Cargando…

Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds

PURPOSE: To establish a non-invasive test method for the rapid detection of severe ischemia (SI) in the limbs in patients with peripheral arterial disease (PAD). METHODS: Between November 2019 and May 2021, 22 patients admitted for PAD to 2 hospitals agreed to participate in the study. All patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Katsui, Sotaro, Yamamoto, Yohei, Kudo, Toshifumi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9679796/
https://www.ncbi.nlm.nih.gov/pubmed/35968758
http://dx.doi.org/10.1177/15385744221120977
_version_ 1784834278900629504
author Katsui, Sotaro
Yamamoto, Yohei
Kudo, Toshifumi
author_facet Katsui, Sotaro
Yamamoto, Yohei
Kudo, Toshifumi
author_sort Katsui, Sotaro
collection PubMed
description PURPOSE: To establish a non-invasive test method for the rapid detection of severe ischemia (SI) in the limbs in patients with peripheral arterial disease (PAD). METHODS: Between November 2019 and May 2021, 22 patients admitted for PAD to 2 hospitals agreed to participate in the study. All patients underwent a local heating load (LHL) test. SI was defined as at least 1 ankle-brachial index value of <.4 and/or transcutaneous oximetry value of <30 mmHg. The other cases were classified as mild-to-moderate ischemia (MMI). The LHL test was performed simultaneously with 15 minutes of heating and measurement by attaching a blood flow meter measuring probe combined with a warmer to the patient’s dorsal foot. Evaluation consisted of 200-s periods from the start of heating to 800 seconds. For each period, perfusion value (PV) was evaluated, and slope was calculated graphically based on linear regression as PV fluctuation per minute. Test accuracy was calculated using a receiver operating characteristic curve. RESULTS: Twenty-four limbs of 18 patients were finally evaluated; 4 patients (2 with missing data, 1 with collagen disease, and 1 with embolism) were excluded, with 13 and 11 limbs in the SI and MMI groups, respectively. The SI group showed a significantly lower slope value in the first 200 seconds and lower PV at 200 seconds and thereafter. From the slope value, it was possible to detect SI with 85% sensitivity and 73% specificity at 200 seconds. PV could be determined with higher accuracy in periods after 200 seconds, with 85% sensitivity and 82% specificity at 800 seconds. CONCLUSIONS: Our non-invasive LHL test could be used as a rapid screening test to detect SI in limbs within 200 seconds, as well as a more accurate test to detect ischemia within 800 seconds.
format Online
Article
Text
id pubmed-9679796
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-96797962022-11-23 Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds Katsui, Sotaro Yamamoto, Yohei Kudo, Toshifumi Vasc Endovascular Surg Original Articles PURPOSE: To establish a non-invasive test method for the rapid detection of severe ischemia (SI) in the limbs in patients with peripheral arterial disease (PAD). METHODS: Between November 2019 and May 2021, 22 patients admitted for PAD to 2 hospitals agreed to participate in the study. All patients underwent a local heating load (LHL) test. SI was defined as at least 1 ankle-brachial index value of <.4 and/or transcutaneous oximetry value of <30 mmHg. The other cases were classified as mild-to-moderate ischemia (MMI). The LHL test was performed simultaneously with 15 minutes of heating and measurement by attaching a blood flow meter measuring probe combined with a warmer to the patient’s dorsal foot. Evaluation consisted of 200-s periods from the start of heating to 800 seconds. For each period, perfusion value (PV) was evaluated, and slope was calculated graphically based on linear regression as PV fluctuation per minute. Test accuracy was calculated using a receiver operating characteristic curve. RESULTS: Twenty-four limbs of 18 patients were finally evaluated; 4 patients (2 with missing data, 1 with collagen disease, and 1 with embolism) were excluded, with 13 and 11 limbs in the SI and MMI groups, respectively. The SI group showed a significantly lower slope value in the first 200 seconds and lower PV at 200 seconds and thereafter. From the slope value, it was possible to detect SI with 85% sensitivity and 73% specificity at 200 seconds. PV could be determined with higher accuracy in periods after 200 seconds, with 85% sensitivity and 82% specificity at 800 seconds. CONCLUSIONS: Our non-invasive LHL test could be used as a rapid screening test to detect SI in limbs within 200 seconds, as well as a more accurate test to detect ischemia within 800 seconds. SAGE Publications 2022-08-13 2023-01 /pmc/articles/PMC9679796/ /pubmed/35968758 http://dx.doi.org/10.1177/15385744221120977 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Katsui, Sotaro
Yamamoto, Yohei
Kudo, Toshifumi
Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds
title Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds
title_full Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds
title_fullStr Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds
title_full_unstemmed Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds
title_short Development of a Non-Invasive Local Heating Load Test to Detect Severe Limb Ischemia Within 200 seconds
title_sort development of a non-invasive local heating load test to detect severe limb ischemia within 200 seconds
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9679796/
https://www.ncbi.nlm.nih.gov/pubmed/35968758
http://dx.doi.org/10.1177/15385744221120977
work_keys_str_mv AT katsuisotaro developmentofanoninvasivelocalheatingloadtesttodetectseverelimbischemiawithin200seconds
AT yamamotoyohei developmentofanoninvasivelocalheatingloadtesttodetectseverelimbischemiawithin200seconds
AT kudotoshifumi developmentofanoninvasivelocalheatingloadtesttodetectseverelimbischemiawithin200seconds