High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability

CATEGORY: Ankle INTRODUCTION/PURPOSE: The manual traditional anterior drawer test (ADT) is essential for the treatment decision of chronic ankle instability, but have been pointed out of comparatively low reproducibility and accuracy, especially in less experienced hands. To clarify the inter-examin...

Descripción completa

Detalles Bibliográficos
Autores principales: Murahashi, Yasutaka, Teramoto, Atsushi, Takahashi, Katsunori, Watanabe, Kota, Yamashita, Toshihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9676296/
http://dx.doi.org/10.1177/2473011421S00833
_version_ 1784833562485194752
author Murahashi, Yasutaka
Teramoto, Atsushi
Takahashi, Katsunori
Watanabe, Kota
Yamashita, Toshihiko
author_facet Murahashi, Yasutaka
Teramoto, Atsushi
Takahashi, Katsunori
Watanabe, Kota
Yamashita, Toshihiko
author_sort Murahashi, Yasutaka
collection PubMed
description CATEGORY: Ankle INTRODUCTION/PURPOSE: The manual traditional anterior drawer test (ADT) is essential for the treatment decision of chronic ankle instability, but have been pointed out of comparatively low reproducibility and accuracy, especially in less experienced hands. To clarify the inter-examiner reproducibility, we compared the actual distance of anterior translation between the junior and senior examiner in the ADT. We also evaluate the diagnostic abilities of the traditional ADT and a novel modified ADT, fixed ADT. METHODS: Thirty ankles were included in this study and the ankle instability was defined by the stress radiography. All subjects were performed two methods of manual ADT by junior and senior examiner, and judged the ankle instability in a blinded fashion. The anterior drawer distance was calculated from the lengthening measured by the capacitance-type sensor device. RESULTS: The amount of anterior translation of junior examiner was significantly lower than senior examiner in the traditional ADT (3.3 vs. 4.5 mm, p=0.016), while, there was no significant difference between two examiners in the fixed ADT (4.6 vs. 4.1 mm, p=0.168). The inter-examiner reliability of fixed ADT was higher than traditional ADT. In the junior examiner, the diagnostic accuracy of the fixed ADT was higher than that of traditional ADT (sensitivity, 0.40 vs. 0.80; specificity, 0.75 vs. 0.80, respectively). CONCLUSION: Fixed ADT may have advantage for a simple manual test of ankle instability as a method with less error between examiners.
format Online
Article
Text
id pubmed-9676296
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-96762962022-11-22 High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability Murahashi, Yasutaka Teramoto, Atsushi Takahashi, Katsunori Watanabe, Kota Yamashita, Toshihiko Foot Ankle Orthop Article CATEGORY: Ankle INTRODUCTION/PURPOSE: The manual traditional anterior drawer test (ADT) is essential for the treatment decision of chronic ankle instability, but have been pointed out of comparatively low reproducibility and accuracy, especially in less experienced hands. To clarify the inter-examiner reproducibility, we compared the actual distance of anterior translation between the junior and senior examiner in the ADT. We also evaluate the diagnostic abilities of the traditional ADT and a novel modified ADT, fixed ADT. METHODS: Thirty ankles were included in this study and the ankle instability was defined by the stress radiography. All subjects were performed two methods of manual ADT by junior and senior examiner, and judged the ankle instability in a blinded fashion. The anterior drawer distance was calculated from the lengthening measured by the capacitance-type sensor device. RESULTS: The amount of anterior translation of junior examiner was significantly lower than senior examiner in the traditional ADT (3.3 vs. 4.5 mm, p=0.016), while, there was no significant difference between two examiners in the fixed ADT (4.6 vs. 4.1 mm, p=0.168). The inter-examiner reliability of fixed ADT was higher than traditional ADT. In the junior examiner, the diagnostic accuracy of the fixed ADT was higher than that of traditional ADT (sensitivity, 0.40 vs. 0.80; specificity, 0.75 vs. 0.80, respectively). CONCLUSION: Fixed ADT may have advantage for a simple manual test of ankle instability as a method with less error between examiners. SAGE Publications 2022-11-16 /pmc/articles/PMC9676296/ http://dx.doi.org/10.1177/2473011421S00833 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Murahashi, Yasutaka
Teramoto, Atsushi
Takahashi, Katsunori
Watanabe, Kota
Yamashita, Toshihiko
High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability
title High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability
title_full High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability
title_fullStr High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability
title_full_unstemmed High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability
title_short High Reproducibility of a Novel Fixed Anterior Drawer Test for Diagnosing Ankle Instability
title_sort high reproducibility of a novel fixed anterior drawer test for diagnosing ankle instability
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9676296/
http://dx.doi.org/10.1177/2473011421S00833
work_keys_str_mv AT murahashiyasutaka highreproducibilityofanovelfixedanteriordrawertestfordiagnosingankleinstability
AT teramotoatsushi highreproducibilityofanovelfixedanteriordrawertestfordiagnosingankleinstability
AT takahashikatsunori highreproducibilityofanovelfixedanteriordrawertestfordiagnosingankleinstability
AT watanabekota highreproducibilityofanovelfixedanteriordrawertestfordiagnosingankleinstability
AT yamashitatoshihiko highreproducibilityofanovelfixedanteriordrawertestfordiagnosingankleinstability