Cargando…
Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature
INTRODUCTION: Surgical tracheostomy (ST) and Percutaneous dilatational tracheostomy (PDT) are classified as high-risk aerosol-generating procedures and might lead to healthcare workers (HCW) infection. Albeit the COVID-19 strain slightly released since the vaccination era, preventing HCW from infect...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9683587/ https://www.ncbi.nlm.nih.gov/pubmed/36417482 http://dx.doi.org/10.1371/journal.pone.0278089 |
_version_ | 1784835083459362816 |
---|---|
author | Favier, Valentin Lescroart, Mickael Pequignot, Benjamin Grimmer, Léonie Florentin, Arnaud Gallet, Patrice |
author_facet | Favier, Valentin Lescroart, Mickael Pequignot, Benjamin Grimmer, Léonie Florentin, Arnaud Gallet, Patrice |
author_sort | Favier, Valentin |
collection | PubMed |
description | INTRODUCTION: Surgical tracheostomy (ST) and Percutaneous dilatational tracheostomy (PDT) are classified as high-risk aerosol-generating procedures and might lead to healthcare workers (HCW) infection. Albeit the COVID-19 strain slightly released since the vaccination era, preventing HCW from infection remains a major economical and medical concern. To date, there is no study monitoring particle emissions during ST and PDT in a clinical setting. The aim of this study was to monitor particle emissions during ST and PDT in a swine model. METHODS: A randomized animal study on swine model with induced acute respiratory distress syndrome (ARDS) was conducted. A dedicated room with controlled airflow was used to standardize the measurements obtained using an airborne optical particle counter. 6 ST and 6 PDT were performed in 12 pigs. Airborne particles (diameter of 0.5 to 3 μm) were continuously measured; video and audio data were recorded. The emission of particles was considered as significant if the number of particles increased beyond the normal variations of baseline particle contamination determinations in the room. These significant emissions were interpreted in the light of video and audio recordings. Duration of procedures, number of expiratory pauses, technical errors and adverse events were also analyzed. RESULTS: 10 procedures (5 ST and 5 PDT) were fully analyzable. There was no systematic aerosolization during procedures. However, in 1/5 ST and 4/5 PDT, minor leaks and some adverse events (cuff perforation in 1 ST and 1 PDT) occurred. Human factors were responsible for 1 aerosolization during 1 PDT procedure. ST duration was significantly shorter than PDT (8.6 ± 1.3 vs 15.6 ± 1.9 minutes) and required less expiratory pauses (1 vs 6.8 ± 1.2). CONCLUSIONS: COVID-19 adaptations allow preventing for major aerosol leaks for both ST and PDT, contributing to preserving healthcare workers during COVID-19 outbreak, but failed to achieve a perfectly airtight procedure. However, with COVID-19 adaptations, PDT required more expiratory pauses and more time than ST. Human factors and adverse events may lead to aerosolization and might be more frequent in PDT. |
format | Online Article Text |
id | pubmed-9683587 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-96835872022-11-24 Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature Favier, Valentin Lescroart, Mickael Pequignot, Benjamin Grimmer, Léonie Florentin, Arnaud Gallet, Patrice PLoS One Research Article INTRODUCTION: Surgical tracheostomy (ST) and Percutaneous dilatational tracheostomy (PDT) are classified as high-risk aerosol-generating procedures and might lead to healthcare workers (HCW) infection. Albeit the COVID-19 strain slightly released since the vaccination era, preventing HCW from infection remains a major economical and medical concern. To date, there is no study monitoring particle emissions during ST and PDT in a clinical setting. The aim of this study was to monitor particle emissions during ST and PDT in a swine model. METHODS: A randomized animal study on swine model with induced acute respiratory distress syndrome (ARDS) was conducted. A dedicated room with controlled airflow was used to standardize the measurements obtained using an airborne optical particle counter. 6 ST and 6 PDT were performed in 12 pigs. Airborne particles (diameter of 0.5 to 3 μm) were continuously measured; video and audio data were recorded. The emission of particles was considered as significant if the number of particles increased beyond the normal variations of baseline particle contamination determinations in the room. These significant emissions were interpreted in the light of video and audio recordings. Duration of procedures, number of expiratory pauses, technical errors and adverse events were also analyzed. RESULTS: 10 procedures (5 ST and 5 PDT) were fully analyzable. There was no systematic aerosolization during procedures. However, in 1/5 ST and 4/5 PDT, minor leaks and some adverse events (cuff perforation in 1 ST and 1 PDT) occurred. Human factors were responsible for 1 aerosolization during 1 PDT procedure. ST duration was significantly shorter than PDT (8.6 ± 1.3 vs 15.6 ± 1.9 minutes) and required less expiratory pauses (1 vs 6.8 ± 1.2). CONCLUSIONS: COVID-19 adaptations allow preventing for major aerosol leaks for both ST and PDT, contributing to preserving healthcare workers during COVID-19 outbreak, but failed to achieve a perfectly airtight procedure. However, with COVID-19 adaptations, PDT required more expiratory pauses and more time than ST. Human factors and adverse events may lead to aerosolization and might be more frequent in PDT. Public Library of Science 2022-11-23 /pmc/articles/PMC9683587/ /pubmed/36417482 http://dx.doi.org/10.1371/journal.pone.0278089 Text en © 2022 Favier et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Favier, Valentin Lescroart, Mickael Pequignot, Benjamin Grimmer, Léonie Florentin, Arnaud Gallet, Patrice Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature |
title | Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature |
title_full | Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature |
title_fullStr | Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature |
title_full_unstemmed | Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature |
title_short | Measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy COVID-19 adapted procedures in a swine model: Experimental report and review of literature |
title_sort | measurement of airborne particle emission during surgical and percutaneous dilatational tracheostomy covid-19 adapted procedures in a swine model: experimental report and review of literature |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9683587/ https://www.ncbi.nlm.nih.gov/pubmed/36417482 http://dx.doi.org/10.1371/journal.pone.0278089 |
work_keys_str_mv | AT faviervalentin measurementofairborneparticleemissionduringsurgicalandpercutaneousdilatationaltracheostomycovid19adaptedproceduresinaswinemodelexperimentalreportandreviewofliterature AT lescroartmickael measurementofairborneparticleemissionduringsurgicalandpercutaneousdilatationaltracheostomycovid19adaptedproceduresinaswinemodelexperimentalreportandreviewofliterature AT pequignotbenjamin measurementofairborneparticleemissionduringsurgicalandpercutaneousdilatationaltracheostomycovid19adaptedproceduresinaswinemodelexperimentalreportandreviewofliterature AT grimmerleonie measurementofairborneparticleemissionduringsurgicalandpercutaneousdilatationaltracheostomycovid19adaptedproceduresinaswinemodelexperimentalreportandreviewofliterature AT florentinarnaud measurementofairborneparticleemissionduringsurgicalandpercutaneousdilatationaltracheostomycovid19adaptedproceduresinaswinemodelexperimentalreportandreviewofliterature AT galletpatrice measurementofairborneparticleemissionduringsurgicalandpercutaneousdilatationaltracheostomycovid19adaptedproceduresinaswinemodelexperimentalreportandreviewofliterature |