Infective endocarditis of a left atrial appendage closure device: a case report and literature review
BACKGROUND: Due to advances in interventional cardiology in recent years, more and more patients are currently receiving cardiac devices, with a subsequent increase in the number of patients with device-associated endocarditis. Device-associated endocarditis is a life-threatening disease with specia...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9675590/ https://www.ncbi.nlm.nih.gov/pubmed/36415684 http://dx.doi.org/10.1093/ehjcr/ytac434 |
Sumario: | BACKGROUND: Due to advances in interventional cardiology in recent years, more and more patients are currently receiving cardiac devices, with a subsequent increase in the number of patients with device-associated endocarditis. Device-associated endocarditis is a life-threatening disease with special diagnostic and therapeutic challenges. Interventional devices for left atrial appendage (LAA) closure have been available for several years. However, there have been very few case reports of LAA closure device–associated endocarditis. CASE SUMMARY: An 83-year-old woman presented with fever and fatigue. She had a history of permanent atrial fibrillation and recurrent bleeding on oral anticoagulation. Consequently, the patient underwent interventional LAA closure ∼20 months earlier. Blood cultures grew Staphylococcus aureus. Transoesophageal echocardiography revealed an LAA closure device–associated mobile, echo-dense mass that was consistent with infectious vegetation in this clinical context. Intravenous antibiotic therapy was started, and our heart team recommended complete removal of the device, which the patient refused. The patient subsequently died as a result of progressive endocarditis and multiple pre-existing co-morbidities. DISCUSSION: Left atrial appendage occlusion device–associated endocarditis has rarely been reported. Due to the increase in LAA closure device implantation, device-associated endocarditis is expected to increase in the future. Transoesophageal echocardiography is required for correct diagnosis. Our case report suggests that an infection can occur long after implantation. |
---|