Cargando…

The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic

Objective  SARS-CoV-2 can be carried by aerosols and droplets produced during dental procedures, particularly by the use of high-speed handpieces, air-water syringes, and ultrasonic scalers. High-volume evacuators (HVEs) and extraoral vacuum aspirators (EOVAs) reduce such particles. However, there i...

Descripción completa

Detalles Bibliográficos
Autores principales: Suwandi, Trijani, Nursolihati, Vidya, Sundjojo, Mikha, Widyarman, Armelia Sari
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Pvt. Ltd. 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9683881/
https://www.ncbi.nlm.nih.gov/pubmed/35016239
http://dx.doi.org/10.1055/s-0041-1739448
_version_ 1784835151487827968
author Suwandi, Trijani
Nursolihati, Vidya
Sundjojo, Mikha
Widyarman, Armelia Sari
author_facet Suwandi, Trijani
Nursolihati, Vidya
Sundjojo, Mikha
Widyarman, Armelia Sari
author_sort Suwandi, Trijani
collection PubMed
description Objective  SARS-CoV-2 can be carried by aerosols and droplets produced during dental procedures, particularly by the use of high-speed handpieces, air-water syringes, and ultrasonic scalers. High-volume evacuators (HVEs) and extraoral vacuum aspirators (EOVAs) reduce such particles. However, there is limited data on their efficacy. This study aimed to determine the efficacy of HVE and EOVA in reducing aerosols and droplets during ultrasonic scaling procedures. Materials and Methods  Three ultrasonic scaling simulations were conducted on mannequins: 1. saliva ejector (SE) was used alone (control); 2. SE was used in combination with HVE; and 3. SE was used in combination with HVE and EOVA. Paper filters were placed on the operator's and assistant's face shields and bodies, and the contamination of aerosols and droplets was measured by counting blue spots on the paper filters. Statistical Analysis  All data were analyzed for normality using the Kolmogorov–Smirnov test. The differences between each method were analyzed using a two-way ANOVA, followed by a posthoc test. The differences were considered statistically significant when p  < 0.05. Result  Using HVE and EOVA reduced aerosols and droplets better than using SE alone or SE and HVE: the posthoc test for contamination revealed a significant difference ( p  < 0.01). The assistant was subjected to greater contamination than the operator during all three ultrasonic scaling procedures. Conclusion  The usage of HVE and EOVA significantly reduced aerosols and droplets compared with using SE solely. Using these techniques together could prevent the transmission of airborne disease during dental cleanings, especially COVID-19. Further studies of aerosol-reducing devices are still needed to ensure the safety of dental workers and patients.
format Online
Article
Text
id pubmed-9683881
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format MEDLINE/PubMed
spelling pubmed-96838812022-11-24 The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic Suwandi, Trijani Nursolihati, Vidya Sundjojo, Mikha Widyarman, Armelia Sari Eur J Dent Objective  SARS-CoV-2 can be carried by aerosols and droplets produced during dental procedures, particularly by the use of high-speed handpieces, air-water syringes, and ultrasonic scalers. High-volume evacuators (HVEs) and extraoral vacuum aspirators (EOVAs) reduce such particles. However, there is limited data on their efficacy. This study aimed to determine the efficacy of HVE and EOVA in reducing aerosols and droplets during ultrasonic scaling procedures. Materials and Methods  Three ultrasonic scaling simulations were conducted on mannequins: 1. saliva ejector (SE) was used alone (control); 2. SE was used in combination with HVE; and 3. SE was used in combination with HVE and EOVA. Paper filters were placed on the operator's and assistant's face shields and bodies, and the contamination of aerosols and droplets was measured by counting blue spots on the paper filters. Statistical Analysis  All data were analyzed for normality using the Kolmogorov–Smirnov test. The differences between each method were analyzed using a two-way ANOVA, followed by a posthoc test. The differences were considered statistically significant when p  < 0.05. Result  Using HVE and EOVA reduced aerosols and droplets better than using SE alone or SE and HVE: the posthoc test for contamination revealed a significant difference ( p  < 0.01). The assistant was subjected to greater contamination than the operator during all three ultrasonic scaling procedures. Conclusion  The usage of HVE and EOVA significantly reduced aerosols and droplets compared with using SE solely. Using these techniques together could prevent the transmission of airborne disease during dental cleanings, especially COVID-19. Further studies of aerosol-reducing devices are still needed to ensure the safety of dental workers and patients. Thieme Medical and Scientific Publishers Pvt. Ltd. 2022-01-11 /pmc/articles/PMC9683881/ /pubmed/35016239 http://dx.doi.org/10.1055/s-0041-1739448 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. ( https://creativecommons.org/licenses/by/4.0/ ) https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Suwandi, Trijani
Nursolihati, Vidya
Sundjojo, Mikha
Widyarman, Armelia Sari
The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic
title The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic
title_full The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic
title_fullStr The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic
title_full_unstemmed The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic
title_short The Efficacy of High-Volume Evacuators and Extraoral Vacuum Aspirators in Reducing Aerosol and Droplet in Ultrasonic Scaling Procedures during the COVID-19 Pandemic
title_sort efficacy of high-volume evacuators and extraoral vacuum aspirators in reducing aerosol and droplet in ultrasonic scaling procedures during the covid-19 pandemic
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9683881/
https://www.ncbi.nlm.nih.gov/pubmed/35016239
http://dx.doi.org/10.1055/s-0041-1739448
work_keys_str_mv AT suwanditrijani theefficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic
AT nursolihatividya theefficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic
AT sundjojomikha theefficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic
AT widyarmanarmeliasari theefficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic
AT suwanditrijani efficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic
AT nursolihatividya efficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic
AT sundjojomikha efficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic
AT widyarmanarmeliasari efficacyofhighvolumeevacuatorsandextraoralvacuumaspiratorsinreducingaerosolanddropletinultrasonicscalingproceduresduringthecovid19pandemic