Cargando…

A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses

BACKGROUND: Several studies suggest that far-field transmission (>6 ft) explains a significant number of COVID-19 superspreading outbreaks. OBJECTIVE: Therefore, quantifying the ratio of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne...

Descripción completa

Detalles Bibliográficos
Autores principales: Parhizkar, Hooman, Fretz, Mark, Laguerre, Aurélie, Stenson, Jason, Corsi, Richard L., Van Den Wymelenberg, Kevin G., Gall, Elliott T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group US 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9686220/
https://www.ncbi.nlm.nih.gov/pubmed/36424424
http://dx.doi.org/10.1038/s41370-022-00499-6
_version_ 1784835696242982912
author Parhizkar, Hooman
Fretz, Mark
Laguerre, Aurélie
Stenson, Jason
Corsi, Richard L.
Van Den Wymelenberg, Kevin G.
Gall, Elliott T.
author_facet Parhizkar, Hooman
Fretz, Mark
Laguerre, Aurélie
Stenson, Jason
Corsi, Richard L.
Van Den Wymelenberg, Kevin G.
Gall, Elliott T.
author_sort Parhizkar, Hooman
collection PubMed
description BACKGROUND: Several studies suggest that far-field transmission (>6 ft) explains a significant number of COVID-19 superspreading outbreaks. OBJECTIVE: Therefore, quantifying the ratio of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks. METHODS: In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 0.76 m (2.5 ft), 1.52 m (5 ft), 2.28 m (7.5 ft) from the participant, as well as in the exhaust plenum of the chamber. RESULTS: We observed that 0.76 m (2.5 ft) trials had ~36–44% higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field exposure relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 0.76 m, 1.52 m, and 2.28 m were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively. SIGNIFICANCE: This study suggests that for rooms with similar airflow parameters disease transmission risk is dominated by near-field exposures for shorter event durations (e.g., initial 20–25-minutes of event) whereas far-field exposures are critical throughout the entire event and are increasingly more important for longer event durations. IMPACT STATEMENT: We offer a novel methodology for studying the fate and transport of airborne bioaerosols in indoor spaces using VOCs as unique proxies for bioaerosols. We provide evidence that real-time measurement of VOCs can be applied in settings with human subjects to estimate the concentration of bioaerosol at different distances from the emitter. We also improve upon the conventional assumption that a well-mixed room exhibits instantaneous and perfect mixing by addressing spatial distances and mixing over time. We quantitatively assessed the exposure levels to breath tracers at alternate distances and provided more insights into the changes on “near-field to far-field” ratios over time. This method can be used in future to estimate the benefits of alternate environmental conditions and occupant behaviors.
format Online
Article
Text
id pubmed-9686220
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group US
record_format MEDLINE/PubMed
spelling pubmed-96862202022-11-28 A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses Parhizkar, Hooman Fretz, Mark Laguerre, Aurélie Stenson, Jason Corsi, Richard L. Van Den Wymelenberg, Kevin G. Gall, Elliott T. J Expo Sci Environ Epidemiol Article BACKGROUND: Several studies suggest that far-field transmission (>6 ft) explains a significant number of COVID-19 superspreading outbreaks. OBJECTIVE: Therefore, quantifying the ratio of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks. METHODS: In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 0.76 m (2.5 ft), 1.52 m (5 ft), 2.28 m (7.5 ft) from the participant, as well as in the exhaust plenum of the chamber. RESULTS: We observed that 0.76 m (2.5 ft) trials had ~36–44% higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field exposure relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 0.76 m, 1.52 m, and 2.28 m were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively. SIGNIFICANCE: This study suggests that for rooms with similar airflow parameters disease transmission risk is dominated by near-field exposures for shorter event durations (e.g., initial 20–25-minutes of event) whereas far-field exposures are critical throughout the entire event and are increasingly more important for longer event durations. IMPACT STATEMENT: We offer a novel methodology for studying the fate and transport of airborne bioaerosols in indoor spaces using VOCs as unique proxies for bioaerosols. We provide evidence that real-time measurement of VOCs can be applied in settings with human subjects to estimate the concentration of bioaerosol at different distances from the emitter. We also improve upon the conventional assumption that a well-mixed room exhibits instantaneous and perfect mixing by addressing spatial distances and mixing over time. We quantitatively assessed the exposure levels to breath tracers at alternate distances and provided more insights into the changes on “near-field to far-field” ratios over time. This method can be used in future to estimate the benefits of alternate environmental conditions and occupant behaviors. Nature Publishing Group US 2022-11-23 2023 /pmc/articles/PMC9686220/ /pubmed/36424424 http://dx.doi.org/10.1038/s41370-022-00499-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Parhizkar, Hooman
Fretz, Mark
Laguerre, Aurélie
Stenson, Jason
Corsi, Richard L.
Van Den Wymelenberg, Kevin G.
Gall, Elliott T.
A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
title A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
title_full A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
title_fullStr A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
title_full_unstemmed A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
title_short A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
title_sort novel voc breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9686220/
https://www.ncbi.nlm.nih.gov/pubmed/36424424
http://dx.doi.org/10.1038/s41370-022-00499-6
work_keys_str_mv AT parhizkarhooman anovelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT fretzmark anovelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT laguerreaurelie anovelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT stensonjason anovelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT corsirichardl anovelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT vandenwymelenbergkeving anovelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT gallelliottt anovelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT parhizkarhooman novelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT fretzmark novelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT laguerreaurelie novelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT stensonjason novelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT corsirichardl novelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT vandenwymelenbergkeving novelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses
AT gallelliottt novelvocbreathtracermethodtoevaluateindoorrespiratoryexposuresinthenearandfarfieldsimplicationsforthespreadofrespiratoryviruses