Cargando…
First-in-man application of Liwen RF™ ablation system in the treatment of drug-resistant hypertrophic obstructive cardiomyopathy
OBJECTIVES: This study sought to evaluate the clinical applicability of the Liwen Liu RF™ ablation system for percutaneous intramyocardial septal radiofrequency ablation (PIMSRA). BACKGROUND: Data on new cardiac radiofrequency ablation devices for the treatment of hypertrophic obstructive cardiomyop...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9681805/ https://www.ncbi.nlm.nih.gov/pubmed/36440055 http://dx.doi.org/10.3389/fcvm.2022.1028763 |
Sumario: | OBJECTIVES: This study sought to evaluate the clinical applicability of the Liwen Liu RF™ ablation system for percutaneous intramyocardial septal radiofrequency ablation (PIMSRA). BACKGROUND: Data on new cardiac radiofrequency ablation devices for the treatment of hypertrophic obstructive cardiomyopathy (HOCM) are limited. MATERIALS AND METHODS: From July 2019 to July 2020, a total of 68 patients with drug-resistant HOCM, who underwent PIMSRA with the Liwen RF™ ablation system, which has an ablation electrode of stepless adjustable length, were prospectively enrolled. Safety endpoints included, amongst others, the occurrence of pericardial effusion and/or hemorrhage, cardiac arrhythmias, device failure and procedural death. The reduction in left ventricular outflow tract (LVOT) gradients at 12 months follow-up were used as a surrogate marker for device efficacy. RESULTS: All procedures were technically successful. The total energy output time of the system was 75.8 (IQR: 30.0) min, and the average power was 43.61 ± 13.34 watts. No ablation system error occurred. The incidence of pericardial effusion or hemorrhage, transient arrhythmia and resuscitation was 8.8, 39.7, and 1.5% during procedure, respectively. None of the patients died. During 30-day follow-up, there were no complications with the exception of a pericardial effusion in one patient (1.5%). No further complications were reported after 30 days. The patients’ resting [baseline: 75 (IQR: 48) vs. 12-months: 12 (IQR: 19) mmHg, p < 0.001] and provoked [baseline: 122 (IQR: 53) vs. 12-months: 41 (IQR: 59) mmHg, p < 0.001] LVOT gradients decreased significantly during follow-up. CONCLUSION: In this study, we demonstrate the safety and feasibility of the Liwen RF™ ablation system to treat HOCM. The system allows for significant and sustainable LVOT gradient reduction during 12-months of follow-up. Hence, the Liwen RF™ ablation system is a promising new device that has the potential to become an alternative to existing septal reduction concepts in HOCM patients. |
---|