Cargando…

Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis

Sarcopenia is a well-known highly prevalent muscle disease that severely impairs overall physical performance in elders, inducing a massive health-related economic burden. The widespread screening, diagnosis and treatment of sarcopenia are pivotal to restrain the disease progression and constrain it...

Descripción completa

Detalles Bibliográficos
Autores principales: Teixeira, Eduardo, Bohn, Lucimére, Guimarães, José Pedro, Marques-Aleixo, Inês
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680425/
https://www.ncbi.nlm.nih.gov/pubmed/36412610
http://dx.doi.org/10.3390/geriatrics7060121
_version_ 1784834414665007104
author Teixeira, Eduardo
Bohn, Lucimére
Guimarães, José Pedro
Marques-Aleixo, Inês
author_facet Teixeira, Eduardo
Bohn, Lucimére
Guimarães, José Pedro
Marques-Aleixo, Inês
author_sort Teixeira, Eduardo
collection PubMed
description Sarcopenia is a well-known highly prevalent muscle disease that severely impairs overall physical performance in elders, inducing a massive health-related economic burden. The widespread screening, diagnosis and treatment of sarcopenia are pivotal to restrain the disease progression and constrain its societal impact. Simple-to-use, portable, and reliable methods to evaluate sarcopenia are scarce, and sarcopenia-related assessments are typically done in several time-consuming stages. This study presents a portable digital system that enables a simple and intuitive method to evaluate sarcopenia—based on the European Working Group on Sarcopenia in Older People 2 (EWGSOP2) algorithm—including the four Find-Assess-Confirm-Severity (FACS) steps. The system comprises a mobile application (app); two wireless devices: a dynamometer (Gripwise) and a skinfold caliper (Lipowise); and a back-end website. To find cases, the SARC-F questionnaire is applied. To assess sarcopenia, the handgrip strength and the sit-to-stand tests are performed with the Gripwise and an application-embedded stopwatch, respectively. To confirm cases, anthropometric measures are performed, and muscle quantity is estimated with Lipowise. Finally, to assess severity, the app stopwatch grants the gait speed test application, evaluating physical performance. This step-by-step sarcopenia assessment results in a final grading according to the cut-off points of the EWGSOP2 criteria. All data is automatically encrypted and exported into a GDPR-compliant cloud platform, in which healthcare professionals can access and monitor their patients through the internet.
format Online
Article
Text
id pubmed-9680425
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96804252022-11-23 Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis Teixeira, Eduardo Bohn, Lucimére Guimarães, José Pedro Marques-Aleixo, Inês Geriatrics (Basel) Article Sarcopenia is a well-known highly prevalent muscle disease that severely impairs overall physical performance in elders, inducing a massive health-related economic burden. The widespread screening, diagnosis and treatment of sarcopenia are pivotal to restrain the disease progression and constrain its societal impact. Simple-to-use, portable, and reliable methods to evaluate sarcopenia are scarce, and sarcopenia-related assessments are typically done in several time-consuming stages. This study presents a portable digital system that enables a simple and intuitive method to evaluate sarcopenia—based on the European Working Group on Sarcopenia in Older People 2 (EWGSOP2) algorithm—including the four Find-Assess-Confirm-Severity (FACS) steps. The system comprises a mobile application (app); two wireless devices: a dynamometer (Gripwise) and a skinfold caliper (Lipowise); and a back-end website. To find cases, the SARC-F questionnaire is applied. To assess sarcopenia, the handgrip strength and the sit-to-stand tests are performed with the Gripwise and an application-embedded stopwatch, respectively. To confirm cases, anthropometric measures are performed, and muscle quantity is estimated with Lipowise. Finally, to assess severity, the app stopwatch grants the gait speed test application, evaluating physical performance. This step-by-step sarcopenia assessment results in a final grading according to the cut-off points of the EWGSOP2 criteria. All data is automatically encrypted and exported into a GDPR-compliant cloud platform, in which healthcare professionals can access and monitor their patients through the internet. MDPI 2022-10-25 /pmc/articles/PMC9680425/ /pubmed/36412610 http://dx.doi.org/10.3390/geriatrics7060121 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Teixeira, Eduardo
Bohn, Lucimére
Guimarães, José Pedro
Marques-Aleixo, Inês
Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis
title Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis
title_full Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis
title_fullStr Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis
title_full_unstemmed Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis
title_short Portable Digital Monitoring System for Sarcopenia Screening and Diagnosis
title_sort portable digital monitoring system for sarcopenia screening and diagnosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680425/
https://www.ncbi.nlm.nih.gov/pubmed/36412610
http://dx.doi.org/10.3390/geriatrics7060121
work_keys_str_mv AT teixeiraeduardo portabledigitalmonitoringsystemforsarcopeniascreeninganddiagnosis
AT bohnlucimere portabledigitalmonitoringsystemforsarcopeniascreeninganddiagnosis
AT guimaraesjosepedro portabledigitalmonitoringsystemforsarcopeniascreeninganddiagnosis
AT marquesaleixoines portabledigitalmonitoringsystemforsarcopeniascreeninganddiagnosis