Poosinuntakul, Napakporn Chanmee, Theerawut Porntadavity, Sureerut Chailapakul, Orawon Apilux, Amara Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I |
title | Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I |
title_full | Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I |
title_fullStr | Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I |
title_full_unstemmed | Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I |
title_short | Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I |
title_sort | silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin i |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674838/ https://www.ncbi.nlm.nih.gov/pubmed/36400826 http://dx.doi.org/10.1038/s41598-022-24458-1 |
work_keys_str_mv | AT poosinuntakulnapakporn silverenhancedcolloidalgolddipstripimmunoassayintegratedwithsmartphonebasedcolorimetryforsensitivedetectionofcardiacmarkertroponini AT chanmeetheerawut silverenhancedcolloidalgolddipstripimmunoassayintegratedwithsmartphonebasedcolorimetryforsensitivedetectionofcardiacmarkertroponini AT porntadavitysureerut silverenhancedcolloidalgolddipstripimmunoassayintegratedwithsmartphonebasedcolorimetryforsensitivedetectionofcardiacmarkertroponini AT chailapakulorawon silverenhancedcolloidalgolddipstripimmunoassayintegratedwithsmartphonebasedcolorimetryforsensitivedetectionofcardiacmarkertroponini AT apiluxamara silverenhancedcolloidalgolddipstripimmunoassayintegratedwithsmartphonebasedcolorimetryforsensitivedetectionofcardiacmarkertroponini |