Cargando…

Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial

BACKGROUND: Patients undergoing oral and maxillofacial surgeries under general anesthesia usually require nasotracheal intubation. When presented with patients with equally patent nostrils, selection of the nostril to use for intubation is an important decision for facilitating intubation. The objec...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Li-Kuan, Zhang, Xiang, Wu, Hai-Yin, Cheng, Tong, Xiong, Guo-Li, Yang, Xu-Dong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9686091/
https://www.ncbi.nlm.nih.gov/pubmed/36424554
http://dx.doi.org/10.1186/s12871-022-01910-3
_version_ 1784835663039823872
author Wang, Li-Kuan
Zhang, Xiang
Wu, Hai-Yin
Cheng, Tong
Xiong, Guo-Li
Yang, Xu-Dong
author_facet Wang, Li-Kuan
Zhang, Xiang
Wu, Hai-Yin
Cheng, Tong
Xiong, Guo-Li
Yang, Xu-Dong
author_sort Wang, Li-Kuan
collection PubMed
description BACKGROUND: Patients undergoing oral and maxillofacial surgeries under general anesthesia usually require nasotracheal intubation. When presented with patients with equally patent nostrils, selection of the nostril to use for intubation is an important decision for facilitating intubation. The objective of this trial is to determine whether choice of nostril impacts nasotracheal intubation when using a video rigid stylet in patients undergoing oral and maxillofacial surgery. METHODS: Fifty patients scheduled for elective oral and maxillofacial surgery requiring nasotracheal intubation were randomly allocated into two groups to undergo nasotracheal intubation through the left nostril (Group L, n = 25) or the right nostril (Group R, n = 25). Intubation was performed by experienced anesthesiologists using a video rigid stylet. The primary endpoint was time to successful intubation, which was defined as the duration from when the tip of the stylet-tube assembly entered the selected nostril to when the tube entered the trachea. Secondary outcomes included: length of time for device insertion; length of time for tube insertion; total success rate; first-attempt success rate; number of intubation attempts; requirement of airway assisted maneuvers; incidence and severity of epistaxis. Intubation-related adverse events were monitored for up to postoperative 24 h. RESULTS: Median time (interquartile range) to tracheal intubation was 25.3 seconds (20.7 to 27.6) in Group L and 26.8 seconds (22.5 to 30.0) in Group R (median difference (MD) = 1.9; 95% confidence interval (CI) –1.8 to 5.7, P = 0.248). Nasotracheal intubation was successful in all patients in both groups and the first-attempt success rates in both groups were similar (Group L: 96% (24/25); Group R: 96% (24/25); relative risk (RR) 1.0; 95% CI 0.9 to 1.1; P > 0.999). No significant difference of requirement of assisted maneuvers was noted between the two groups (Group L: 36% (9/25); Group R: 28% (7/25); RR 0.8; 95% CI 0.3–1.8; P = 0.544). Furthermore, all patients showed a high quality of visualization of the glottis (Cormack and Lehane Grade I). For safety outcomes, the incidence and severity of epistaxis during intubation was comparable between the two groups. There were no significant differences between the selection of nostrils and intubation-related adverse events up to 24 h after surgery. CONCLUSIONS: When considering which nostril to use for intubation with video rigid stylet, either nostril can be used similarly. TRIAL REGISTRATION: Clinicaltrials.gov. Identifier: NCT05218590.
format Online
Article
Text
id pubmed-9686091
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-96860912022-11-25 Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial Wang, Li-Kuan Zhang, Xiang Wu, Hai-Yin Cheng, Tong Xiong, Guo-Li Yang, Xu-Dong BMC Anesthesiol Research BACKGROUND: Patients undergoing oral and maxillofacial surgeries under general anesthesia usually require nasotracheal intubation. When presented with patients with equally patent nostrils, selection of the nostril to use for intubation is an important decision for facilitating intubation. The objective of this trial is to determine whether choice of nostril impacts nasotracheal intubation when using a video rigid stylet in patients undergoing oral and maxillofacial surgery. METHODS: Fifty patients scheduled for elective oral and maxillofacial surgery requiring nasotracheal intubation were randomly allocated into two groups to undergo nasotracheal intubation through the left nostril (Group L, n = 25) or the right nostril (Group R, n = 25). Intubation was performed by experienced anesthesiologists using a video rigid stylet. The primary endpoint was time to successful intubation, which was defined as the duration from when the tip of the stylet-tube assembly entered the selected nostril to when the tube entered the trachea. Secondary outcomes included: length of time for device insertion; length of time for tube insertion; total success rate; first-attempt success rate; number of intubation attempts; requirement of airway assisted maneuvers; incidence and severity of epistaxis. Intubation-related adverse events were monitored for up to postoperative 24 h. RESULTS: Median time (interquartile range) to tracheal intubation was 25.3 seconds (20.7 to 27.6) in Group L and 26.8 seconds (22.5 to 30.0) in Group R (median difference (MD) = 1.9; 95% confidence interval (CI) –1.8 to 5.7, P = 0.248). Nasotracheal intubation was successful in all patients in both groups and the first-attempt success rates in both groups were similar (Group L: 96% (24/25); Group R: 96% (24/25); relative risk (RR) 1.0; 95% CI 0.9 to 1.1; P > 0.999). No significant difference of requirement of assisted maneuvers was noted between the two groups (Group L: 36% (9/25); Group R: 28% (7/25); RR 0.8; 95% CI 0.3–1.8; P = 0.544). Furthermore, all patients showed a high quality of visualization of the glottis (Cormack and Lehane Grade I). For safety outcomes, the incidence and severity of epistaxis during intubation was comparable between the two groups. There were no significant differences between the selection of nostrils and intubation-related adverse events up to 24 h after surgery. CONCLUSIONS: When considering which nostril to use for intubation with video rigid stylet, either nostril can be used similarly. TRIAL REGISTRATION: Clinicaltrials.gov. Identifier: NCT05218590. BioMed Central 2022-11-24 /pmc/articles/PMC9686091/ /pubmed/36424554 http://dx.doi.org/10.1186/s12871-022-01910-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wang, Li-Kuan
Zhang, Xiang
Wu, Hai-Yin
Cheng, Tong
Xiong, Guo-Li
Yang, Xu-Dong
Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial
title Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial
title_full Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial
title_fullStr Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial
title_full_unstemmed Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial
title_short Impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial
title_sort impact of choice of nostril on nasotracheal intubation when using video rigid stylet: a randomized clinical trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9686091/
https://www.ncbi.nlm.nih.gov/pubmed/36424554
http://dx.doi.org/10.1186/s12871-022-01910-3
work_keys_str_mv AT wanglikuan impactofchoiceofnostrilonnasotrachealintubationwhenusingvideorigidstyletarandomizedclinicaltrial
AT zhangxiang impactofchoiceofnostrilonnasotrachealintubationwhenusingvideorigidstyletarandomizedclinicaltrial
AT wuhaiyin impactofchoiceofnostrilonnasotrachealintubationwhenusingvideorigidstyletarandomizedclinicaltrial
AT chengtong impactofchoiceofnostrilonnasotrachealintubationwhenusingvideorigidstyletarandomizedclinicaltrial
AT xiongguoli impactofchoiceofnostrilonnasotrachealintubationwhenusingvideorigidstyletarandomizedclinicaltrial
AT yangxudong impactofchoiceofnostrilonnasotrachealintubationwhenusingvideorigidstyletarandomizedclinicaltrial