Cargando…
Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies
Analyzing the electrical double layer (EDL) in electrical impedance spectroscopy (EIS) measurement at low frequencies remains a challenging task for sensing purposes. In this work, we propose two approaches to deal with the EDL in measuring impedance for particles and non-adherent cells in an electr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9687723/ https://www.ncbi.nlm.nih.gov/pubmed/36421098 http://dx.doi.org/10.3390/bioengineering9110697 |
_version_ | 1784836081007460352 |
---|---|
author | De León-Hernández, Alma Romero-Ornelas, Luisa Ramírez-Chavarría, Roberto G. Ramón-Gallegos, Eva Sánchez-Pérez, Celia |
author_facet | De León-Hernández, Alma Romero-Ornelas, Luisa Ramírez-Chavarría, Roberto G. Ramón-Gallegos, Eva Sánchez-Pérez, Celia |
author_sort | De León-Hernández, Alma |
collection | PubMed |
description | Analyzing the electrical double layer (EDL) in electrical impedance spectroscopy (EIS) measurement at low frequencies remains a challenging task for sensing purposes. In this work, we propose two approaches to deal with the EDL in measuring impedance for particles and non-adherent cells in an electrolytic suspension. The first approach is a simple procedure to compute a normalized electrical impedance spectrum named dispersed medium index ([Formula: see text]). The second is the EIS modeling through an equivalent electric circuit based on the so-called effective capacitance ([Formula: see text]), which unifies the EDL phenomena. Firstly, as an experiment under controlled conditions, we examine polymer particles of 6, 15, and 48 μm in diameter suspended in a 0.9% sodium chloride solution. Subsequently, we used K-562 cells and leukocytes suspended in a culture medium (RPMI-1640 supplemented) for a biological assay. As the main result, the [Formula: see text] is a function of the particle concentration. In addition, it shows a tendency with the particle size; regardless, it is limited to a volume fraction of 0.03 × 10(−4) to 58 × 10(−4). The [Formula: see text] is not significantly different between K-562 cells and leukocytes for most concentrations. On the other hand, the [Formula: see text] exhibits high applicability to retrieve a function that describes the concentration for each particle size, the K-562 cells, and leukocytes. The [Formula: see text] also shows a tendency with the particle size without limitation within the range tested, and it allows distinction between the K-562 and leukocytes in the 25 cells/µL to 400 cells/µL range. We achieved a simple method for determining an [Formula: see text] by unifying the parameters of an equivalent electrical circuit from data obtained with a conventional potentiostat. This simple approach is affordable for characterizing the population of non-adherent cells suspended in a cell culture medium. |
format | Online Article Text |
id | pubmed-9687723 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96877232022-11-25 Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies De León-Hernández, Alma Romero-Ornelas, Luisa Ramírez-Chavarría, Roberto G. Ramón-Gallegos, Eva Sánchez-Pérez, Celia Bioengineering (Basel) Article Analyzing the electrical double layer (EDL) in electrical impedance spectroscopy (EIS) measurement at low frequencies remains a challenging task for sensing purposes. In this work, we propose two approaches to deal with the EDL in measuring impedance for particles and non-adherent cells in an electrolytic suspension. The first approach is a simple procedure to compute a normalized electrical impedance spectrum named dispersed medium index ([Formula: see text]). The second is the EIS modeling through an equivalent electric circuit based on the so-called effective capacitance ([Formula: see text]), which unifies the EDL phenomena. Firstly, as an experiment under controlled conditions, we examine polymer particles of 6, 15, and 48 μm in diameter suspended in a 0.9% sodium chloride solution. Subsequently, we used K-562 cells and leukocytes suspended in a culture medium (RPMI-1640 supplemented) for a biological assay. As the main result, the [Formula: see text] is a function of the particle concentration. In addition, it shows a tendency with the particle size; regardless, it is limited to a volume fraction of 0.03 × 10(−4) to 58 × 10(−4). The [Formula: see text] is not significantly different between K-562 cells and leukocytes for most concentrations. On the other hand, the [Formula: see text] exhibits high applicability to retrieve a function that describes the concentration for each particle size, the K-562 cells, and leukocytes. The [Formula: see text] also shows a tendency with the particle size without limitation within the range tested, and it allows distinction between the K-562 and leukocytes in the 25 cells/µL to 400 cells/µL range. We achieved a simple method for determining an [Formula: see text] by unifying the parameters of an equivalent electrical circuit from data obtained with a conventional potentiostat. This simple approach is affordable for characterizing the population of non-adherent cells suspended in a cell culture medium. MDPI 2022-11-16 /pmc/articles/PMC9687723/ /pubmed/36421098 http://dx.doi.org/10.3390/bioengineering9110697 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article De León-Hernández, Alma Romero-Ornelas, Luisa Ramírez-Chavarría, Roberto G. Ramón-Gallegos, Eva Sánchez-Pérez, Celia Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies |
title | Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies |
title_full | Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies |
title_fullStr | Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies |
title_full_unstemmed | Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies |
title_short | Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies |
title_sort | effective capacitance from equivalent electrical circuit as a tool for monitoring non-adherent cell suspensions at low frequencies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9687723/ https://www.ncbi.nlm.nih.gov/pubmed/36421098 http://dx.doi.org/10.3390/bioengineering9110697 |
work_keys_str_mv | AT deleonhernandezalma effectivecapacitancefromequivalentelectricalcircuitasatoolformonitoringnonadherentcellsuspensionsatlowfrequencies AT romeroornelasluisa effectivecapacitancefromequivalentelectricalcircuitasatoolformonitoringnonadherentcellsuspensionsatlowfrequencies AT ramirezchavarriarobertog effectivecapacitancefromequivalentelectricalcircuitasatoolformonitoringnonadherentcellsuspensionsatlowfrequencies AT ramongallegoseva effectivecapacitancefromequivalentelectricalcircuitasatoolformonitoringnonadherentcellsuspensionsatlowfrequencies AT sanchezperezcelia effectivecapacitancefromequivalentelectricalcircuitasatoolformonitoringnonadherentcellsuspensionsatlowfrequencies |