Cargando…
Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review
INTRODUCTION: Prolonged mechanical ventilation (PMV) and weaning failure are factors associated with prolonged hospital length of stay and increased morbidity and mortality. In addition to the burden these places on patients and their families, it also imposes high costs on the public health system....
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
S. Karger AG
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9677859/ https://www.ncbi.nlm.nih.gov/pubmed/35977525 http://dx.doi.org/10.1159/000525604 |
_version_ | 1784833881960087552 |
---|---|
author | Trudzinski, Franziska C. Neetz, Benjamin Bornitz, Florian Müller, Michael Weis, Aline Kronsteiner, Dorothea Herth, Felix J.F. Sturm, Noemi Gassmann, Vicky Frerk, Timm Neurohr, Claus Ghiani, Alessandro Joves, Biljana Schneider, Armin Szecsenyi, Joachim von Schumann, Selina Meis, Jan |
author_facet | Trudzinski, Franziska C. Neetz, Benjamin Bornitz, Florian Müller, Michael Weis, Aline Kronsteiner, Dorothea Herth, Felix J.F. Sturm, Noemi Gassmann, Vicky Frerk, Timm Neurohr, Claus Ghiani, Alessandro Joves, Biljana Schneider, Armin Szecsenyi, Joachim von Schumann, Selina Meis, Jan |
author_sort | Trudzinski, Franziska C. |
collection | PubMed |
description | INTRODUCTION: Prolonged mechanical ventilation (PMV) and weaning failure are factors associated with prolonged hospital length of stay and increased morbidity and mortality. In addition to the burden these places on patients and their families, it also imposes high costs on the public health system. The aim of this systematic review was to identify risk factors for PMV and weaning failure. METHODS: The study was conducted according to PRISMA guidelines. After a comprehensive search of the COCHRANE Library, CINHAL, Web of Science, MEDLINE, and the LILACS Database a PubMed request was made on June 8, 2020. Studies that examined risk factors for PMV, defined as mechanical ventilation ≥96 h, weaning failure, and prolonged weaning in German and English were considered eligible; reviews, meta-analyses, and studies in very specific patient populations whose results are not necessarily applicable to the majority of ICU patients as well as pediatric studies were excluded from the analysis. This systematic review was registered in the PROSPERO register under the number CRD42021271038. RESULTS: Of 532 articles identified, 23 studies with a total of 23,418 patients met the inclusion criteria. Fourteen studies investigated risk factors of PMV including prolonged weaning, 9 studies analyzed risk factors of weaning failure. The concrete definitions of these outcomes varied considerably between studies. For PMV, a variety of risk factors were identified, including comorbidities, site of intubation, various laboratory or blood gas parameters, ventilator settings, functional parameters, and critical care scoring systems. The risk of weaning failure was mainly related to age, previous home mechanical ventilation (HMV), cause of ventilation, and preexisting underlying diseases. Elevated PaCO(2) values during spontaneous breathing trials were indicative of prolonged weaning and weaning failure. CONCLUSION: A direct comparison of risk factors was not possible because of the heterogeneity of the studies. The large number of different definitions and relevant parameters reflects the heterogeneity of patients undergoing PMV and those discharged to HMV after unsuccessful weaning. Multidimensional scores are more likely to reflect the full spectrum of patients ventilated in different ICUs than single risk factors. |
format | Online Article Text |
id | pubmed-9677859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | S. Karger AG |
record_format | MEDLINE/PubMed |
spelling | pubmed-96778592022-11-22 Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review Trudzinski, Franziska C. Neetz, Benjamin Bornitz, Florian Müller, Michael Weis, Aline Kronsteiner, Dorothea Herth, Felix J.F. Sturm, Noemi Gassmann, Vicky Frerk, Timm Neurohr, Claus Ghiani, Alessandro Joves, Biljana Schneider, Armin Szecsenyi, Joachim von Schumann, Selina Meis, Jan Respiration Systematic Review and Meta-Analysis INTRODUCTION: Prolonged mechanical ventilation (PMV) and weaning failure are factors associated with prolonged hospital length of stay and increased morbidity and mortality. In addition to the burden these places on patients and their families, it also imposes high costs on the public health system. The aim of this systematic review was to identify risk factors for PMV and weaning failure. METHODS: The study was conducted according to PRISMA guidelines. After a comprehensive search of the COCHRANE Library, CINHAL, Web of Science, MEDLINE, and the LILACS Database a PubMed request was made on June 8, 2020. Studies that examined risk factors for PMV, defined as mechanical ventilation ≥96 h, weaning failure, and prolonged weaning in German and English were considered eligible; reviews, meta-analyses, and studies in very specific patient populations whose results are not necessarily applicable to the majority of ICU patients as well as pediatric studies were excluded from the analysis. This systematic review was registered in the PROSPERO register under the number CRD42021271038. RESULTS: Of 532 articles identified, 23 studies with a total of 23,418 patients met the inclusion criteria. Fourteen studies investigated risk factors of PMV including prolonged weaning, 9 studies analyzed risk factors of weaning failure. The concrete definitions of these outcomes varied considerably between studies. For PMV, a variety of risk factors were identified, including comorbidities, site of intubation, various laboratory or blood gas parameters, ventilator settings, functional parameters, and critical care scoring systems. The risk of weaning failure was mainly related to age, previous home mechanical ventilation (HMV), cause of ventilation, and preexisting underlying diseases. Elevated PaCO(2) values during spontaneous breathing trials were indicative of prolonged weaning and weaning failure. CONCLUSION: A direct comparison of risk factors was not possible because of the heterogeneity of the studies. The large number of different definitions and relevant parameters reflects the heterogeneity of patients undergoing PMV and those discharged to HMV after unsuccessful weaning. Multidimensional scores are more likely to reflect the full spectrum of patients ventilated in different ICUs than single risk factors. S. Karger AG 2022-10 2022-08-17 /pmc/articles/PMC9677859/ /pubmed/35977525 http://dx.doi.org/10.1159/000525604 Text en Copyright © 2022 by The Author(s). Published by S. Karger AG, Basel https://creativecommons.org/licenses/by/4.0/This article is licensed under the Creative Commons Attribution 4.0 International License (CC BY). Usage, derivative works and distribution are permitted provided that proper credit is given to the author and the original publisher. |
spellingShingle | Systematic Review and Meta-Analysis Trudzinski, Franziska C. Neetz, Benjamin Bornitz, Florian Müller, Michael Weis, Aline Kronsteiner, Dorothea Herth, Felix J.F. Sturm, Noemi Gassmann, Vicky Frerk, Timm Neurohr, Claus Ghiani, Alessandro Joves, Biljana Schneider, Armin Szecsenyi, Joachim von Schumann, Selina Meis, Jan Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review |
title | Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review |
title_full | Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review |
title_fullStr | Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review |
title_full_unstemmed | Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review |
title_short | Risk Factors for Prolonged Mechanical Ventilation and Weaning Failure: A Systematic Review |
title_sort | risk factors for prolonged mechanical ventilation and weaning failure: a systematic review |
topic | Systematic Review and Meta-Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9677859/ https://www.ncbi.nlm.nih.gov/pubmed/35977525 http://dx.doi.org/10.1159/000525604 |
work_keys_str_mv | AT trudzinskifranziskac riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT neetzbenjamin riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT bornitzflorian riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT mullermichael riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT weisaline riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT kronsteinerdorothea riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT herthfelixjf riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT sturmnoemi riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT gassmannvicky riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT frerktimm riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT neurohrclaus riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT ghianialessandro riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT jovesbiljana riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT schneiderarmin riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT szecsenyijoachim riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT vonschumannselina riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview AT meisjan riskfactorsforprolongedmechanicalventilationandweaningfailureasystematicreview |