Cargando…

Clinical Applications of 4D Flow MRI in the Portal Venous System

Evaluation of the hemodynamics in the portal venous system plays an essential role in many hepatic pathologies. Changes in portal flow and vessel morphology are often indicative of disease.Routinely used imaging modalities, such as CT, ultrasound, invasive angiography, and MRI, often focus on either...

Descripción completa

Detalles Bibliográficos
Autores principales: Oechtering, Thekla H., Roberts, Grant S., Panagiotopoulos, Nikolaos, Wieben, Oliver, Reeder, Scott B., Roldán-Alzate, Alejandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680553/
https://www.ncbi.nlm.nih.gov/pubmed/35082218
http://dx.doi.org/10.2463/mrms.rev.2021-0105
_version_ 1784834445469024256
author Oechtering, Thekla H.
Roberts, Grant S.
Panagiotopoulos, Nikolaos
Wieben, Oliver
Reeder, Scott B.
Roldán-Alzate, Alejandro
author_facet Oechtering, Thekla H.
Roberts, Grant S.
Panagiotopoulos, Nikolaos
Wieben, Oliver
Reeder, Scott B.
Roldán-Alzate, Alejandro
author_sort Oechtering, Thekla H.
collection PubMed
description Evaluation of the hemodynamics in the portal venous system plays an essential role in many hepatic pathologies. Changes in portal flow and vessel morphology are often indicative of disease.Routinely used imaging modalities, such as CT, ultrasound, invasive angiography, and MRI, often focus on either hemodynamics or anatomical imaging. In contrast, 4D flow MRI facilitiates a more comprehensive understanding of pathophysiological mechanisms by simultaneously and noninvasively acquiring time-resolved flow and anatomical information in a 3D imaging volume. Though promising, 4D flow MRI in the portal venous system is especially challenging due to small vessel calibers, slow flow velocities, and breathing motion. In this review article, we will discuss how to account for these challenges when planning and conducting 4D flow MRI acquisitions in the upper abdomen. We will address patient preparation, sequence acquisition, postprocessing, quality control, and analysis of 4D flow data. In the second part of this article, we will review potential clinical applications of 4D flow MRI in the portal venous system. The most promising area for clinical utilization is the diagnosis and grading of liver cirrhosis and its complications. Relevant parameters acquired by 4D flow MRI include the detection of reduced or reversed flow in the portal venous system, characterization of portosystemic collaterals, and impaired response to a meal challenge. In patients with cirrhosis, 4D flow MRI has the potential to address the major unmet need of noninvasive detection of gastroesophageal varices at high risk for bleeding. This could replace many unnecessary, purely diagnostic, and invasive esophagogastroduodenoscopy procedures, thereby improving patient compliance with follow-up. Moreover, 4D flow MRI offers unique insights and added value for surgical planning and follow-up of multiple hepatic interventions, including transjugular intrahepatic portosystemic shunts, liver transplantation, and hepatic disease in children. Lastly, we will discuss the path to clinical implementation and remaining challenges.
format Online
Article
Text
id pubmed-9680553
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-96805532022-12-02 Clinical Applications of 4D Flow MRI in the Portal Venous System Oechtering, Thekla H. Roberts, Grant S. Panagiotopoulos, Nikolaos Wieben, Oliver Reeder, Scott B. Roldán-Alzate, Alejandro Magn Reson Med Sci Review Evaluation of the hemodynamics in the portal venous system plays an essential role in many hepatic pathologies. Changes in portal flow and vessel morphology are often indicative of disease.Routinely used imaging modalities, such as CT, ultrasound, invasive angiography, and MRI, often focus on either hemodynamics or anatomical imaging. In contrast, 4D flow MRI facilitiates a more comprehensive understanding of pathophysiological mechanisms by simultaneously and noninvasively acquiring time-resolved flow and anatomical information in a 3D imaging volume. Though promising, 4D flow MRI in the portal venous system is especially challenging due to small vessel calibers, slow flow velocities, and breathing motion. In this review article, we will discuss how to account for these challenges when planning and conducting 4D flow MRI acquisitions in the upper abdomen. We will address patient preparation, sequence acquisition, postprocessing, quality control, and analysis of 4D flow data. In the second part of this article, we will review potential clinical applications of 4D flow MRI in the portal venous system. The most promising area for clinical utilization is the diagnosis and grading of liver cirrhosis and its complications. Relevant parameters acquired by 4D flow MRI include the detection of reduced or reversed flow in the portal venous system, characterization of portosystemic collaterals, and impaired response to a meal challenge. In patients with cirrhosis, 4D flow MRI has the potential to address the major unmet need of noninvasive detection of gastroesophageal varices at high risk for bleeding. This could replace many unnecessary, purely diagnostic, and invasive esophagogastroduodenoscopy procedures, thereby improving patient compliance with follow-up. Moreover, 4D flow MRI offers unique insights and added value for surgical planning and follow-up of multiple hepatic interventions, including transjugular intrahepatic portosystemic shunts, liver transplantation, and hepatic disease in children. Lastly, we will discuss the path to clinical implementation and remaining challenges. Japanese Society for Magnetic Resonance in Medicine 2022-01-25 /pmc/articles/PMC9680553/ /pubmed/35082218 http://dx.doi.org/10.2463/mrms.rev.2021-0105 Text en ©2022 Japanese Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Review
Oechtering, Thekla H.
Roberts, Grant S.
Panagiotopoulos, Nikolaos
Wieben, Oliver
Reeder, Scott B.
Roldán-Alzate, Alejandro
Clinical Applications of 4D Flow MRI in the Portal Venous System
title Clinical Applications of 4D Flow MRI in the Portal Venous System
title_full Clinical Applications of 4D Flow MRI in the Portal Venous System
title_fullStr Clinical Applications of 4D Flow MRI in the Portal Venous System
title_full_unstemmed Clinical Applications of 4D Flow MRI in the Portal Venous System
title_short Clinical Applications of 4D Flow MRI in the Portal Venous System
title_sort clinical applications of 4d flow mri in the portal venous system
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680553/
https://www.ncbi.nlm.nih.gov/pubmed/35082218
http://dx.doi.org/10.2463/mrms.rev.2021-0105
work_keys_str_mv AT oechteringtheklah clinicalapplicationsof4dflowmriintheportalvenoussystem
AT robertsgrants clinicalapplicationsof4dflowmriintheportalvenoussystem
AT panagiotopoulosnikolaos clinicalapplicationsof4dflowmriintheportalvenoussystem
AT wiebenoliver clinicalapplicationsof4dflowmriintheportalvenoussystem
AT reederscottb clinicalapplicationsof4dflowmriintheportalvenoussystem
AT roldanalzatealejandro clinicalapplicationsof4dflowmriintheportalvenoussystem