Cargando…

Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies

Surface modified microspheres have been leveraged as a useful way to immobilize antigen for serological studies. The use of carboxyl modified microspheres for this purpose is well-established, but commonly associated with technical challenges. Streptavidin modified microspheres require little techni...

Descripción completa

Detalles Bibliográficos
Autores principales: Whitley, Caleb S., Mitchell, Thomas C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Biological Methods 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9682163/
https://www.ncbi.nlm.nih.gov/pubmed/36438426
http://dx.doi.org/10.14440/jbm.2022.390
_version_ 1784834788815798272
author Whitley, Caleb S.
Mitchell, Thomas C.
author_facet Whitley, Caleb S.
Mitchell, Thomas C.
author_sort Whitley, Caleb S.
collection PubMed
description Surface modified microspheres have been leveraged as a useful way to immobilize antigen for serological studies. The use of carboxyl modified microspheres for this purpose is well-established, but commonly associated with technical challenges. Streptavidin modified microspheres require little technical expertise and thus address some of the shortcomings of carboxyl microspheres. An additional feature of streptavidin microspheres is the use of mono-biotinylated proteins, which contain a single biotinylation motif at the C-terminus. However, the relative performance of streptavidin and carboxyl microspheres is unknown. Here, we performed a head-to-head comparison of streptavidin and carboxyl microspheres. We compared antigen binding, orientation, and staining quality and found that both microspheres perform similarly based on these defined parameters. We also evaluated the utility of streptavidin microspheres bound to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) receptor binding domain (RBD), to reliably detect RBD-specific IgG1, IgG3, and IgA1 produced in individuals recently immunized with Pfizer/BioNTech mRNA coronavirus disease (COVID) vaccine as ‘proof-of-concept’. We provide evidence that each of the antibody targets are detectable in serum using RBD-coated microspheres, Ig-specific ‘detector’ monoclonal antibodies (mAbs), and flow cytometry. We found that cross-reactivity of the detector mAbs can be minimized by antibody titration to improve differentiation between IgG1 and IgG3. We also coated streptavidin microspheres with SARS-CoV-2 delta variant RBD to determine if the streptavidin microsphere approach revealed any differences in binding of immune serum antibodies to wild-type (Wuhan) versus variant RBD (Delta). Overall, our results show that streptavidin microspheres loaded with mono-biotinylated antigen is a robust alternative to chemically cross-linking antigen to carboxyl microspheres for use in serological assays.
format Online
Article
Text
id pubmed-9682163
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Journal of Biological Methods
record_format MEDLINE/PubMed
spelling pubmed-96821632022-11-24 Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies Whitley, Caleb S. Mitchell, Thomas C. J Biol Methods Article Surface modified microspheres have been leveraged as a useful way to immobilize antigen for serological studies. The use of carboxyl modified microspheres for this purpose is well-established, but commonly associated with technical challenges. Streptavidin modified microspheres require little technical expertise and thus address some of the shortcomings of carboxyl microspheres. An additional feature of streptavidin microspheres is the use of mono-biotinylated proteins, which contain a single biotinylation motif at the C-terminus. However, the relative performance of streptavidin and carboxyl microspheres is unknown. Here, we performed a head-to-head comparison of streptavidin and carboxyl microspheres. We compared antigen binding, orientation, and staining quality and found that both microspheres perform similarly based on these defined parameters. We also evaluated the utility of streptavidin microspheres bound to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) receptor binding domain (RBD), to reliably detect RBD-specific IgG1, IgG3, and IgA1 produced in individuals recently immunized with Pfizer/BioNTech mRNA coronavirus disease (COVID) vaccine as ‘proof-of-concept’. We provide evidence that each of the antibody targets are detectable in serum using RBD-coated microspheres, Ig-specific ‘detector’ monoclonal antibodies (mAbs), and flow cytometry. We found that cross-reactivity of the detector mAbs can be minimized by antibody titration to improve differentiation between IgG1 and IgG3. We also coated streptavidin microspheres with SARS-CoV-2 delta variant RBD to determine if the streptavidin microsphere approach revealed any differences in binding of immune serum antibodies to wild-type (Wuhan) versus variant RBD (Delta). Overall, our results show that streptavidin microspheres loaded with mono-biotinylated antigen is a robust alternative to chemically cross-linking antigen to carboxyl microspheres for use in serological assays. Journal of Biological Methods 2022-09-23 /pmc/articles/PMC9682163/ /pubmed/36438426 http://dx.doi.org/10.14440/jbm.2022.390 Text en © 2013-2021 The Journal of Biological Methods, All rights reserved. https://creativecommons.org/licenses/by-nc-sa/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License: http://creativecommons.org/licenses/by-nc-sa/4.0
spellingShingle Article
Whitley, Caleb S.
Mitchell, Thomas C.
Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies
title Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies
title_full Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies
title_fullStr Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies
title_full_unstemmed Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies
title_short Monobiotinylated Proteins Tethered to Microspheres for Detection of Antigen-Specific Serum Antibodies
title_sort monobiotinylated proteins tethered to microspheres for detection of antigen-specific serum antibodies
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9682163/
https://www.ncbi.nlm.nih.gov/pubmed/36438426
http://dx.doi.org/10.14440/jbm.2022.390
work_keys_str_mv AT whitleycalebs monobiotinylatedproteinstetheredtomicrospheresfordetectionofantigenspecificserumantibodies
AT mitchellthomasc monobiotinylatedproteinstetheredtomicrospheresfordetectionofantigenspecificserumantibodies