Cargando…

An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement

INTRODUCTION: South Africa's significant burden of trauma and respiratory disease requires the regular need for intercostal drain (ICD) insertion. ICD misplacement is associated with significant complications. The aim of this study was to assess ICD insertion site accuracy and the factors affec...

Descripción completa

Detalles Bibliográficos
Autores principales: Korda, Tessa, Baillie-Stanton, Tammy, Goldstein, Lara Nicole
Formato: Online Artículo Texto
Lenguaje:English
Publicado: African Federation for Emergency Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674875/
https://www.ncbi.nlm.nih.gov/pubmed/36415447
http://dx.doi.org/10.1016/j.afjem.2022.10.011
_version_ 1784833244316827648
author Korda, Tessa
Baillie-Stanton, Tammy
Goldstein, Lara Nicole
author_facet Korda, Tessa
Baillie-Stanton, Tammy
Goldstein, Lara Nicole
author_sort Korda, Tessa
collection PubMed
description INTRODUCTION: South Africa's significant burden of trauma and respiratory disease requires the regular need for intercostal drain (ICD) insertion. ICD misplacement is associated with significant complications. The aim of this study was to assess ICD insertion site accuracy and the factors affecting accuracy by Emergency Department doctors. METHODS: This was a prospective, observational simulation-based study. Prior to participant admission, pertinent thoracic structures were marked on two simulated patients using an invisible marker which could only be seen using ultraviolet light. One by one, study participants were then asked to place a sticker on each side of each patient's chest to indicate where they would insert an ICD. Sticker placements were photographed under ultraviolet light. Placement sites were compared according to the most appropriate and accurate position for insertion (within the area superior to the 6(th) rib, posterior to pectoralis major and 1cm anterior to the mid-axillary line) as well as the British Thoracic Society's ‘triangle of safety’. Comparisons of accuracy were made between participant rank (junior vs senior doctor), participant experience, simulated patient BMI category and placement side. RESULTS: Insertion site was accurate in 47% of placements and within the ‘triangle of safety’ in 51% of placements. Improved accuracy was associated with greater participant experience (61% vs. 37%, p<0.01), and left-sided chest placement (54% vs 40%, p = 0.02). No difference was found when comparing simulated patient BMI category (low vs high, 43% vs 51%, p=0.18) or participant rank (junior vs senior, 41% vs 51%, p=0.10). CONCLUSION: Overall accuracy of ICD insertion site was low, and appropriate accuracy was only associated with greater participant experience and left sided placement. Further studies to determine methods to improve ICD placement accuracy are needed.
format Online
Article
Text
id pubmed-9674875
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher African Federation for Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-96748752022-11-21 An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement Korda, Tessa Baillie-Stanton, Tammy Goldstein, Lara Nicole Afr J Emerg Med Original Article INTRODUCTION: South Africa's significant burden of trauma and respiratory disease requires the regular need for intercostal drain (ICD) insertion. ICD misplacement is associated with significant complications. The aim of this study was to assess ICD insertion site accuracy and the factors affecting accuracy by Emergency Department doctors. METHODS: This was a prospective, observational simulation-based study. Prior to participant admission, pertinent thoracic structures were marked on two simulated patients using an invisible marker which could only be seen using ultraviolet light. One by one, study participants were then asked to place a sticker on each side of each patient's chest to indicate where they would insert an ICD. Sticker placements were photographed under ultraviolet light. Placement sites were compared according to the most appropriate and accurate position for insertion (within the area superior to the 6(th) rib, posterior to pectoralis major and 1cm anterior to the mid-axillary line) as well as the British Thoracic Society's ‘triangle of safety’. Comparisons of accuracy were made between participant rank (junior vs senior doctor), participant experience, simulated patient BMI category and placement side. RESULTS: Insertion site was accurate in 47% of placements and within the ‘triangle of safety’ in 51% of placements. Improved accuracy was associated with greater participant experience (61% vs. 37%, p<0.01), and left-sided chest placement (54% vs 40%, p = 0.02). No difference was found when comparing simulated patient BMI category (low vs high, 43% vs 51%, p=0.18) or participant rank (junior vs senior, 41% vs 51%, p=0.10). CONCLUSION: Overall accuracy of ICD insertion site was low, and appropriate accuracy was only associated with greater participant experience and left sided placement. Further studies to determine methods to improve ICD placement accuracy are needed. African Federation for Emergency Medicine 2022-12 2022-11-16 /pmc/articles/PMC9674875/ /pubmed/36415447 http://dx.doi.org/10.1016/j.afjem.2022.10.011 Text en © 2022 Published by Elsevier B.V. on behalf of African Federation for Emergency Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
Korda, Tessa
Baillie-Stanton, Tammy
Goldstein, Lara Nicole
An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement
title An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement
title_full An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement
title_fullStr An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement
title_full_unstemmed An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement
title_short An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement
title_sort observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674875/
https://www.ncbi.nlm.nih.gov/pubmed/36415447
http://dx.doi.org/10.1016/j.afjem.2022.10.011
work_keys_str_mv AT kordatessa anobservationalsimulationbasedstudyoftheaccuracyofintercostaldrainplacementandfactorsinfluencingplacement
AT bailliestantontammy anobservationalsimulationbasedstudyoftheaccuracyofintercostaldrainplacementandfactorsinfluencingplacement
AT goldsteinlaranicole anobservationalsimulationbasedstudyoftheaccuracyofintercostaldrainplacementandfactorsinfluencingplacement
AT kordatessa observationalsimulationbasedstudyoftheaccuracyofintercostaldrainplacementandfactorsinfluencingplacement
AT bailliestantontammy observationalsimulationbasedstudyoftheaccuracyofintercostaldrainplacementandfactorsinfluencingplacement
AT goldsteinlaranicole observationalsimulationbasedstudyoftheaccuracyofintercostaldrainplacementandfactorsinfluencingplacement