Cargando…

Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions

PURPOSE: To automate the generation of region‐of‐interest (ROI) apertures for use with megavoltage imaging for online positional corrections during cranial stereotactic radiosurgery. MATERIALS AND METHODS: Digitally reconstructed radiographs (DRRs) were created for a 3D‐printed skull phantom at 5 de...

Descripción completa

Detalles Bibliográficos
Autores principales: Church, Cody, Parsons, David, Syme, Alasdair
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680576/
https://www.ncbi.nlm.nih.gov/pubmed/36052995
http://dx.doi.org/10.1002/acm2.13769
_version_ 1784834450642698240
author Church, Cody
Parsons, David
Syme, Alasdair
author_facet Church, Cody
Parsons, David
Syme, Alasdair
author_sort Church, Cody
collection PubMed
description PURPOSE: To automate the generation of region‐of‐interest (ROI) apertures for use with megavoltage imaging for online positional corrections during cranial stereotactic radiosurgery. MATERIALS AND METHODS: Digitally reconstructed radiographs (DRRs) were created for a 3D‐printed skull phantom at 5 degree gantry angle increments for a three‐arc beam arrangement. At each angle, 3000 random rectangular apertures were generated, and 100 shifts on a grid were applied to the anatomy within the frame. For all shifts, the mutual information (MI) between the shifted and unshifted DRR was calculated to derive an average MI gradient. The top 10% of apertures that minimized registration errors were overlaid and discretely thresholded to generate imaging plans. Imaging was acquired with the skull while implementing simulated patient motion on a linac. Control point‐specific couch motions were derived to align the skull to its planned positioning. RESULTS: Apertures with a range of repositioning errors less than 0.1 mm possessed a 42% larger average MI gradient when compared with apertures with a range greater than 1 mm. Dose calculations with Monte Carlo exhibited an 84% reduction in the dose received by 50% of the skull with the 50% thresholded plan when compared to a constant 22 × 22 cm(2) imaging plan. For all different imaging plans (with and without motion), the calculated median 3D‐errors with respect to the tracking of a metal‐BB fiducial positioned at isocenter in the skull were sub‐mm except for the 80% thresholded plan. CONCLUSIONS: Sub‐mm positional errors are achievable with couch motions derived from control point–specific ROI imaging. Smaller apertures that conform to an anatomical ROI can be utilized to minimize the imaging dose incurred at the expense of larger errors.
format Online
Article
Text
id pubmed-9680576
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-96805762022-11-23 Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions Church, Cody Parsons, David Syme, Alasdair J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To automate the generation of region‐of‐interest (ROI) apertures for use with megavoltage imaging for online positional corrections during cranial stereotactic radiosurgery. MATERIALS AND METHODS: Digitally reconstructed radiographs (DRRs) were created for a 3D‐printed skull phantom at 5 degree gantry angle increments for a three‐arc beam arrangement. At each angle, 3000 random rectangular apertures were generated, and 100 shifts on a grid were applied to the anatomy within the frame. For all shifts, the mutual information (MI) between the shifted and unshifted DRR was calculated to derive an average MI gradient. The top 10% of apertures that minimized registration errors were overlaid and discretely thresholded to generate imaging plans. Imaging was acquired with the skull while implementing simulated patient motion on a linac. Control point‐specific couch motions were derived to align the skull to its planned positioning. RESULTS: Apertures with a range of repositioning errors less than 0.1 mm possessed a 42% larger average MI gradient when compared with apertures with a range greater than 1 mm. Dose calculations with Monte Carlo exhibited an 84% reduction in the dose received by 50% of the skull with the 50% thresholded plan when compared to a constant 22 × 22 cm(2) imaging plan. For all different imaging plans (with and without motion), the calculated median 3D‐errors with respect to the tracking of a metal‐BB fiducial positioned at isocenter in the skull were sub‐mm except for the 80% thresholded plan. CONCLUSIONS: Sub‐mm positional errors are achievable with couch motions derived from control point–specific ROI imaging. Smaller apertures that conform to an anatomical ROI can be utilized to minimize the imaging dose incurred at the expense of larger errors. John Wiley and Sons Inc. 2022-09-02 /pmc/articles/PMC9680576/ /pubmed/36052995 http://dx.doi.org/10.1002/acm2.13769 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Church, Cody
Parsons, David
Syme, Alasdair
Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions
title Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions
title_full Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions
title_fullStr Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions
title_full_unstemmed Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions
title_short Region‐of‐interest intra‐arc MV imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions
title_sort region‐of‐interest intra‐arc mv imaging to facilitate sub‐mm positional accuracy with minimal imaging dose during treatment deliveries of small cranial lesions
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680576/
https://www.ncbi.nlm.nih.gov/pubmed/36052995
http://dx.doi.org/10.1002/acm2.13769
work_keys_str_mv AT churchcody regionofinterestintraarcmvimagingtofacilitatesubmmpositionalaccuracywithminimalimagingdoseduringtreatmentdeliveriesofsmallcraniallesions
AT parsonsdavid regionofinterestintraarcmvimagingtofacilitatesubmmpositionalaccuracywithminimalimagingdoseduringtreatmentdeliveriesofsmallcraniallesions
AT symealasdair regionofinterestintraarcmvimagingtofacilitatesubmmpositionalaccuracywithminimalimagingdoseduringtreatmentdeliveriesofsmallcraniallesions