Cargando…

Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique

CATEGORY: Trauma; Ankle INTRODUCTION/PURPOSE: Malleolar fractures are a common orthopedic injury representing 9% of all fractures with an increasing incidence. For fractures requiring surgical management, internal fixation with a locking plate is commonly used. In an effort to deliver more cost-effe...

Descripción completa

Detalles Bibliográficos
Autores principales: Ricci, Gianni, Stenslie, Noah, Jardaly, Achraf, Floyd, John CP., Harris, Robert M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9679837/
http://dx.doi.org/10.1177/2473011421S00907
_version_ 1784834289586667520
author Ricci, Gianni
Stenslie, Noah
Jardaly, Achraf
Floyd, John CP.
Harris, Robert M.
author_facet Ricci, Gianni
Stenslie, Noah
Jardaly, Achraf
Floyd, John CP.
Harris, Robert M.
author_sort Ricci, Gianni
collection PubMed
description CATEGORY: Trauma; Ankle INTRODUCTION/PURPOSE: Malleolar fractures are a common orthopedic injury representing 9% of all fractures with an increasing incidence. For fractures requiring surgical management, internal fixation with a locking plate is commonly used. In an effort to deliver more cost-effective care, we utilize a technique termed Steel Cross (Figure 1) for fixation of the lateral malleolus. This technique incorporates a 1/3 tubular nonlocking plate with 3.5mm/2.7mm screws angled in the distal fibula to interlock the threads for fixation. This can be used in lieu of locking distal fibular plates and offers a 24.4% cost reduction. This pilot study was performed to compare the safety and efficacy of the Steel Cross versus standard locking plates for lateral malleolar fractures. METHODS: This was a retrospective cohort study of patients who underwent open reduction and internal fixation for isolated lateral malleolar fractures. Consecutive patients treated with the Steel Cross were identified, and a control group of patients treated with a locking distal fibular plate was identified in a 1:1 ratio. Operative Technique: Standard direct lateral approach is used. Two 1.5mm cortical screws are placed lag by technique anterior to posterior perpendicular to the fracture. 1/3 tubular plate is contoured to distal fibula. A 3.5mm cortical screw is placed in 2nd-most distal hole unicortically. Three additional bicortical 3.5mm cortical screws are placed in the fibular shaft. Drill bit is used in the most distal hole angled obliquely proximal and posterior to the screw in the 2nd-most distal hole. 2.7mm cortical screw is then placed in that position interlocking the threads with the 3.5mm screw in the 2nd-most distal hole (Figure). RESULTS: The study included 48 patients divided equally between Steel Cross patients (n=24) and locking plate patients (n=24). The majority were female (n=34, 70.8%), with an average age of 41.5 years (range:18- 81 years) and body mass index BMI of 31.9 kg/m2 (18.1-69.2 kg/m2). Both groups were similar in the age, sex, smoking, and diabetes distribution. All patients achieved union, and none experienced instrumentation break or fixation failure. Nine total complications were encountered, the most common being symptomatic instrumentation (n=6). Patients treated with the steal cross had three complications (12.5%): 2 symptomatic instrumentation and 1 surgical site infection. The other group had 6 complications (25%): 4 symptomatic instrumentations, 1 surgical site infection, and 1 wound dehiscence. The complication rate was not significantly different between groups. CONCLUSION: Open reduction and internal fixation is a safe and effective treatment for lateral malleolus fractures. The Steel Cross technique represents a viable alternative to locking plates in providing stable fixation. This technique achieved excellent union rates (100%) with a complication profile similar to that of locking plates while reducing implant cost by 24.4%.
format Online
Article
Text
id pubmed-9679837
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-96798372022-11-23 Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique Ricci, Gianni Stenslie, Noah Jardaly, Achraf Floyd, John CP. Harris, Robert M. Foot Ankle Orthop Article CATEGORY: Trauma; Ankle INTRODUCTION/PURPOSE: Malleolar fractures are a common orthopedic injury representing 9% of all fractures with an increasing incidence. For fractures requiring surgical management, internal fixation with a locking plate is commonly used. In an effort to deliver more cost-effective care, we utilize a technique termed Steel Cross (Figure 1) for fixation of the lateral malleolus. This technique incorporates a 1/3 tubular nonlocking plate with 3.5mm/2.7mm screws angled in the distal fibula to interlock the threads for fixation. This can be used in lieu of locking distal fibular plates and offers a 24.4% cost reduction. This pilot study was performed to compare the safety and efficacy of the Steel Cross versus standard locking plates for lateral malleolar fractures. METHODS: This was a retrospective cohort study of patients who underwent open reduction and internal fixation for isolated lateral malleolar fractures. Consecutive patients treated with the Steel Cross were identified, and a control group of patients treated with a locking distal fibular plate was identified in a 1:1 ratio. Operative Technique: Standard direct lateral approach is used. Two 1.5mm cortical screws are placed lag by technique anterior to posterior perpendicular to the fracture. 1/3 tubular plate is contoured to distal fibula. A 3.5mm cortical screw is placed in 2nd-most distal hole unicortically. Three additional bicortical 3.5mm cortical screws are placed in the fibular shaft. Drill bit is used in the most distal hole angled obliquely proximal and posterior to the screw in the 2nd-most distal hole. 2.7mm cortical screw is then placed in that position interlocking the threads with the 3.5mm screw in the 2nd-most distal hole (Figure). RESULTS: The study included 48 patients divided equally between Steel Cross patients (n=24) and locking plate patients (n=24). The majority were female (n=34, 70.8%), with an average age of 41.5 years (range:18- 81 years) and body mass index BMI of 31.9 kg/m2 (18.1-69.2 kg/m2). Both groups were similar in the age, sex, smoking, and diabetes distribution. All patients achieved union, and none experienced instrumentation break or fixation failure. Nine total complications were encountered, the most common being symptomatic instrumentation (n=6). Patients treated with the steal cross had three complications (12.5%): 2 symptomatic instrumentation and 1 surgical site infection. The other group had 6 complications (25%): 4 symptomatic instrumentations, 1 surgical site infection, and 1 wound dehiscence. The complication rate was not significantly different between groups. CONCLUSION: Open reduction and internal fixation is a safe and effective treatment for lateral malleolus fractures. The Steel Cross technique represents a viable alternative to locking plates in providing stable fixation. This technique achieved excellent union rates (100%) with a complication profile similar to that of locking plates while reducing implant cost by 24.4%. SAGE Publications 2022-11-18 /pmc/articles/PMC9679837/ http://dx.doi.org/10.1177/2473011421S00907 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Ricci, Gianni
Stenslie, Noah
Jardaly, Achraf
Floyd, John CP.
Harris, Robert M.
Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique
title Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique
title_full Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique
title_fullStr Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique
title_full_unstemmed Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique
title_short Surgical Fixation of Lateral Malleolus Fractures with the Steel Cross Surgical Technique
title_sort surgical fixation of lateral malleolus fractures with the steel cross surgical technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9679837/
http://dx.doi.org/10.1177/2473011421S00907
work_keys_str_mv AT riccigianni surgicalfixationoflateralmalleolusfractureswiththesteelcrosssurgicaltechnique
AT stenslienoah surgicalfixationoflateralmalleolusfractureswiththesteelcrosssurgicaltechnique
AT jardalyachraf surgicalfixationoflateralmalleolusfractureswiththesteelcrosssurgicaltechnique
AT floydjohncp surgicalfixationoflateralmalleolusfractureswiththesteelcrosssurgicaltechnique
AT harrisrobertm surgicalfixationoflateralmalleolusfractureswiththesteelcrosssurgicaltechnique