Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices
PURPOSE: To compare the astigmatism prediction accuracy for toric intraocular lens (IOL) implantation between two swept-source optical coherence tomography (SS-OCT) devices: Argos (Movu, a Santec Company) and the IOLMaster 700 (Carl Zeiss Meditec). METHODS: This was a retrospective chart review of 5...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9677927/ https://www.ncbi.nlm.nih.gov/pubmed/36419565 http://dx.doi.org/10.2147/OPTH.S378019 |
_version_ | 1784833897399320576 |
---|---|
author | Melendez, Robert F Smits, Gerard Nguyen, Thao Ruffaner-Hanson, Chaselyn D Ortiz, Danielle Hall, Brad |
author_facet | Melendez, Robert F Smits, Gerard Nguyen, Thao Ruffaner-Hanson, Chaselyn D Ortiz, Danielle Hall, Brad |
author_sort | Melendez, Robert F |
collection | PubMed |
description | PURPOSE: To compare the astigmatism prediction accuracy for toric intraocular lens (IOL) implantation between two swept-source optical coherence tomography (SS-OCT) devices: Argos (Movu, a Santec Company) and the IOLMaster 700 (Carl Zeiss Meditec). METHODS: This was a retrospective chart review of 59 eyes (44 patients) with corneal astigmatism and cataract that underwent cataract surgery or refractive lens exchange surgery with a toric IOL. Biometry was performed on all patients prior to cataract surgery and the Barrett toric IOL calculator was used. Visual acuity was measured postoperatively. Manifest refraction was measured at 1 month and compared to the predicted postoperative residual refraction. Preoperative K measurements between devices were also compared. RESULTS: Mean cylinder prediction error was −0.17 ± 0.43 for Argos and 0.12 ± 0.56 for IOLMaster 700. The cylinder prediction error 0.5 D or less was not significantly different between the devices, with 83.1% (49 eyes) for Argos and 76.3% (45 eyes) for IOLMaster 700 (p = 0.206). Spherical equivalent prediction error was 0.13 ± 0.39 for Argos and 0.25 ± 0.50 for IOLMaster 700. The mean spherical equivalent prediction error 0.5 D or less was significantly different between the devices, with 79.7% (47 eyes) for Argos and 61.0% (36 eyes) for IOLMaster 700 (p = 0.016). CONCLUSION: The prediction accuracies were similar between the devices, except for spherical equivalent, where a higher percentage of eyes were 0.5 D or less of the prediction with the Argos compared to the IOLMaster. |
format | Online Article Text |
id | pubmed-9677927 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-96779272022-11-22 Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices Melendez, Robert F Smits, Gerard Nguyen, Thao Ruffaner-Hanson, Chaselyn D Ortiz, Danielle Hall, Brad Clin Ophthalmol Original Research PURPOSE: To compare the astigmatism prediction accuracy for toric intraocular lens (IOL) implantation between two swept-source optical coherence tomography (SS-OCT) devices: Argos (Movu, a Santec Company) and the IOLMaster 700 (Carl Zeiss Meditec). METHODS: This was a retrospective chart review of 59 eyes (44 patients) with corneal astigmatism and cataract that underwent cataract surgery or refractive lens exchange surgery with a toric IOL. Biometry was performed on all patients prior to cataract surgery and the Barrett toric IOL calculator was used. Visual acuity was measured postoperatively. Manifest refraction was measured at 1 month and compared to the predicted postoperative residual refraction. Preoperative K measurements between devices were also compared. RESULTS: Mean cylinder prediction error was −0.17 ± 0.43 for Argos and 0.12 ± 0.56 for IOLMaster 700. The cylinder prediction error 0.5 D or less was not significantly different between the devices, with 83.1% (49 eyes) for Argos and 76.3% (45 eyes) for IOLMaster 700 (p = 0.206). Spherical equivalent prediction error was 0.13 ± 0.39 for Argos and 0.25 ± 0.50 for IOLMaster 700. The mean spherical equivalent prediction error 0.5 D or less was significantly different between the devices, with 79.7% (47 eyes) for Argos and 61.0% (36 eyes) for IOLMaster 700 (p = 0.016). CONCLUSION: The prediction accuracies were similar between the devices, except for spherical equivalent, where a higher percentage of eyes were 0.5 D or less of the prediction with the Argos compared to the IOLMaster. Dove 2022-11-17 /pmc/articles/PMC9677927/ /pubmed/36419565 http://dx.doi.org/10.2147/OPTH.S378019 Text en © 2022 Melendez et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Melendez, Robert F Smits, Gerard Nguyen, Thao Ruffaner-Hanson, Chaselyn D Ortiz, Danielle Hall, Brad Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices |
title | Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices |
title_full | Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices |
title_fullStr | Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices |
title_full_unstemmed | Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices |
title_short | Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices |
title_sort | comparison of astigmatism prediction accuracy for toric lens implantation from two swept-source optical coherence tomography devices |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9677927/ https://www.ncbi.nlm.nih.gov/pubmed/36419565 http://dx.doi.org/10.2147/OPTH.S378019 |
work_keys_str_mv | AT melendezrobertf comparisonofastigmatismpredictionaccuracyfortoriclensimplantationfromtwosweptsourceopticalcoherencetomographydevices AT smitsgerard comparisonofastigmatismpredictionaccuracyfortoriclensimplantationfromtwosweptsourceopticalcoherencetomographydevices AT nguyenthao comparisonofastigmatismpredictionaccuracyfortoriclensimplantationfromtwosweptsourceopticalcoherencetomographydevices AT ruffanerhansonchaselynd comparisonofastigmatismpredictionaccuracyfortoriclensimplantationfromtwosweptsourceopticalcoherencetomographydevices AT ortizdanielle comparisonofastigmatismpredictionaccuracyfortoriclensimplantationfromtwosweptsourceopticalcoherencetomographydevices AT hallbrad comparisonofastigmatismpredictionaccuracyfortoriclensimplantationfromtwosweptsourceopticalcoherencetomographydevices |