Cargando…
A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study
BACKGROUND: Although glass-ionomer cement (GIC) has many unique properties and advantages, it still lacks favorable mechanical properties. Cention N is a recent alkasite material with excellent mechanical properties. The purpose of this study was to compare the mechanical properties (fracture toughn...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680696/ https://www.ncbi.nlm.nih.gov/pubmed/36426277 |
_version_ | 1784834468882677760 |
---|---|
author | Battula, Madhuri Sai Kaushik, Mamta Mehra, Neha Raj, Vishnu |
author_facet | Battula, Madhuri Sai Kaushik, Mamta Mehra, Neha Raj, Vishnu |
author_sort | Battula, Madhuri Sai |
collection | PubMed |
description | BACKGROUND: Although glass-ionomer cement (GIC) has many unique properties and advantages, it still lacks favorable mechanical properties. Cention N is a recent alkasite material with excellent mechanical properties. The purpose of this study was to compare the mechanical properties (fracture toughness [FT] and flexural strength [FS]) and acid buffer capability of an alkasite material to GIC. MATERIALS AND METHODS: In this in vitro study, a total of 60 samples were prepared using Cention N or GIC. Twenty specimens (n = 10) were prepared using beam-shaped Teflon molds for FS, and twenty specimens (n = 10) were prepared with a similar mold with a notch for FT. These were evaluated on a universal testing machine using a three-point bend test. Twenty (n = 10) disk-shaped specimens were prepared for acid buffer capability. The samples were stored in distilled water for a week. This was followed by immersion in lactic acid with a pH of 4 for calculation of the materials acid buffering capacity at 30 and 60 min from exposure using a pH meter. The data obtained were tabulated and subjected to Kolmogorov–Smirnov test and Shapiro–Wilk test to assess the normal distribution and further analyzed using the Student’s t-test to assess the level of significance, P < 0.05 was considered statistically significant. RESULTS: The mean FT, FS, and acid buffer capability of Cention N were significantly higher than GIC at P < 0.05. CONCLUSION: The present study surmised that Cention N exhibited higher FT, FS, and acid buffer capability than GIC. |
format | Online Article Text |
id | pubmed-9680696 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-96806962022-11-23 A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study Battula, Madhuri Sai Kaushik, Mamta Mehra, Neha Raj, Vishnu Dent Res J (Isfahan) Original Article BACKGROUND: Although glass-ionomer cement (GIC) has many unique properties and advantages, it still lacks favorable mechanical properties. Cention N is a recent alkasite material with excellent mechanical properties. The purpose of this study was to compare the mechanical properties (fracture toughness [FT] and flexural strength [FS]) and acid buffer capability of an alkasite material to GIC. MATERIALS AND METHODS: In this in vitro study, a total of 60 samples were prepared using Cention N or GIC. Twenty specimens (n = 10) were prepared using beam-shaped Teflon molds for FS, and twenty specimens (n = 10) were prepared with a similar mold with a notch for FT. These were evaluated on a universal testing machine using a three-point bend test. Twenty (n = 10) disk-shaped specimens were prepared for acid buffer capability. The samples were stored in distilled water for a week. This was followed by immersion in lactic acid with a pH of 4 for calculation of the materials acid buffering capacity at 30 and 60 min from exposure using a pH meter. The data obtained were tabulated and subjected to Kolmogorov–Smirnov test and Shapiro–Wilk test to assess the normal distribution and further analyzed using the Student’s t-test to assess the level of significance, P < 0.05 was considered statistically significant. RESULTS: The mean FT, FS, and acid buffer capability of Cention N were significantly higher than GIC at P < 0.05. CONCLUSION: The present study surmised that Cention N exhibited higher FT, FS, and acid buffer capability than GIC. Wolters Kluwer - Medknow 2022-10-20 /pmc/articles/PMC9680696/ /pubmed/36426277 Text en Copyright: © 2022 Dental Research Journal https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Battula, Madhuri Sai Kaushik, Mamta Mehra, Neha Raj, Vishnu A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study |
title | A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study |
title_full | A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study |
title_fullStr | A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study |
title_full_unstemmed | A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study |
title_short | A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study |
title_sort | comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680696/ https://www.ncbi.nlm.nih.gov/pubmed/36426277 |
work_keys_str_mv | AT battulamadhurisai acomparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy AT kaushikmamta acomparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy AT mehraneha acomparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy AT rajvishnu acomparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy AT battulamadhurisai comparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy AT kaushikmamta comparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy AT mehraneha comparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy AT rajvishnu comparativeevaluationoffracturetoughnessflexuralstrengthandacidbuffercapabilityofabulkfillalkasitewithhighstrengthglassionomercementaninvitrostudy |