Cargando…

Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease

4D flow MRI allows time-resolved 3D velocity-encoded phase-contrast imaging for 3D visualization and quantification of aortic and intracardiac flow. Radiologists should be familiar with the principles of 4D flow MRI and methods for evaluating blood flow qualitatively and quantitatively. The most sub...

Descripción completa

Detalles Bibliográficos
Autores principales: Oyama-Manabe, Noriko, Aikawa, Tadao, Tsuneta, Satonori, Manabe, Osamu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680549/
https://www.ncbi.nlm.nih.gov/pubmed/34176866
http://dx.doi.org/10.2463/mrms.rev.2021-0030
_version_ 1784834444449808384
author Oyama-Manabe, Noriko
Aikawa, Tadao
Tsuneta, Satonori
Manabe, Osamu
author_facet Oyama-Manabe, Noriko
Aikawa, Tadao
Tsuneta, Satonori
Manabe, Osamu
author_sort Oyama-Manabe, Noriko
collection PubMed
description 4D flow MRI allows time-resolved 3D velocity-encoded phase-contrast imaging for 3D visualization and quantification of aortic and intracardiac flow. Radiologists should be familiar with the principles of 4D flow MRI and methods for evaluating blood flow qualitatively and quantitatively. The most substantial benefits of 4D flow MRI are that it enables the simultaneous comprehensive assessment of different vessels, and that retrospective analysis can be achieved in all vessels in any direction in the field of view, which is especially beneficial for patients with complicated congenital heart disease (CHD). For aortic valvular diseases, new parameters such as wall shear stress and energy loss may provide new prognostic values for 4D flow MRI. In this review, we introduce the clinical applications of 4D flow MRI for the visualization of blood flow and quantification of hemodynamic metrics in the setting of aortic valvular disease and CHD, including intracardiac shunt and coronary artery anomaly.
format Online
Article
Text
id pubmed-9680549
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-96805492022-12-02 Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease Oyama-Manabe, Noriko Aikawa, Tadao Tsuneta, Satonori Manabe, Osamu Magn Reson Med Sci Review 4D flow MRI allows time-resolved 3D velocity-encoded phase-contrast imaging for 3D visualization and quantification of aortic and intracardiac flow. Radiologists should be familiar with the principles of 4D flow MRI and methods for evaluating blood flow qualitatively and quantitatively. The most substantial benefits of 4D flow MRI are that it enables the simultaneous comprehensive assessment of different vessels, and that retrospective analysis can be achieved in all vessels in any direction in the field of view, which is especially beneficial for patients with complicated congenital heart disease (CHD). For aortic valvular diseases, new parameters such as wall shear stress and energy loss may provide new prognostic values for 4D flow MRI. In this review, we introduce the clinical applications of 4D flow MRI for the visualization of blood flow and quantification of hemodynamic metrics in the setting of aortic valvular disease and CHD, including intracardiac shunt and coronary artery anomaly. Japanese Society for Magnetic Resonance in Medicine 2021-06-25 /pmc/articles/PMC9680549/ /pubmed/34176866 http://dx.doi.org/10.2463/mrms.rev.2021-0030 Text en ©2021 Japanese Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Review
Oyama-Manabe, Noriko
Aikawa, Tadao
Tsuneta, Satonori
Manabe, Osamu
Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease
title Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease
title_full Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease
title_fullStr Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease
title_full_unstemmed Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease
title_short Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease
title_sort clinical applications of 4d flow mr imaging in aortic valvular and congenital heart disease
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680549/
https://www.ncbi.nlm.nih.gov/pubmed/34176866
http://dx.doi.org/10.2463/mrms.rev.2021-0030
work_keys_str_mv AT oyamamanabenoriko clinicalapplicationsof4dflowmrimaginginaorticvalvularandcongenitalheartdisease
AT aikawatadao clinicalapplicationsof4dflowmrimaginginaorticvalvularandcongenitalheartdisease
AT tsunetasatonori clinicalapplicationsof4dflowmrimaginginaorticvalvularandcongenitalheartdisease
AT manabeosamu clinicalapplicationsof4dflowmrimaginginaorticvalvularandcongenitalheartdisease