Cargando…

The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach

The cyclic loading, in the corrosive medium of the human body, results in tribocorrosion at the interface of the head-neck taper junction of hip implants. The resulting metal ions and wear debris adversely affect the local tissues. The force applied by surgeons to assemble the junction has proven to...

Descripción completa

Detalles Bibliográficos
Autores principales: Fallahnezhad, Khosro, Feyzi, Mohsen, Hashemi, Reza, Taylor, Mark
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9687484/
https://www.ncbi.nlm.nih.gov/pubmed/36354540
http://dx.doi.org/10.3390/bioengineering9110629
_version_ 1784836016827269120
author Fallahnezhad, Khosro
Feyzi, Mohsen
Hashemi, Reza
Taylor, Mark
author_facet Fallahnezhad, Khosro
Feyzi, Mohsen
Hashemi, Reza
Taylor, Mark
author_sort Fallahnezhad, Khosro
collection PubMed
description The cyclic loading, in the corrosive medium of the human body, results in tribocorrosion at the interface of the head-neck taper junction of hip implants. The resulting metal ions and wear debris adversely affect the local tissues. The force applied by surgeons to assemble the junction has proven to play a major role in the mechanics of the taper junction which, in turn, can influence the tribocorrosion damage. Recently, finite element method has been used to predict the material loss at the head-neck interface. However, in most finite element studies, the contribution of electrochemical corrosion has been ignored. Therefore, a detailed study to investigate the influence of the assembly force on the tribocorrosive behaviour of the head-neck junction, which considers both the mechanical and chemical material removal, is of paramount interest. In this study, a finite-element-based algorithm was used to investigate the effect of assembly force on the tribocorrosion damage at the junction interface, for over four million cycles of simulated level gait. The patterns of the material removal in the modelling results were compared with the damage patterns observed in a group of retrieved modular hip implants. The results of this study showed that for different cases, chemical wear was in the range of 25–50% of the total material loss, after four million cycles. A minimum assembly force (4 kN for the studied cases) was needed to maintain the interlock in the junction. The computational model was able to predict the damage pattern at the retrieved head-neck interface.
format Online
Article
Text
id pubmed-9687484
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96874842022-11-25 The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach Fallahnezhad, Khosro Feyzi, Mohsen Hashemi, Reza Taylor, Mark Bioengineering (Basel) Article The cyclic loading, in the corrosive medium of the human body, results in tribocorrosion at the interface of the head-neck taper junction of hip implants. The resulting metal ions and wear debris adversely affect the local tissues. The force applied by surgeons to assemble the junction has proven to play a major role in the mechanics of the taper junction which, in turn, can influence the tribocorrosion damage. Recently, finite element method has been used to predict the material loss at the head-neck interface. However, in most finite element studies, the contribution of electrochemical corrosion has been ignored. Therefore, a detailed study to investigate the influence of the assembly force on the tribocorrosive behaviour of the head-neck junction, which considers both the mechanical and chemical material removal, is of paramount interest. In this study, a finite-element-based algorithm was used to investigate the effect of assembly force on the tribocorrosion damage at the junction interface, for over four million cycles of simulated level gait. The patterns of the material removal in the modelling results were compared with the damage patterns observed in a group of retrieved modular hip implants. The results of this study showed that for different cases, chemical wear was in the range of 25–50% of the total material loss, after four million cycles. A minimum assembly force (4 kN for the studied cases) was needed to maintain the interlock in the junction. The computational model was able to predict the damage pattern at the retrieved head-neck interface. MDPI 2022-11-01 /pmc/articles/PMC9687484/ /pubmed/36354540 http://dx.doi.org/10.3390/bioengineering9110629 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fallahnezhad, Khosro
Feyzi, Mohsen
Hashemi, Reza
Taylor, Mark
The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach
title The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach
title_full The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach
title_fullStr The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach
title_full_unstemmed The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach
title_short The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach
title_sort role of the assembly force in the tribocorrosion behaviour of hip implant head-neck junctions: an adaptive finite element approach
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9687484/
https://www.ncbi.nlm.nih.gov/pubmed/36354540
http://dx.doi.org/10.3390/bioengineering9110629
work_keys_str_mv AT fallahnezhadkhosro theroleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach
AT feyzimohsen theroleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach
AT hashemireza theroleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach
AT taylormark theroleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach
AT fallahnezhadkhosro roleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach
AT feyzimohsen roleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach
AT hashemireza roleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach
AT taylormark roleoftheassemblyforceinthetribocorrosionbehaviourofhipimplantheadneckjunctionsanadaptivefiniteelementapproach