Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis
BACKGROUND: Drug-coated balloon (DCB) is a novel and effective device for coronary artery disease patients with in-stent restenosis (ISR). However, the incidence and possible influencing factors associated with binary restenosis have not yet been adequately assessed. METHODS: The data are extracted...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9677633/ https://www.ncbi.nlm.nih.gov/pubmed/36404303 http://dx.doi.org/10.1186/s12872-022-02923-z |
_version_ | 1784833846510878720 |
---|---|
author | Xue, Weihao Ma, Jun Yu, Xiaojie Ruan, Zhisheng Sun, Yuanxue Wu, Tianbo Zhang, Xinmin Wu, Lianpin |
author_facet | Xue, Weihao Ma, Jun Yu, Xiaojie Ruan, Zhisheng Sun, Yuanxue Wu, Tianbo Zhang, Xinmin Wu, Lianpin |
author_sort | Xue, Weihao |
collection | PubMed |
description | BACKGROUND: Drug-coated balloon (DCB) is a novel and effective device for coronary artery disease patients with in-stent restenosis (ISR). However, the incidence and possible influencing factors associated with binary restenosis have not yet been adequately assessed. METHODS: The data are extracted from a prospective, multicenter, randomized controlled trial. A total of 211 patients with ISR were enrolled at 13 centers from August 2017 to October 2018 and treated with DCB. At the 9-month coronary angiographic follow-up, patients were divided into restenosis and non-restenosis groups, and demographic data, lesion features, and laboratory tests were retrospectively reviewed. Furthermore, logistic regression analysis was used to identify possible influencing factors. RESULTS: All patients successfully underwent treatment, and 166 patients with 190 lesions took part in angiography follow-ups at 9 months. Of these, 41 patients with 44 target lesions developed restenosis following treatment, and the incidence of ISR was 24.7%. There were significant differences in the average length of target lesions and the number of multivessel lesions and fasting plasma glucose (FBG) between the two groups (p < 0.05). Demographic data, cardiac risk factors, left ventricular ejection fractions (LVEF), blood routine tests, biochemical tests, and other features of devices and lesions showed no difference. Logistic regression analyses showed that FBG > 6.1 mmol/L (OR: 7.185 95% CI: 2.939–17.567 P < 0.001) and length of lesion (OR:1.046 95% CI: 1.001–1.093 P = 0.046) were associated risk factors. CONCLUSIONS: The longer length of lesions, more target lesions and FBG > 6.1 mmol/L per individual may be characteristics of patients showing ISR following treatment. Studies with larger sample size, and more complete follow-up data are needed in the future to expend on these findings. TRIAL REGISTRATION: No.: NCT04213378, first posted date (30/12/2019). |
format | Online Article Text |
id | pubmed-9677633 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-96776332022-11-22 Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis Xue, Weihao Ma, Jun Yu, Xiaojie Ruan, Zhisheng Sun, Yuanxue Wu, Tianbo Zhang, Xinmin Wu, Lianpin BMC Cardiovasc Disord Research BACKGROUND: Drug-coated balloon (DCB) is a novel and effective device for coronary artery disease patients with in-stent restenosis (ISR). However, the incidence and possible influencing factors associated with binary restenosis have not yet been adequately assessed. METHODS: The data are extracted from a prospective, multicenter, randomized controlled trial. A total of 211 patients with ISR were enrolled at 13 centers from August 2017 to October 2018 and treated with DCB. At the 9-month coronary angiographic follow-up, patients were divided into restenosis and non-restenosis groups, and demographic data, lesion features, and laboratory tests were retrospectively reviewed. Furthermore, logistic regression analysis was used to identify possible influencing factors. RESULTS: All patients successfully underwent treatment, and 166 patients with 190 lesions took part in angiography follow-ups at 9 months. Of these, 41 patients with 44 target lesions developed restenosis following treatment, and the incidence of ISR was 24.7%. There were significant differences in the average length of target lesions and the number of multivessel lesions and fasting plasma glucose (FBG) between the two groups (p < 0.05). Demographic data, cardiac risk factors, left ventricular ejection fractions (LVEF), blood routine tests, biochemical tests, and other features of devices and lesions showed no difference. Logistic regression analyses showed that FBG > 6.1 mmol/L (OR: 7.185 95% CI: 2.939–17.567 P < 0.001) and length of lesion (OR:1.046 95% CI: 1.001–1.093 P = 0.046) were associated risk factors. CONCLUSIONS: The longer length of lesions, more target lesions and FBG > 6.1 mmol/L per individual may be characteristics of patients showing ISR following treatment. Studies with larger sample size, and more complete follow-up data are needed in the future to expend on these findings. TRIAL REGISTRATION: No.: NCT04213378, first posted date (30/12/2019). BioMed Central 2022-11-20 /pmc/articles/PMC9677633/ /pubmed/36404303 http://dx.doi.org/10.1186/s12872-022-02923-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Xue, Weihao Ma, Jun Yu, Xiaojie Ruan, Zhisheng Sun, Yuanxue Wu, Tianbo Zhang, Xinmin Wu, Lianpin Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis |
title | Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis |
title_full | Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis |
title_fullStr | Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis |
title_full_unstemmed | Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis |
title_short | Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis |
title_sort | analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9677633/ https://www.ncbi.nlm.nih.gov/pubmed/36404303 http://dx.doi.org/10.1186/s12872-022-02923-z |
work_keys_str_mv | AT xueweihao analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis AT majun analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis AT yuxiaojie analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis AT ruanzhisheng analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis AT sunyuanxue analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis AT wutianbo analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis AT zhangxinmin analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis AT wulianpin analysisoftheincidenceandinfluencingfactorsassociatedwithbinaryrestenosisoftargetlesionsafterdrugcoatedballoonangioplastyforpatientswithinstentrestenosis |