Cargando…
Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith
OBJECTIVE: To investigate the clinical application of the three-dimensional (3D) radiomics model of the CT image in the diagnosis and identification of ureteral calculus and phlebolith. METHOD: Sixty-one cases of ureteral calculus and 61 cases of phlebolith were retrospectively investigated. The enr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9678460/ https://www.ncbi.nlm.nih.gov/pubmed/36474549 http://dx.doi.org/10.1155/2022/5478908 |
_version_ | 1784833989774671872 |
---|---|
author | Yu, Qiuyue Liu, Jiaqi Lin, Huashan Lei, Pinggui Fan, Bing |
author_facet | Yu, Qiuyue Liu, Jiaqi Lin, Huashan Lei, Pinggui Fan, Bing |
author_sort | Yu, Qiuyue |
collection | PubMed |
description | OBJECTIVE: To investigate the clinical application of the three-dimensional (3D) radiomics model of the CT image in the diagnosis and identification of ureteral calculus and phlebolith. METHOD: Sixty-one cases of ureteral calculus and 61 cases of phlebolith were retrospectively investigated. The enrolled patients were randomly categorized into the training set (n = 86) and the testing set (n = 36) with a ratio of 7 : 3. The plain CT scan images of all samples were manually segmented by the ITK-SNAP software, followed by radiomics analysis through the Analysis Kit software. A total of 1316 texture features were extracted. Then, the maximum correlation minimum redundancy criterion and the least absolute shrinkage and selection operator algorithm were used for texture feature selection. The feature subset with the most predictability was selected to establish the 3D radiomics model. The performance of the model was evaluated by the receiver operating characteristic (ROC) curve, and the area under the ROC curve (AUC) was also calculated. Additionally, the decision curve was used to evaluate the clinical application of the model. RESULTS: The 10 selected radiomics features were significantly related to the identification and diagnosis of ureteral calculus and phlebolith. The radiomics model showed good identification efficiency for ureteral calculus and phlebolith in the training set (AUC = 0.98; 95%CI: 0.96–1.00) and testing set (AUC = 0.98; 95%CI: 0.95–1.00). The decision curve thus demonstrated the clinical application of the radiomics model. CONCLUSIONS: The 3D radiomics model based on plain CT scan images indicated good performance in the identification and prediction of ureteral calculus and phlebolith and was expected to provide an effective detection method for clinical diagnosis. |
format | Online Article Text |
id | pubmed-9678460 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-96784602022-12-05 Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith Yu, Qiuyue Liu, Jiaqi Lin, Huashan Lei, Pinggui Fan, Bing Int J Clin Pract Research Article OBJECTIVE: To investigate the clinical application of the three-dimensional (3D) radiomics model of the CT image in the diagnosis and identification of ureteral calculus and phlebolith. METHOD: Sixty-one cases of ureteral calculus and 61 cases of phlebolith were retrospectively investigated. The enrolled patients were randomly categorized into the training set (n = 86) and the testing set (n = 36) with a ratio of 7 : 3. The plain CT scan images of all samples were manually segmented by the ITK-SNAP software, followed by radiomics analysis through the Analysis Kit software. A total of 1316 texture features were extracted. Then, the maximum correlation minimum redundancy criterion and the least absolute shrinkage and selection operator algorithm were used for texture feature selection. The feature subset with the most predictability was selected to establish the 3D radiomics model. The performance of the model was evaluated by the receiver operating characteristic (ROC) curve, and the area under the ROC curve (AUC) was also calculated. Additionally, the decision curve was used to evaluate the clinical application of the model. RESULTS: The 10 selected radiomics features were significantly related to the identification and diagnosis of ureteral calculus and phlebolith. The radiomics model showed good identification efficiency for ureteral calculus and phlebolith in the training set (AUC = 0.98; 95%CI: 0.96–1.00) and testing set (AUC = 0.98; 95%CI: 0.95–1.00). The decision curve thus demonstrated the clinical application of the radiomics model. CONCLUSIONS: The 3D radiomics model based on plain CT scan images indicated good performance in the identification and prediction of ureteral calculus and phlebolith and was expected to provide an effective detection method for clinical diagnosis. Hindawi 2022-11-14 /pmc/articles/PMC9678460/ /pubmed/36474549 http://dx.doi.org/10.1155/2022/5478908 Text en Copyright © 2022 Qiuyue Yu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Yu, Qiuyue Liu, Jiaqi Lin, Huashan Lei, Pinggui Fan, Bing Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith |
title | Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith |
title_full | Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith |
title_fullStr | Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith |
title_full_unstemmed | Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith |
title_short | Application of Radiomics Model of CT Images in the Identification of Ureteral Calculus and Phlebolith |
title_sort | application of radiomics model of ct images in the identification of ureteral calculus and phlebolith |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9678460/ https://www.ncbi.nlm.nih.gov/pubmed/36474549 http://dx.doi.org/10.1155/2022/5478908 |
work_keys_str_mv | AT yuqiuyue applicationofradiomicsmodelofctimagesintheidentificationofureteralcalculusandphlebolith AT liujiaqi applicationofradiomicsmodelofctimagesintheidentificationofureteralcalculusandphlebolith AT linhuashan applicationofradiomicsmodelofctimagesintheidentificationofureteralcalculusandphlebolith AT leipinggui applicationofradiomicsmodelofctimagesintheidentificationofureteralcalculusandphlebolith AT fanbing applicationofradiomicsmodelofctimagesintheidentificationofureteralcalculusandphlebolith |