Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting

Extrusion-based 3D bioprinting is a promising technique for fabricating multi-layered, complex biostructures, as it enables multi-material dispersion of bioinks with a straightforward procedure (particularly for users with limited additive manufacturing skills). Nonetheless, this method faces challe...

Descripción completa

Detalles Bibliográficos
Autores principales: Temirel, Mikail, Dabbagh, Sajjad Rahmani, Tasoglu, Savas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680455/
https://www.ncbi.nlm.nih.gov/pubmed/36412866
http://dx.doi.org/10.3390/jfb13040225
_version_ 1784834422113042432
author Temirel, Mikail
Dabbagh, Sajjad Rahmani
Tasoglu, Savas
author_facet Temirel, Mikail
Dabbagh, Sajjad Rahmani
Tasoglu, Savas
author_sort Temirel, Mikail
collection PubMed
description Extrusion-based 3D bioprinting is a promising technique for fabricating multi-layered, complex biostructures, as it enables multi-material dispersion of bioinks with a straightforward procedure (particularly for users with limited additive manufacturing skills). Nonetheless, this method faces challenges in retaining the shape fidelity of the 3D-bioprinted structure, i.e., the collapse of filament (bioink) due to gravity and/or spreading of the bioink owing to the low viscosity, ultimately complicating the fabrication of multi-layered designs that can maintain the desired pore structure. While low viscosity is required to ensure a continuous flow of material (without clogging), a bioink should be viscous enough to retain its shape post-printing, highlighting the importance of bioink properties optimization. Here, two quantitative analyses are performed to evaluate shape fidelity. First, the filament collapse deformation is evaluated by printing different concentrations of alginate and its crosslinker (calcium chloride) by a co-axial nozzle over a platform to observe the overhanging deformation over time at two different ambient temperatures. In addition, a mathematical model is developed to estimate Young’s modulus and filament collapse over time. Second, the printability of alginate is improved by optimizing gelatin concentrations and analyzing the pore size area. In addition, the biocompatibility of proposed bioinks is evaluated with a cell viability test. The proposed bioink (3% w/v gelatin in 4% alginate) yielded a 98% normalized pore number (high shape fidelity) while maintaining >90% cell viability five days after being bioprinted. Integration of quantitative analysis/simulations and 3D printing facilitate the determination of the optimum composition and concentration of different elements of a bioink to prevent filament collapse or bioink spreading (post-printing), ultimately resulting in high shape fidelity (i.e., retaining the shape) and printing quality.
format Online
Article
Text
id pubmed-9680455
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96804552022-11-23 Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting Temirel, Mikail Dabbagh, Sajjad Rahmani Tasoglu, Savas J Funct Biomater Article Extrusion-based 3D bioprinting is a promising technique for fabricating multi-layered, complex biostructures, as it enables multi-material dispersion of bioinks with a straightforward procedure (particularly for users with limited additive manufacturing skills). Nonetheless, this method faces challenges in retaining the shape fidelity of the 3D-bioprinted structure, i.e., the collapse of filament (bioink) due to gravity and/or spreading of the bioink owing to the low viscosity, ultimately complicating the fabrication of multi-layered designs that can maintain the desired pore structure. While low viscosity is required to ensure a continuous flow of material (without clogging), a bioink should be viscous enough to retain its shape post-printing, highlighting the importance of bioink properties optimization. Here, two quantitative analyses are performed to evaluate shape fidelity. First, the filament collapse deformation is evaluated by printing different concentrations of alginate and its crosslinker (calcium chloride) by a co-axial nozzle over a platform to observe the overhanging deformation over time at two different ambient temperatures. In addition, a mathematical model is developed to estimate Young’s modulus and filament collapse over time. Second, the printability of alginate is improved by optimizing gelatin concentrations and analyzing the pore size area. In addition, the biocompatibility of proposed bioinks is evaluated with a cell viability test. The proposed bioink (3% w/v gelatin in 4% alginate) yielded a 98% normalized pore number (high shape fidelity) while maintaining >90% cell viability five days after being bioprinted. Integration of quantitative analysis/simulations and 3D printing facilitate the determination of the optimum composition and concentration of different elements of a bioink to prevent filament collapse or bioink spreading (post-printing), ultimately resulting in high shape fidelity (i.e., retaining the shape) and printing quality. MDPI 2022-11-07 /pmc/articles/PMC9680455/ /pubmed/36412866 http://dx.doi.org/10.3390/jfb13040225 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Temirel, Mikail
Dabbagh, Sajjad Rahmani
Tasoglu, Savas
Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting
title Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting
title_full Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting
title_fullStr Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting
title_full_unstemmed Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting
title_short Shape Fidelity Evaluation of Alginate-Based Hydrogels through Extrusion-Based Bioprinting
title_sort shape fidelity evaluation of alginate-based hydrogels through extrusion-based bioprinting
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680455/
https://www.ncbi.nlm.nih.gov/pubmed/36412866
http://dx.doi.org/10.3390/jfb13040225
work_keys_str_mv AT temirelmikail shapefidelityevaluationofalginatebasedhydrogelsthroughextrusionbasedbioprinting
AT dabbaghsajjadrahmani shapefidelityevaluationofalginatebasedhydrogelsthroughextrusionbasedbioprinting
AT tasoglusavas shapefidelityevaluationofalginatebasedhydrogelsthroughextrusionbasedbioprinting