Cargando…

Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning

BACKGROUND: Contrast‐enhanced magnetic resonance angiography (MRA) is used to assess various cardiovascular conditions. However, gadolinium‐based contrast agents (GBCAs) carry a risk of dose‐related adverse effects. PURPOSE: To develop a deep learning method to reduce GBCA dose by 80%. STUDY TYPE: R...

Descripción completa

Detalles Bibliográficos
Autores principales: Montalt‐Tordera, Javier, Quail, Michael, Steeden, Jennifer A, Muthurangu, Vivek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9681557/
https://www.ncbi.nlm.nih.gov/pubmed/33619859
http://dx.doi.org/10.1002/jmri.27573
_version_ 1784834645591851008
author Montalt‐Tordera, Javier
Quail, Michael
Steeden, Jennifer A
Muthurangu, Vivek
author_facet Montalt‐Tordera, Javier
Quail, Michael
Steeden, Jennifer A
Muthurangu, Vivek
author_sort Montalt‐Tordera, Javier
collection PubMed
description BACKGROUND: Contrast‐enhanced magnetic resonance angiography (MRA) is used to assess various cardiovascular conditions. However, gadolinium‐based contrast agents (GBCAs) carry a risk of dose‐related adverse effects. PURPOSE: To develop a deep learning method to reduce GBCA dose by 80%. STUDY TYPE: Retrospective and prospective. POPULATION: A total of 1157 retrospective and 40 prospective congenital heart disease patients for training/validation and testing, respectively. FIELD STRENGTH/SEQUENCE: A 1.5 T, T1‐weighted three‐dimensional (3D) gradient echo. ASSESSMENT: A neural network was trained to enhance low‐dose (LD) 3D MRA using retrospective synthetic data and tested with prospective LD data. Image quality for LD (LD‐MRA), enhanced LD (ELD‐MRA), and high‐dose (HD‐MRA) was assessed in terms of signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and a quantitative measure of edge sharpness and scored for perceptual sharpness and contrast on a 1–5 scale. Diagnostic confidence was assessed on a 1–3 scale. LD‐ and ELD‐MRA were assessed against HD‐MRA for sensitivity/specificity and agreement of vessel diameter measurements (aorta and pulmonary arteries). STATISTICAL TESTS: SNR, CNR, edge sharpness, and vessel diameters were compared between LD‐, ELD‐, and HD‐MRA using one‐way repeated measures analysis of variance with post‐hoc t‐tests. Perceptual quality and diagnostic confidence were compared using Friedman's test with post‐hoc Wilcoxon signed‐rank tests. Sensitivity/specificity was compared using McNemar's test. Agreement of vessel diameters was assessed using Bland–Altman analysis. RESULTS: SNR, CNR, edge sharpness, perceptual sharpness, and perceptual contrast were lower (P < 0.05) for LD‐MRA compared to ELD‐MRA and HD‐MRA. SNR, CNR, edge sharpness, and perceptual contrast were comparable between ELD and HD‐MRA, but perceptual sharpness was significantly lower. Sensitivity/specificity was 0.824/0.921 for LD‐MRA and 0.882/0.960 for ELD‐MRA. Diagnostic confidence was 2.72, 2.85, and 2.92 for LD, ELD, and HD‐MRA, respectively (P (LD‐ELD), P (LD‐HD) < 0.05). Vessel diameter measurements were comparable, with biases of 0.238 (LD‐MRA) and 0.278 mm (ELD‐MRA). DATA CONCLUSION: Deep learning can improve contrast in LD cardiovascular MRA. LEVEL OF EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2
format Online
Article
Text
id pubmed-9681557
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-96815572022-11-25 Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning Montalt‐Tordera, Javier Quail, Michael Steeden, Jennifer A Muthurangu, Vivek J Magn Reson Imaging Research Articles BACKGROUND: Contrast‐enhanced magnetic resonance angiography (MRA) is used to assess various cardiovascular conditions. However, gadolinium‐based contrast agents (GBCAs) carry a risk of dose‐related adverse effects. PURPOSE: To develop a deep learning method to reduce GBCA dose by 80%. STUDY TYPE: Retrospective and prospective. POPULATION: A total of 1157 retrospective and 40 prospective congenital heart disease patients for training/validation and testing, respectively. FIELD STRENGTH/SEQUENCE: A 1.5 T, T1‐weighted three‐dimensional (3D) gradient echo. ASSESSMENT: A neural network was trained to enhance low‐dose (LD) 3D MRA using retrospective synthetic data and tested with prospective LD data. Image quality for LD (LD‐MRA), enhanced LD (ELD‐MRA), and high‐dose (HD‐MRA) was assessed in terms of signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and a quantitative measure of edge sharpness and scored for perceptual sharpness and contrast on a 1–5 scale. Diagnostic confidence was assessed on a 1–3 scale. LD‐ and ELD‐MRA were assessed against HD‐MRA for sensitivity/specificity and agreement of vessel diameter measurements (aorta and pulmonary arteries). STATISTICAL TESTS: SNR, CNR, edge sharpness, and vessel diameters were compared between LD‐, ELD‐, and HD‐MRA using one‐way repeated measures analysis of variance with post‐hoc t‐tests. Perceptual quality and diagnostic confidence were compared using Friedman's test with post‐hoc Wilcoxon signed‐rank tests. Sensitivity/specificity was compared using McNemar's test. Agreement of vessel diameters was assessed using Bland–Altman analysis. RESULTS: SNR, CNR, edge sharpness, perceptual sharpness, and perceptual contrast were lower (P < 0.05) for LD‐MRA compared to ELD‐MRA and HD‐MRA. SNR, CNR, edge sharpness, and perceptual contrast were comparable between ELD and HD‐MRA, but perceptual sharpness was significantly lower. Sensitivity/specificity was 0.824/0.921 for LD‐MRA and 0.882/0.960 for ELD‐MRA. Diagnostic confidence was 2.72, 2.85, and 2.92 for LD, ELD, and HD‐MRA, respectively (P (LD‐ELD), P (LD‐HD) < 0.05). Vessel diameter measurements were comparable, with biases of 0.238 (LD‐MRA) and 0.278 mm (ELD‐MRA). DATA CONCLUSION: Deep learning can improve contrast in LD cardiovascular MRA. LEVEL OF EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2 John Wiley & Sons, Inc. 2021-02-22 2021-09 /pmc/articles/PMC9681557/ /pubmed/33619859 http://dx.doi.org/10.1002/jmri.27573 Text en © 2021 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC. on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Montalt‐Tordera, Javier
Quail, Michael
Steeden, Jennifer A
Muthurangu, Vivek
Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning
title Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning
title_full Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning
title_fullStr Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning
title_full_unstemmed Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning
title_short Reducing Contrast Agent Dose in Cardiovascular MR Angiography with Deep Learning
title_sort reducing contrast agent dose in cardiovascular mr angiography with deep learning
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9681557/
https://www.ncbi.nlm.nih.gov/pubmed/33619859
http://dx.doi.org/10.1002/jmri.27573
work_keys_str_mv AT montalttorderajavier reducingcontrastagentdoseincardiovascularmrangiographywithdeeplearning
AT quailmichael reducingcontrastagentdoseincardiovascularmrangiographywithdeeplearning
AT steedenjennifera reducingcontrastagentdoseincardiovascularmrangiographywithdeeplearning
AT muthuranguvivek reducingcontrastagentdoseincardiovascularmrangiographywithdeeplearning